Literature DB >> 18310612

Reference levels at European level for cardiac interventional procedures.

R Padovani1, E Vano, A Trianni, C Bokou, H Bosmans, D Bor, J Jankowski, P Torbica, K Kepler, A Dowling, C Milu, V Tsapaki, D Salat, J Vassileva, K Faulkner.   

Abstract

In interventional cardiology, a wide variation in patient dose for the same type of procedure has been recognised by different studies. Variation is almost due to procedure complexity, equipment performance, procedure protocol and operator skill. The SENTINEL consortium has performed a survey in nine european centres collecting information on near 2000 procedures, and a new set of reference levels (RLs) for coronary angiography and angioplasty and diagnostic electrophysiology has been assessed for air kerma-area product: 45, 85 and 35 Gy cm2, effective dose: 8, 15 and 6 mSv, cumulative dose at interventional reference point: 650 and 1500 mGy, fluoroscopy time: 6.5, 15.5 and 21 min and cine frames: 700 and 1000 images, respectively. Because equipment performance and set-up are the factors contributing to patient dose variability, entrance surface air kerma for fluoroscopy, 13 mGy min(-1), and image acquisition, 0.10 mGy per frame, have also been proposed in the set of RLs.

Entities:  

Mesh:

Year:  2008        PMID: 18310612     DOI: 10.1093/rpd/ncn039

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  13 in total

1.  Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study.

Authors:  Uwe Häusler; Renate Czarwinski; Gunnar Brix
Journal:  Eur Radiol       Date:  2009-04-07       Impact factor: 5.315

2.  Clinical apparatus for the reduction of dose area product for patients undergoing x-ray catheterization.

Authors:  Normand Robert; Kristina N Watt; Sophie Rochette; Lionel Desponds; Régis Vaillant; John A Rowlands
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

3.  Reference levels and patient doses in interventional cardiology procedures in Greece.

Authors:  George Simantirakis; Christina Koukorava; Maria Kalathaki; Christos Pafilis; Ioannis Kaisas; Sotirios Economides; Costas J Hourdakis; Vassiliki Kamenopoulou; Evaggelos Georgiou
Journal:  Eur Radiol       Date:  2013-04-06       Impact factor: 5.315

4.  The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair.

Authors:  Rita Fossaceca; Marco Brambilla; Giuseppe Guzzardi; Paolo Cerini; Alessandra Renghi; Serena Valzano; Piero Brustia; Alessandro Carriero
Journal:  Eur Radiol       Date:  2012-05-23       Impact factor: 5.315

5.  A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

Authors:  R Zotova; J Vassileva; J Hristova; M Pirinen; H Järvinen
Journal:  Eur Radiol       Date:  2012-02-19       Impact factor: 5.315

6.  Radiation doses during cardiac catheterisation procedures in India: a multicentre study: Radiation dose study.

Authors:  Vijayakumar Subban; Sophie Amelot; Suma M Victor; Anil Potdar; Vishawanath Yadav; Tejas Patel; Sanjay Shah; Thomas Alexander; Balakumaran Jeyakumaran; Juno Angel; Mullasari S Ajit
Journal:  AsiaIntervention       Date:  2020-07-20

7.  Occupational cataracts and lens opacities in interventional cardiology (O'CLOC study): are X-Rays involved? Radiation-induced cataracts and lens opacities.

Authors:  Sophie Jacob; Morgane Michel; Christian Spaulding; Serge Boveda; Olivier Bar; Antoine P Brézin; Maté Streho; Carlo Maccia; Pascale Scanff; Dominique Laurier; Marie-Odile Bernier
Journal:  BMC Public Health       Date:  2010-09-08       Impact factor: 3.295

8.  Retrospective study of patients radiation dose during cardiac catheterization procedures.

Authors:  Beverley Osei; Lu Xu; Amanda Johnston; Sara Darko; Johnson Darko; Ernest Osei
Journal:  Br J Radiol       Date:  2019-05-14       Impact factor: 3.039

9.  Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals.

Authors:  James A Crowhurst; Mark Whitby; David Thiele; Toni Halligan; Adam Westerink; Suzanne Crown; Jillian Milne
Journal:  J Med Radiat Sci       Date:  2014-08-04

10.  Novel X-ray image noise reduction technology reduces patient radiation dose while maintaining image quality in coronary angiography.

Authors:  T Ten Cate; M van Wely; H Gehlmann; M Mauti; C Camaro; N Reifart; H Suryapranata; M J de Boer
Journal:  Neth Heart J       Date:  2015-11       Impact factor: 2.380

View more