A comparative evaluation of three hydrophones and a numerical model in high intensity focused ultrasound fields.

Julian Haller1, Klaus-Vitold Jenderka, Gianni Durando, Adam Shaw.   

Abstract

The pressure fields of two different high intensity focused ultrasound (HIFU) transducers operated in burst mode were measured at acoustical power levels of 25 and 50 W (continuous wave equivalent) with three different hydrophones: A fiber-optic displacement sensor, a commercial HIFU needle hydrophone, and a prototype of a membrane hydrophone with a protective coating against cavitation effects. Additionally, the fields were modeled using a freely available simulations software package. The measured waveforms, the peak pressure profiles, as well as the spatial-peak temporal-average intensities from the different devices and from the modeling are compared and possible reasons for differences are discussed. The results clearly show that reliable pressure measurements in HIFU fields remain a difficult task concerning both the reliability of the measured values and the robustness of the sensors used: Only the fiber-optic hydrophone survived all four exposure regimes and the measured spatial-peak temporal-average intensities varied by a factor of up to 1.5 between the measurements and the modeling and between the measurements among themselves.
© 2012 Acoustical Society of America

Year:  2012        PMID: 22352487     DOI: 10.1121/1.3675003

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  10 in total

1.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Improved measurement of acoustic output using complex deconvolution of hydrophone sensitivity.

Authors:  Keith A Wear; Paul M Gammell; Subha Maruvada; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

3.  Variation of High-Intensity Therapeutic Ultrasound (HITU) Pressure Field Characterization: Effects of Hydrophone Choice, Nonlinearity, Spatial Averaging and Complex Deconvolution.

Authors:  Yunbo Liu; Keith A Wear; Gerald R Harris
Journal:  Ultrasound Med Biol       Date:  2017-07-21       Impact factor: 2.998

4.  Correction for frequency-dependent hydrophone response to nonlinear pressure waves using complex deconvolution and rarefactional filtering: application with fiber optic hydrophones.

Authors:  Keith Wear; Yunbo Liu; Paul M Gammell; Subha Maruvada; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-01       Impact factor: 2.725

5.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

6.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

7.  Pressure Pulse Distortion by Needle and Fiber-Optic Hydrophones due to Nonuniform Sensitivity.

Authors:  Keith A Wear; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-02       Impact factor: 2.725

8.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Needle Hydrophones: Predictions From Four Theoretical Forms Compared With Measurements.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-13       Impact factor: 2.725

9.  Increased light penetration due to ultrasound-induced air bubbles in optical scattering media.

Authors:  Haemin Kim; Jin Ho Chang
Journal:  Sci Rep       Date:  2017-11-23       Impact factor: 4.379

10.  A rapid and non-invasive method for measuring the peak positive pressure of HIFU fields by a laser beam.

Authors:  Hua Wang; Deping Zeng; Ziguang Chen; Zengtao Yang
Journal:  Sci Rep       Date:  2017-04-12       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.