A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

R Zotova1, J Vassileva, J Hristova, M Pirinen, H Järvinen.   

Abstract

OBJECTIVES: A national study on patient dose values in interventional radiology and cardiology was performed in order to assess current practice in Bulgaria, to estimate the typical patient doses and to propose reference levels for the most common procedures.
METHODS: Fifteen units and more than 1,000 cases were included. Average values of the measured parameters for three procedures-coronary angiography (CA), combined procedure (CA + PCI) and lower limb arteriography (LLA)--were compared with data published in the literature.
RESULTS: Substantial variations were observed in equipment and procedure protocols used. This resulted in variations in patient dose: air-kerma area product ranges were 4-339, 6-1,003 and 0.2-288 Gy cm(2) for CA, CA + PCI and LLA respectively. Reference levels for air kerma-area product were proposed: 40 Gy cm(2) for CA, 140 Gy cm(2) for CA + PCI and 45 Gy cm(2) for LLA. Auxiliary reference intervals were proposed for other dose-related parameters: fluoroscopy time, number of images and entrance surface air kerma rate in fluoroscopy and cine mode.
CONCLUSIONS: There is an apparent necessity for improvement in the classification of peripheral procedures and for standardisation of the protocols applied. It is important that patient doses are routinely recorded and compared with reference levels. KEY POINTS: • Patient doses in interventional radiology are high and vary greatly • Better standardisation of procedures and techniques is needed to improve practice • Dose reference levels for most common procedures are proposed.

Entities:  

Mesh:

Year:  2012        PMID: 22350490     DOI: 10.1007/s00330-012-2386-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  12 in total

1.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

2.  Reference levels at European level for cardiac interventional procedures.

Authors:  R Padovani; E Vano; A Trianni; C Bokou; H Bosmans; D Bor; J Jankowski; P Torbica; K Kepler; A Dowling; C Milu; V Tsapaki; D Salat; J Vassileva; K Faulkner
Journal:  Radiat Prot Dosimetry       Date:  2008-02-29       Impact factor: 0.972

3.  Patient dosimetry for x rays used in medical imaging.

Authors: 
Journal:  J ICRU       Date:  2005-12

4.  A pilot study exploring the possibility of establishing guidance levels in x-ray directed interventional procedures.

Authors:  S Balter; D L Miller; E Vano; P Ortiz Lopez; G Bernardi; E Cotelo; K Faulkner; R Nowotny; R Padovani; A Ramirez
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

5.  Estimation of effective dose in some digital angiographic and interventional procedures.

Authors:  R Ruiz Cruces; J García-Granados; F J Diaz Romero; J Hernández Armas
Journal:  Br J Radiol       Date:  1998-01       Impact factor: 3.039

6.  Patient peak skin doses from cardiac interventional procedures.

Authors:  D Zontar; D Kuhelj; D Skrk; U Zdesar
Journal:  Radiat Prot Dosimetry       Date:  2010-02-05       Impact factor: 0.972

7.  Patient dose in interventional radiology: a European survey.

Authors:  E Vano; H Järvinen; A Kosunen; R Bly; J Malone; A Dowling; A Larkin; R Padovani; H Bosmans; O Dragusin; W Jaschke; P Torbica; C Back; A Schreiner; C Bokou; S Kottou; V Tsapaki; J Jankowski; S Papierz; J Domienik; A Werduch; D Nikodemova; D Salat; K Kepler; M D Bor; J Vassileva; R Borisova; S Pellet; R H Corbett
Journal:  Radiat Prot Dosimetry       Date:  2008-02-20       Impact factor: 0.972

8.  Diagnostic reference levels in angiography and interventional radiology: a Belgian multi-centre study.

Authors:  F Bleeser; M-T Hoornaert; K Smans; L Struelens; N Buls; D Berus; P Clerinx; L Hambach; F Malchair; H Bosmans
Journal:  Radiat Prot Dosimetry       Date:  2008-02-18       Impact factor: 0.972

9.  Proposed preliminary diagnostic reference levels for three common interventional cardiology procedures in Ireland.

Authors:  C D'Helft; A McGee; L Rainford; S McFadden; J Winder; C Hughes; P C Brennan
Journal:  Radiat Prot Dosimetry       Date:  2008-04-16       Impact factor: 0.972

10.  Patient dose values in interventional radiology.

Authors:  E Vañó; L González; J M Fernández; E Guibelalde
Journal:  Br J Radiol       Date:  1995-11       Impact factor: 3.039

View more
  5 in total

1.  Patient radiation doses and reference levels in pediatric interventional radiology.

Authors:  Bouchra Habib Geryes; Adeline Bak; Julie Lachaux; Augustin Ozanne; Nathalie Boddaert; Francis Brunelle; Olivier Naggara; Guillaume Saliou
Journal:  Eur Radiol       Date:  2017-02-16       Impact factor: 5.315

2.  Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France.

Authors:  Cécile Etard; Emeline Bigand; Cécile Salvat; Vincent Vidal; Jean Paul Beregi; Amaury Hornbeck; Joël Greffier
Journal:  Eur Radiol       Date:  2017-03-13       Impact factor: 5.315

3.  Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

Authors:  R Ruiz-Cruces; E Vano; F Carrera-Magariño; F Moreno-Rodriguez; M M Soler-Cantos; M Canis-Lopez; J Hernández-Armas; F J Diaz-Romero; F Rosales-Espizua; J M Fernandez-Soto; R Sanchez-Casanueva; A Martin-Palanca; M Perez-Martinez; A Gil-Agudo; M A Zarca-Diaz; V Parra-Osorio; J J Muñoz Ruiz-Canela; T Moreno-Sanchez; A Lopez-Medina; C Moreno-Saiz; P Galan-Montenegro; J J Gallego-Beuter; M Gonzalez-de-Garay; J C Zapata-Jimenez; J M Pastor-Vega; S Cañete
Journal:  Eur Radiol       Date:  2016-07-06       Impact factor: 5.315

4.  Retrospective study of patients radiation dose during cardiac catheterization procedures.

Authors:  Beverley Osei; Lu Xu; Amanda Johnston; Sara Darko; Johnson Darko; Ernest Osei
Journal:  Br J Radiol       Date:  2019-05-14       Impact factor: 3.039

5.  Patient skin dose measurements using a cable free system MOSFETs based in fluoroscopically guided percutaneous vertebroplasty, percutaneous disc decompression, radiofrequency medial branch neurolysis, and endovascular critical limb ischemia.

Authors:  Maria D Falco; Salvatore Masala; Matteo Stefanini; Roberto Fiori; Roberto Gandini; Paolo Bagalà; Daniele Morosetti; Eros Calabria; Alessia Tonnetti; Gianluca Verona-Rinati; Riccardo Santoni; Giovanni Simonetti
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.