Literature DB >> 24004864

Energy-discriminative performance of a spectral micro-CT system.

Peng He1, Hengyong Yu, James Bennett, Paul Ronaldson, Rafidah Zainon, Anthony Butler, Phil Butler, Biao Wei, Ge Wang.   

Abstract

Experiments were performed to evaluate the energy-discriminative performance of a spectral (multi-energy) micro-CT system. The system, designed by MARS (Medipix All Resolution System) Bio-Imaging Ltd. (Christchurch, New Zealand), employs a photon-counting energy-discriminative detector technology developed by CERN (European Organization for Nuclear Research). We used the K-edge attenuation characteristics of some known materials to calibrate the detector's photon energy discrimination. For tomographic analysis, we used the compressed sensing (CS) based ordered-subset simultaneous algebraic reconstruction techniques (OS-SART) to reconstruct sample images, which is effective to reduce noise and suppress artifacts. Unlike conventional CT, the principal component analysis (PCA) method can be applied to extract and quantify additional attenuation information from a spectral CT dataset. Our results show that the spectral CT has a good energy-discriminative performance and provides more attenuation information than the conventional CT.

Entities:  

Mesh:

Year:  2013        PMID: 24004864      PMCID: PMC3824963          DOI: 10.3233/XST-130382

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  13 in total

1.  Convergence studies on iterative algorithms for image reconstruction.

Authors:  Ming Jiang; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2003-05       Impact factor: 10.048

2.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors.

Authors:  Katsuyuki Taguchi; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; William C Barber
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.

Authors:  E Roessl; R Proksa
Journal:  Phys Med Biol       Date:  2007-07-17       Impact factor: 3.609

4.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

5.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

6.  Embedded soft-tissue image mechanism of a small animal shell with synchrotron-based micro-CT.

Authors:  Donepudi V Rao; Roberto Cesareo; Antonio Brunetti; Tako Akatsuka; Tetsuya Yuasa; Tohoru Takeda; Giovanni E Gigante
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

7.  Simultaneous algebraic reconstruction technique (SART): a superior implementation of the art algorithm.

Authors:  A H Andersen; A C Kak
Journal:  Ultrason Imaging       Date:  1984-01       Impact factor: 1.578

8.  Selective iodine imaging using K-edge energies in computerized x-ray tomography.

Authors:  S J Riederer; C A Mistretta
Journal:  Med Phys       Date:  1977 Nov-Dec       Impact factor: 4.071

9.  Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study.

Authors:  Elisabeth Schültke; Stefan Fiedler; Christian Nemoz; Lissa Ogieglo; Michael E Kelly; Paul Crawford; Francois Esteve; Thierry Brochard; Michel Renier; Herwig Requardt; Geraldine Le Duc; Bernhard Juurlink; Kotoo Meguro
Journal:  Eur J Radiol       Date:  2009-02-23       Impact factor: 3.528

10.  Compressed sensing based interior tomography.

Authors:  Hengyong Yu; Ge Wang
Journal:  Phys Med Biol       Date:  2009-04-15       Impact factor: 3.609

View more
  4 in total

1.  Evaluation of an Analytic Reconstruction Method as a Platform for Spectral Cone-beam CT.

Authors:  Huihua Kong; Rui Liu; Jinxiao Pan; Hengyong Yu
Journal:  IEEE Access       Date:  2018-03-28       Impact factor: 3.367

2.  Medipix-based Spectral Micro-CT.

Authors:  Hengyong Yu; Qiong Xu; Peng He; James Bennett; Raja Amir; Bruce Dobbs; Xuanqin Mou; Biao Wei; Anthony Butler; Phillip Butler; Ge Wang
Journal:  CT Li Lun Yu Ying Yong Yan Jiu       Date:  2012-12

3.  A framelet-based iterative maximum-likelihood reconstruction algorithm for spectral CT.

Authors:  Yingmei Wang; Ge Wang; Shuwei Mao; Wenxiang Cong; Zhilong Ji; Jian-Feng Cai; Yangbo Ye
Journal:  Inverse Probl       Date:  2016-10-18       Impact factor: 2.407

Review 4.  Microcomputed tomography: approaches and applications in bioengineering.

Authors:  Joel D Boerckel; Devon E Mason; Anna M McDermott; Eben Alsberg
Journal:  Stem Cell Res Ther       Date:  2014-12-29       Impact factor: 6.832

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.