Patient peak skin doses from cardiac interventional procedures.

D Zontar1, D Kuhelj, D Skrk, U Zdesar.   

Abstract

Interventional cardiac procedures not only lead to significant effective doses for the patient but also can potentially cause deterministic effects on the patient's skin. Information about the peak (maximal) skin doses (PSD) received by patients during percutaneous transluminal coronary angioplasty procedures were collected from three cardiac catheter rooms. Cumulative dose at the interventional reference point (CD(IRP)) was collected for 161 patients and for 16 patients PSD was determined using Gafchromic dosimetry films. The comparison showed that CD(IRP) readings give a useful but conservative estimation of patient peak skin dose as it can lead to a significant overestimation. The median and third quartile values of CD(IRP) were 0.64 and 0.92 Gy, respectively. The 2 Gy threshold for deterministic effects was exceeded in nine patients. A good correlation was found between CD(IRP) and kerma area product measurements while the correlation with fluorography time was very weak.

Entities:  

Mesh:

Year:  2010        PMID: 20139269     DOI: 10.1093/rpd/ncq013

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Radiation exposure in children during the current era of pediatric cardiac intervention.

Authors:  Maiy Hamdy El Sayed; Alaa Mahmoud Roushdy; Hala El Farghaly; Ahmad El Sherbini
Journal:  Pediatr Cardiol       Date:  2011-08-03       Impact factor: 1.655

2.  How accurately can the peak skin dose in fluoroscopy be determined using indirect dose metrics?

Authors:  A Kyle Jones; Joe E Ensor; Alexander S Pasciak
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

3.  A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

Authors:  R Zotova; J Vassileva; J Hristova; M Pirinen; H Järvinen
Journal:  Eur Radiol       Date:  2012-02-19       Impact factor: 5.315

4.  Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention.

Authors:  Zhigeng Jin; Shengli Yang; Limin Jing; Huiliang Liu
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

5.  Measurement of skin dose from cone-beam computed tomography imaging.

Authors:  Sercan Akyalcin; Jeryl D English; Kenneth M Abramovitch; Xiujiang J Rong
Journal:  Head Face Med       Date:  2013-10-09       Impact factor: 2.151

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.