Literature DB >> 9800714

Attenuation correction for a combined 3D PET/CT scanner.

P E Kinahan1, D W Townsend, T Beyer, D Sashin.   

Abstract

In this work we demonstrate the proof of principle of CT-based attenuation correction of 3D positron emission tomography (PET) data by using scans of bone and soft tissue equivalent phantoms and scans of humans. This method of attenuation correction is intended for use in a single scanner that combines volume-imaging (3D) PET with x-ray computed tomography (CT) for the purpose of providing accurately registered anatomical localization of structures seen in the PET image. The goal of this work is to determine if we can perform attenuation correction of the PET emission data using accurately aligned CT attenuation information. We discuss possible methods of calculating the PET attenuation map at 511 keV based on CT transmission information acquired from 40 keV through 140 keV. Data were acquired on separate CT and PET scanners and were aligned using standard image registration procedures. Results are presented on three of the attenuation calculation methods: segmentation, scaling, and our proposed hybrid segmentation/scaling method. The results are compared with those using the standard 3D PET attenuation correction method as a gold standard. We demonstrate the efficacy of our proposed hybrid method for converting the CT attenuation map from an effective CT photon energy of 70 keV to the PET photon energy of 511 keV. We conclude that using CT information is a feasible way to obtain attenuation correction factors for 3D PET.

Entities:  

Mesh:

Year:  1998        PMID: 9800714     DOI: 10.1118/1.598392

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  204 in total

1.  Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology.

Authors:  Thomas Beyer; Gerald Antoch; Todd Blodgett; Lutz F Freudenberg; Tim Akhurst; Stephan Mueller
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-02-12       Impact factor: 9.236

2.  Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation.

Authors:  Habib Zaidi; Marie-Louise Montandon; Daniel O Slosman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-22       Impact factor: 9.236

Review 3.  Impact of technology on the utilisation of positron emission tomography in lymphoma: current and future perspectives.

Authors:  D Visvikis; P J Ell
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-05-13       Impact factor: 9.236

4.  Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT.

Authors:  Medhat M Osman; Christian Cohade; Yuji Nakamoto; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-01-21       Impact factor: 9.236

5.  Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging.

Authors:  Philip Aschoff; Christian Plathow; Thomas Beyer; Matthias P Lichy; Gunter Erb; Mehmet Ö Öksüz; Claus D Claussen; Christina Pfannenberg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-11-29       Impact factor: 9.236

6.  Calcified Lymph Nodes Causing Clinically Relevant Attenuation Correction Artifacts on PET/CT Imaging.

Authors:  Amar Mehta; Ajeet Mehta; Charles Laymon; Todd M Blodgett
Journal:  J Radiol Case Rep       Date:  2010-02-01

7.  Evaluation of a 3D local multiresolution algorithm for the correction of partial volume effects in positron emission tomography.

Authors:  Adrien Le Pogam; Mathieu Hatt; Patrice Descourt; Nicolas Boussion; Charalampos Tsoumpas; Federico E Turkheimer; Caroline Prunier-Aesch; Jean-Louis Baulieu; Denis Guilloteau; Dimitris Visvikis
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

8.  Comparative assessment of energy-mapping approaches in CT-based attenuation correction for PET.

Authors:  Mohammad R Ay; Maryam Shirmohammad; Saeed Sarkar; Arman Rahmim; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2011-02       Impact factor: 3.488

Review 9.  Machine learning in quantitative PET: A review of attenuation correction and low-count image reconstruction methods.

Authors:  Tonghe Wang; Yang Lei; Yabo Fu; Walter J Curran; Tian Liu; Jonathon A Nye; Xiaofeng Yang
Journal:  Phys Med       Date:  2020-07-29       Impact factor: 2.685

10.  Comparison of the diagnostic accuracy of PET/MRI to PET/CT-acquired FDG brain exams for seizure focus detection: a prospective study.

Authors:  Michael J Paldino; Erica Yang; Jeremy Y Jones; Nadia Mahmood; Andrew Sher; Wei Zhang; Shireen Hayatghaibi; Ramkumar Krishnamurthy; Victor Seghers
Journal:  Pediatr Radiol       Date:  2017-05-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.