Literature DB >> 9534698

Estimation of effective dose in some digital angiographic and interventional procedures.

R Ruiz Cruces1, J García-Granados, F J Diaz Romero, J Hernández Armas.   

Abstract

In general, effective dose values for similar interventional vascular radiology (IVR) procedures are different. This is due to problems with the classification of radiological procedures, which make comparisons difficult. Patient size, examination technique and clinical condition as well as the skill of the medical radiologists also affect effective dose. Currently, there is a broad agreement on the classification of similar procedures so that effective dose estimates can be made from measurements of the dose area product (DAP). Thus, reference dose values may be established and comparative studies between different services and hospitals can be made. The objective of this study is to provide dose data for some digital angiographic and interventional procedures. Values of measured DAP for 143 patients for five types of procedures are presented. Procedures investigated were abdominal angiography, arteriography of lower limbs, biliary drainage, embolization of spermatic vein and nephrostomy. All the procedures were performed using digital equipment. Values of DAP and effective dose were 30 Gy cm2 and 6.2 mSv for arteriography of lower limbs and 150 Gy cm2 and 38.2 mSv for biliary drainage. In each one of these procedures, effective dose values per minute of fluoroscopy and per radiography film have been calculated. It is possible to use this information for the rapid estimation of effective dose.

Entities:  

Mesh:

Year:  1998        PMID: 9534698     DOI: 10.1259/bjr.71.841.9534698

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  9 in total

1.  Radiation dose and risk from fluoroscopically guided percutaneous transluminal angioplasty and stenting in the abdominal region.

Authors:  John Stratakis; John Damilakis; Dimitrios Tsetis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2007-03-27       Impact factor: 5.315

2.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

3.  Percutaneous nephrolithotripsy: C-arm CT with 3D virtual navigation in non-dilated renal collecting systems.

Authors:  Dechao Jiao; Zhanli Zhang; Zhanguo Sun; Yanli Wang; Xinwei Han
Journal:  Diagn Interv Radiol       Date:  2018 Jan-Feb       Impact factor: 2.630

4.  A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

Authors:  R Zotova; J Vassileva; J Hristova; M Pirinen; H Järvinen
Journal:  Eur Radiol       Date:  2012-02-19       Impact factor: 5.315

5.  Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

Authors:  R Ruiz-Cruces; E Vano; F Carrera-Magariño; F Moreno-Rodriguez; M M Soler-Cantos; M Canis-Lopez; J Hernández-Armas; F J Diaz-Romero; F Rosales-Espizua; J M Fernandez-Soto; R Sanchez-Casanueva; A Martin-Palanca; M Perez-Martinez; A Gil-Agudo; M A Zarca-Diaz; V Parra-Osorio; J J Muñoz Ruiz-Canela; T Moreno-Sanchez; A Lopez-Medina; C Moreno-Saiz; P Galan-Montenegro; J J Gallego-Beuter; M Gonzalez-de-Garay; J C Zapata-Jimenez; J M Pastor-Vega; S Cañete
Journal:  Eur Radiol       Date:  2016-07-06       Impact factor: 5.315

6.  Evaluation of radiation dose to patients undergoing interventional radiology procedures at Ramathibodi Hospital, Thailand.

Authors:  J Urairat; S Asavaphatiboon; S Singhara Na Ayuthaya; N Pongnapang
Journal:  Biomed Imaging Interv J       Date:  2011-07-01

7.  Dose evaluation for skin and organ in hepatocellular carcinoma during angiographic procedure.

Authors:  Daniela D'Alessio; Claudia Giliberti; Antonella Soriani; Livio Carpanese; Giuseppe Pizzi; Giulio Vallati; Lidia Strigari
Journal:  J Exp Clin Cancer Res       Date:  2013-10-25

8.  A survey of organ equivalent and effective doses from diagnostic radiology procedures.

Authors:  Ernest K Osei; Johnson Darko
Journal:  ISRN Radiol       Date:  2012-09-06

9.  Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm).

Authors:  Yang-Sub Lee; Hae-Kag Lee; Jae-Hwan Cho; Ham-Gyum Kim
Journal:  J Res Med Sci       Date:  2015-01       Impact factor: 1.852

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.