Literature DB >> 18677487

Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Anno Graser1, Thorsten R C Johnson, Hersh Chandarana, Michael Macari.   

Abstract

Dual energy CT (DECT) is a new technique that allows differentiation of materials and tissues based on CT density values derived from two synchronous CT acquisitions at different tube potentials. With the introduction of a new dual source CT system, this technique can now be used routinely in abdominal imaging. Potential clinical applications include evaluation of renal masses, liver lesions, urinary calculi, small bowel, pancreas, and adrenal glands. In CT angiography of abdominal aortic aneurysms, dual energy CT techniques can be used to remove bones from the datasets, and virtual unenhanced images allow differentiation of contrast agent from calcifying thrombus in patients with endovascular stents. This review describes potential applications, practical guidelines, and limitations of dual energy CT in the abdomen.

Entities:  

Mesh:

Year:  2008        PMID: 18677487     DOI: 10.1007/s00330-008-1122-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  40 in total

1.  Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions.

Authors:  Alla M Rozenblit; Michael Patlas; Ayala T Rosenbaum; Takao Okhi; Frank J Veith; Mitchell P Laks; Zina J Ricci
Journal:  Radiology       Date:  2003-04-03       Impact factor: 11.105

2.  Surgically staged focal liver lesions: accuracy and reproducibility of dual-phase helical CT for detection and characterization.

Authors:  Ihab R Kamel; Michael A Choti; Karen M Horton; H J V Braga; Bernard A Birnbaum; Elliot K Fishman; Richard E Thompson; David A Bluemke
Journal:  Radiology       Date:  2003-06       Impact factor: 11.105

3.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

4.  Evaluation of bowel distention and bowel wall appearance by using neutral oral contrast agent for multi-detector row CT.

Authors:  Alec J Megibow; James S Babb; Elizabeth M Hecht; Jennie J Cho; Carmela Houston; Michael M Boruch; Archie B Williams
Journal:  Radiology       Date:  2005-11-17       Impact factor: 11.105

5.  Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study.

Authors:  Sanjeeva P Kalva; Dushyant V Sahani; Peter F Hahn; Sanjay Saini
Journal:  J Comput Assist Tomogr       Date:  2006 May-Jun       Impact factor: 1.826

6.  Multiphasic renal CT: comparison of renal mass enhancement during the corticomedullary and nephrographic phases.

Authors:  B A Birnbaum; J E Jacobs; P Ramchandani
Journal:  Radiology       Date:  1996-09       Impact factor: 11.105

Review 7.  Kidney stones: pathophysiology and medical management.

Authors:  Orson W Moe
Journal:  Lancet       Date:  2006-01-28       Impact factor: 79.321

8.  Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease.

Authors:  Hans Scheffel; Paul Stolzmann; Thomas Frauenfelder; Thomas Schertler; Lotus Desbiolles; Sebastian Leschka; Borut Marincek; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-12       Impact factor: 6.016

9.  Comparison of unenhanced CT and chemical shift MRI in evaluating lipid-rich adrenal adenomas.

Authors:  Gary M Israel; Melvyn Korobkin; Chun Wang; Elizabeth N Hecht; Glenn A Krinsky
Journal:  AJR Am J Roentgenol       Date:  2004-07       Impact factor: 3.959

10.  Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience.

Authors:  Anno Graser; Thorsten R C Johnson; Markus Bader; Michael Staehler; Nicolas Haseke; Konstantin Nikolaou; Maximilian F Reiser; Christian G Stief; Christoph R Becker
Journal:  Invest Radiol       Date:  2008-02       Impact factor: 6.016

View more
  105 in total

1.  Usefulness of dual-energy CT scanning at 80 kVp for identifying hilar and mediastinal structures: evaluation of contrast enhancement of the pulmonary vessels and lymph nodes.

Authors:  Ayano Imafuji; Masaki Hara; Shigeru Sasaki; Toshinao Arakawa; Yoshiyuki Ozawa; Yuta Shibamoto
Journal:  Jpn J Radiol       Date:  2011-12-03       Impact factor: 2.374

2.  Spectral Hounsfield units: a new radiological concept.

Authors:  Michael Anthony Hurrell; Anthony Philip Howard Butler; Nicholas James Cook; Philip Howard Butler; J Paul Ronaldson; Rafidah Zainon
Journal:  Eur Radiol       Date:  2011-12-02       Impact factor: 5.315

3.  Differentiation of hemorrhage from iodinated contrast in different intracranial compartments using dual-energy head CT.

Authors:  C M Phan; A J Yoo; J A Hirsch; R G Nogueira; R Gupta
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

4.  Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements.

Authors:  Mark Lewis; Karen Reid; Andoni P Toms
Journal:  Skeletal Radiol       Date:  2012-06-09       Impact factor: 2.199

5.  Preliminary experience with abdominal dual-energy CT (DECT): true versus virtual nonenhanced images of the liver.

Authors:  C N De Cecco; V Buffa; S Fedeli; A Vallone; R Ruopoli; M Luzietti; V Miele; M Rengo; M Maurizi Enrici; P Fina; A Laghi; V David
Journal:  Radiol Med       Date:  2010-09-17       Impact factor: 3.469

6.  Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study.

Authors:  Christoph Karlo; Arno Lauber; Robert Paul Götti; Stephan Baumüller; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Bernhard Schmidt; Borut Marincek; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-08-15       Impact factor: 5.315

7.  Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study.

Authors:  Long-Jiang Zhang; Jin Peng; Sheng-Yong Wu; Z Jane Wang; Xin-Sheng Wu; Chang-Sheng Zhou; Xue-Man Ji; Guang-Ming Lu
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

8.  Iodine quantification with dual-energy CT: phantom study and preliminary experience with VX2 residual tumour in rabbits after radiofrequency ablation.

Authors:  Y Li; G Shi; S Wang; S Wang; R Wu
Journal:  Br J Radiol       Date:  2013-07-24       Impact factor: 3.039

9.  Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study.

Authors:  C L Brown; R P Hartman; O P Dzyubak; N Takahashi; A Kawashima; C H McCollough; M R Bruesewitz; A M Primak; J G Fletcher
Journal:  Eur Radiol       Date:  2009-01-20       Impact factor: 5.315

10.  Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography.

Authors:  Masaki Katsura; Jiro Sato; Masaaki Akahane; Taku Tajima; Toshihiro Furuta; Harushi Mori; Osamu Abe
Journal:  Neuroradiology       Date:  2018-08-24       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.