Literature DB >> 17117780

Using human and model performance to compare MRI reconstructions.

M Dylan Tisdall1, M Stella Atkins.   

Abstract

Magnetic resonance imaging (MRI) reconstruction techniques are often validated with signal-to-noise ratio (SNR), contrast-to-noise ratio, and mean-to-standard-deviation ratio measured on example images. We present human and model observers as a novel approach to evaluating reconstructions for low-SNR magnetic resonance (MR) images. We measured human and channelized Hotelling observers in a two-alternative forced-choice signal-known-exactly detection task on synthetic MR images. We compared three reconstructions: magnitude, wavelet-based denoising, and phase-corrected real. Human observers performed approximately equally using all three reconstructions. The model observer showed very close agreement with the humans over the range of images. These results contradict previous predictions in the literature based on SNR. Thus, we propose that human observer studies are important for validating MRI reconstructions. The model's performance indicates that it may provide an alternative to human studies.

Entities:  

Mesh:

Year:  2006        PMID: 17117780     DOI: 10.1109/TMI.2006.881374

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  Exact confidence intervals for channelized Hotelling observer performance in image quality studies.

Authors:  Adam Wunderlich; Frederic Noo; Brandon D Gallas; Marta E Heilbrun
Journal:  IEEE Trans Med Imaging       Date:  2014-09-26       Impact factor: 10.048

3.  Automated reference-free detection of motion artifacts in magnetic resonance images.

Authors:  Thomas Küstner; Annika Liebgott; Lukas Mauch; Petros Martirosian; Fabian Bamberg; Konstantin Nikolaou; Bin Yang; Fritz Schick; Sergios Gatidis
Journal:  MAGMA       Date:  2017-09-20       Impact factor: 2.310

4.  Compressive sensing in medical imaging.

Authors:  Christian G Graff; Emil Y Sidky
Journal:  Appl Opt       Date:  2015-03-10       Impact factor: 1.980

5.  A simple method for rectified noise floor suppression: Phase-corrected real data reconstruction with application to diffusion-weighted imaging.

Authors:  Douglas E Prah; Eric S Paulson; Andrew S Nencka; Kathleen M Schmainda
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

6.  Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: impact of radiation dose and reconstruction algorithms.

Authors:  Lifeng Yu; Shuai Leng; Lingyun Chen; James M Kofler; Rickey E Carter; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

7.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

  7 in total