Literature DB >> 21464527

MicroCT with energy-resolved photon-counting detectors.

X Wang1, D Meier, S Mikkelsen, G E Maehlum, D J Wagenaar, B M W Tsui, B E Patt, E C Frey.   

Abstract

The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with K-absorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21464527      PMCID: PMC3095970          DOI: 10.1088/0031-9155/56/9/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors.

Authors:  Katsuyuki Taguchi; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; William C Barber
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Photon counting computed tomography: concept and initial results.

Authors:  Polad M Shikhaliev; Tong Xu; Sabee Molloi
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

3.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

4.  Multienergy photon-counting K-edge imaging: potential for improved luminal depiction in vascular imaging.

Authors:  Sebastian Feuerlein; Ewald Roessl; Roland Proksa; Gerhard Martens; Oliver Klass; Martin Jeltsch; Volker Rasche; Hans-Juergen Brambs; Martin H K Hoffmann; Jens-Peter Schlomka
Journal:  Radiology       Date:  2008-10-10       Impact factor: 11.105

5.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

6.  Material separation in x-ray CT with energy resolved photon-counting detectors.

Authors:  Xiaolan Wang; Dirk Meier; Katsuyuki Taguchi; Douglas J Wagenaar; Bradley E Patt; Eric C Frey
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles.

Authors:  David P Cormode; Ewald Roessl; Axel Thran; Torjus Skajaa; Ronald E Gordon; Jens-Peter Schlomka; Valentin Fuster; Edward A Fisher; Willem J M Mulder; Roland Proksa; Zahi A Fayad
Journal:  Radiology       Date:  2010-07-28       Impact factor: 11.105

8.  Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.

Authors:  Stefano Del Sordo; Leonardo Abbene; Ezio Caroli; Anna Maria Mancini; Andrea Zappettini; Pietro Ubertini
Journal:  Sensors (Basel)       Date:  2009-05-12       Impact factor: 3.576

  8 in total
  22 in total

1.  Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: a feasibility study.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Phys Med Biol       Date:  2012-07-06       Impact factor: 3.609

2.  Model-based material decomposition with a penalized nonlinear least-squares CT reconstruction algorithm.

Authors:  Steven Tilley; Wojciech Zbijewski; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-01-22       Impact factor: 3.609

3.  Experimental comparison of empirical material decomposition methods for spectral CT.

Authors:  Kevin C Zimmerman; Taly Gilat Schmidt
Journal:  Phys Med Biol       Date:  2015-03-27       Impact factor: 3.609

4.  Optimization of K-edge imaging with spectral CT.

Authors:  Peng He; Biao Wei; Wenxiang Cong; Ge Wang
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

5.  Breast composition measurement with a cadmium-zinc-telluride based spectral computed tomography system.

Authors:  Huanjun Ding; Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

6.  Breast tissue decomposition with spectral distortion correction: a postmortem study.

Authors:  Huanjun Ding; Bo Zhao; Pavlo Baturin; Farnaz Behroozi; Sabee Molloi
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

7.  High spectral and spatial resolution X-ray transmission radiography and tomography using a Color X-ray Camera.

Authors:  Matthieu N Boone; Jan Garrevoet; Pieter Tack; Oliver Scharf; David P Cormode; Denis Van Loo; Elin Pauwels; Manuel Dierick; Laszlo Vincze; Luc Van Hoorebeke
Journal:  Nucl Instrum Methods Phys Res A       Date:  2014-01-21       Impact factor: 1.455

8.  Energy-discriminative performance of a spectral micro-CT system.

Authors:  Peng He; Hengyong Yu; James Bennett; Paul Ronaldson; Rafidah Zainon; Anthony Butler; Phil Butler; Biao Wei; Ge Wang
Journal:  J Xray Sci Technol       Date:  2013       Impact factor: 1.535

9.  A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data.

Authors:  Taly Gilat Schmidt; Rina Foygel Barber; Emil Y Sidky
Journal:  IEEE Trans Med Imaging       Date:  2017-04-24       Impact factor: 10.048

10.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.