Antonio Oliveri1, Nigel Howarth2, Pierre Alain Gevenois3, Denis Tack4. 1. Université libre de Bruxelles, School of Medicine, Route de Lennik 808, 1070, Brussels, Belgium. 2. Department of Radiology, Clinique des Grangettes, 7 Chemin des Grangettes, 1224, Chêne-Bougeries, Switzerland. 3. Department of Radiology, Hôpital Erasme, Route de Lennik 808, 1070, Brussels, Belgium. 4. Department of Radiology, EpiCURA, Clinique Louis Caty, rue Louis Caty 136, 7331, Baudour, Belgium. denis.tack@skynet.be.
Abstract
PURPOSE: To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. MATERIALS AND METHODS: This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific "paediatric brain CT" procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. RESULTS: Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from <0.001 to 0.031) in both hospitals and remained unchanged during the third audit (P ranging from 0.114 to 0.999). CONCLUSION: Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. KEY POINTS: • Compliance with CT procedures is operator-dependent and not perfect. • Compliance differs between procedures and hospitals, even within a unified department. • Compliance is improved through audits followed by communication to the stakeholders. • This improvement is sustainable over a one-year period.
PURPOSE: To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. MATERIALS AND METHODS: This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific "paediatric brain CT" procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. RESULTS: Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from <0.001 to 0.031) in both hospitals and remained unchanged during the third audit (P ranging from 0.114 to 0.999). CONCLUSION: Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. KEY POINTS: • Compliance with CT procedures is operator-dependent and not perfect. • Compliance differs between procedures and hospitals, even within a unified department. • Compliance is improved through audits followed by communication to the stakeholders. • This improvement is sustainable over a one-year period.
Authors: Eric P Tamm; X John Rong; Dianna D Cody; Randy D Ernst; Nancy E Fitzgerald; Vikas Kundra Journal: Radiographics Date: 2011-10-03 Impact factor: 5.333
Authors: Hedvig Hricak; David J Brenner; S James Adelstein; Donald P Frush; Eric J Hall; Roger W Howell; Cynthia H McCollough; Fred A Mettler; Mark S Pearce; Orhan H Suleiman; James H Thrall; Louis K Wagner Journal: Radiology Date: 2010-12-16 Impact factor: 11.105
Authors: Catherine A Logan; Brienne D Cressey; Roger Y Wu; Adam J Janicki; Cyril X Chen; Meena L Bolourchi; Jessica L Hodnett; John D Stratigis; William C Mackey; David G Fairchild Journal: J Surg Educ Date: 2011-08-27 Impact factor: 2.891
Authors: David S Gierada; Kavita Garg; Hrudaya Nath; Diane C Strollo; Richard M Fagerstrom; Melissa B Ford Journal: AJR Am J Roentgenol Date: 2009-08 Impact factor: 3.959
Authors: Alice B Smith; William P Dillon; Benison C Lau; Robert Gould; Francis R Verdun; Edward B Lopez; Max Wintermark Journal: Radiology Date: 2008-03-27 Impact factor: 11.105