Literature DB >> 8542229

Patient dose values in interventional radiology.

E Vañó1, L González, J M Fernández, E Guibelalde.   

Abstract

Large exposures incurred in interventional radiology procedures make it advisable to establish reference dose values. These dose values should be quoted in quantities representative of the radiological risk to the patient. In Spain, measurement methods were developed to comply with the European Directive on Patient Protection. Dose-area product and, when feasible, surface dose using thermoluminescent dosimetry chips were measured. Both approaches are discussed, as well as their potential use in patient protection programmes. Initial results are presented for a sample of 680 patients in 10 hospital centres in Spain. Mean, median and range are reported for some specific procedures. Mean values of 8750, 6651, 6663, 9292 and 6816 cGy cm2 are reported for percutaneous transluminal coronary angioplasty, coronary angiography, low extremity, renal and cerebral arteriographies, respectively.

Entities:  

Mesh:

Year:  1995        PMID: 8542229     DOI: 10.1259/0007-1285-68-815-1215

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  10 in total

1.  Radiation dose and risk from fluoroscopically guided percutaneous transluminal angioplasty and stenting in the abdominal region.

Authors:  John Stratakis; John Damilakis; Dimitrios Tsetis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2007-03-27       Impact factor: 5.315

2.  Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters.

Authors:  T Moritake; Y Matsumaru; T Takigawa; K Nishizawa; A Matsumura; K Tsuboi
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-21       Impact factor: 3.825

3.  A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

Authors:  R Zotova; J Vassileva; J Hristova; M Pirinen; H Järvinen
Journal:  Eur Radiol       Date:  2012-02-19       Impact factor: 5.315

4.  Optimization and audit of radiation dose during percutaneous transluminal coronary angioplasty.

Authors:  Roshan S Livingstone; B S Timothy Peace; Sunil Chandy; Paul V George; Purendra Pati
Journal:  J Med Phys       Date:  2007-10

5.  Reduction of radiation doses to patients and staff during endoscopic retrograde cholangiopancreatography.

Authors:  Abdelmoneim Sulieman; Georgios Paroutoglou; Andreas Kapsoritakis; Anargeyros Kapatenakis; Spiros Potamianos; Marianna Vlychou; Kiki Theodorou
Journal:  Saudi J Gastroenterol       Date:  2011 Jan-Feb       Impact factor: 2.485

6.  Evaluation of radiation dose to patients undergoing interventional radiology procedures at Ramathibodi Hospital, Thailand.

Authors:  J Urairat; S Asavaphatiboon; S Singhara Na Ayuthaya; N Pongnapang
Journal:  Biomed Imaging Interv J       Date:  2011-07-01

Review 7.  Practice of ALARA in the pediatric interventional suite.

Authors:  Bairbre Connolly; John Racadio; Richard Towbin
Journal:  Pediatr Radiol       Date:  2006-09

8.  An Evaluation of the Organ Dose Received by Cardiologists Arising From Angiography Examinations in Educational Hospital in Rasht.

Authors:  Akram Shoshtary; Jalil Pirayesh Islamian; Mohsen Asadinezhad; Alireza Sadremomtaz
Journal:  Glob J Health Sci       Date:  2015-11-18

9.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01

10.  Niveles de referencia de dosis para adultos en procedimientos de cardiología intervencionista en Ecuador.

Authors:  Nadia A González-López; Katerine M Parra-Riofrío; Mario A Batista-Zaldívar; Edison Carrillo-Vallejo; Vilma N Yanchapanta-Bastidas
Journal:  Arch Cardiol Mex       Date:  2021-11-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.