Literature DB >> 16013726

Penalized-likelihood sinogram smoothing for low-dose CT.

Patrick J La Rivière1.   

Abstract

We have developed a sinogram smoothing approach for low-dose computed tomography (CT) that seeks to estimate the line integrals needed for reconstruction from the noisy measurements by maximizing a penalized-likelihood objective function. The maximization is performed by an algorithm derived by use of the separable paraboloidal surrogates framework. The approach overcomes some of the computational limitations of a previously proposed spline-based penalized-likelihood sinogram smoothing approach, and it is found to yield better resolution-variance tradeoffs than this spline-based approach as well an existing adaptive filtering approach. Such sinogram smoothing approaches could be valuable when applied to the low-dose data acquired in CT screening exams, such as those being considered for lung-nodule detection.

Mesh:

Year:  2005        PMID: 16013726     DOI: 10.1118/1.1915015

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  46 in total

1.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

3.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

4.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

5.  Noise Reduction for Low-Dose Single-Slice Helical CT Sinograms.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2006-06       Impact factor: 1.679

6.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

7.  Multiscale penalized weighted least-squares sinogram restoration for low-dose X-ray computed tomography.

Authors:  Jing Wang; Zhengrong Liang; Hongbing Lu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

8.  Cardiac phase-correlated image reconstruction and advanced image processing in pulmonary CT imaging.

Authors:  Robert M Lapp; Marc Kachelriess; Dirk Ertel; Yiannis Kyriakou; Willi A Kalender
Journal:  Eur Radiol       Date:  2008-12-11       Impact factor: 5.315

9.  Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT.

Authors:  Qiaofeng Xu; Alex Sawatzky; Mark A Anastasio; Carsten O Schirra
Journal:  Phys Med Biol       Date:  2014-04-28       Impact factor: 3.609

10.  Dedicated breast computed tomography: volume image denoising via a partial-diffusion equation based technique.

Authors:  Jessie Q Xia; Joseph Y Lo; Kai Yang; Carey E Floyd; John M Boone
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.