Literature DB >> 22156174

Ultra-low dose CT attenuation correction for PET/CT.

Ting Xia1, Adam M Alessio, Bruno De Man, Ravindra Manjeshwar, Evren Asma, Paul E Kinahan.   

Abstract

A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the n class="Chemical">currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging.

Entities:  

Mesh:

Year:  2011        PMID: 22156174      PMCID: PMC3353418          DOI: 10.1088/0031-9155/57/2/309

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  43 in total

Review 1.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

2.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

4.  Penalized-likelihood sinogram smoothing for low-dose CT.

Authors:  Patrick J La Rivière
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

5.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

6.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

7.  Attenuation correction for a combined 3D PET/CT scanner.

Authors:  P E Kinahan; D W Townsend; T Beyer; D Sashin
Journal:  Med Phys       Date:  1998-10       Impact factor: 4.071

8.  "Anatometabolic" tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity.

Authors:  R L Wahl; L E Quint; R D Cieslak; A M Aisen; R A Koeppe; C R Meyer
Journal:  J Nucl Med       Date:  1993-07       Impact factor: 10.057

9.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236

10.  Radiation dose to patients from radiopharmaceuticals. Addendum 3 to ICRP Publication 53. ICRP Publication 106. Approved by the Commission in October 2007.

Authors: 
Journal:  Ann ICRP       Date:  2008
View more
  32 in total

1.  Dual energy CT for attenuation correction with PET/CT.

Authors:  Ting Xia; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

2.  SPULTRA: Low-Dose CT Image Reconstruction With Joint Statistical and Learned Image Models.

Authors:  Siqi Ye; Saiprasad Ravishankar; Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2019-08-12       Impact factor: 10.048

3.  Generation of a Four-Class Attenuation Map for MRI-Based Attenuation Correction of PET Data in the Head Area Using a Novel Combination of STE/Dixon-MRI and FCM Clustering.

Authors:  Parisa Khateri; Hamidreza Saligheh Rad; Amir Homayoun Jafari; Anahita Fathi Kazerooni; Afshin Akbarzadeh; Mohsen Shojae Moghadam; Arvin Aryan; Pardis Ghafarian; Mohammad Reza Ay
Journal:  Mol Imaging Biol       Date:  2015-12       Impact factor: 3.488

4.  (18)F-NaF PET/CT: EANM procedure guidelines for bone imaging.

Authors:  M Beheshti; F M Mottaghy; F Paycha; F F F Behrendt; T Van den Wyngaert; I Fogelman; K Strobel; M Celli; S Fanti; F Giammarile; B Krause; W Langsteger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-07-23       Impact factor: 9.236

5.  Automatic registration of misaligned CT attenuation correction maps in Rb-82 PET/CT improves detection of angiographically significant coronary artery disease.

Authors:  Piotr J Slomka; Mariana Diaz-Zamudio; Damini Dey; Manish Motwani; Yafim Brodov; David Choi; Sean Hayes; Louise Thomson; John Friedman; Guido Germano; Daniel Berman
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

6.  Status of cardiovascular PET radiation exposure and strategies for reduction: An Information Statement from the Cardiovascular PET Task Force.

Authors:  James A Case; Robert A deKemp; Piotr J Slomka; Mark F Smith; Gary V Heller; Manuel D Cerqueira
Journal:  J Nucl Cardiol       Date:  2017-05-16       Impact factor: 5.952

7.  Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging.

Authors:  Marvin Grossmann; Andreas A Giannopoulos; Fabiola A Bechtiger; Michael Messerli; Moritz Schwyzer; Dominik C Benz; Ken Kudura; Catherine Gebhard; Christoph Gräni; Aju P Pazhenkottil; Philipp A Kaufmann; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2018-06-19       Impact factor: 5.952

8.  Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging.

Authors:  Matthew J Nyflot; Tzu-Cheng Lee; Adam M Alessio; Scott D Wollenweber; Charles W Stearns; Stephen R Bowen; Paul E Kinahan
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

9.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

Review 10.  Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging.

Authors:  Tzu C Lee; Adam M Alessio; Robert M Miyaoka; Paul E Kinahan
Journal:  Q J Nucl Med Mol Imaging       Date:  2015-11-17       Impact factor: 2.346

View more