Custom-fitted 16-channel bilateral breast coil for bidirectional parallel imaging.

Anderson N Nnewihe1, Thomas Grafendorfer, Bruce L Daniel, Paul Calderon, Marcus T Alley, Fraser Robb, Brian A Hargreaves.   

Abstract

A 16-channel receive-only, closely fitted array coil is described and tested in vivo for bilateral breast imaging at 3 T. The primary purpose of this coil is to provide high signal-to-noise ratio and parallel imaging acceleration in two directions for breast MRI. Circular coil elements (7.5-cm diameter) were placed on a closed "cup-shaped" platform, and nearest neighbor coils were decoupled through geometric overlap. Comparisons were made between the 16-channel custom coil and a commercially available 8-channel coil. SENSitivity Encoding (SENSE) parallel imaging noise amplification (g-factor) was evaluated in phantom scans. In healthy volunteers, we compared signal-to-noise ratio, parallel imaging in one and two directions, Autocalibrating Reconstruction for Cartesian sampling (ARC) g-factor, and high spatial resolution imaging. When compared with a commercially available 8-channel coil, the 16-channel custom coil shows 3.6× higher mean signal-to-noise ratio in the breast and higher quality accelerated images. In patients, the 16-channel custom coil has facilitated high-quality, high-resolution images with bidirectional acceleration of R = 6.3.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21287593      PMCID: PMC3128917          DOI: 10.1002/mrm.22771

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

2.  Image reconstruction in SNR units: a general method for SNR measurement.

Authors:  Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

Review 3.  Parallel MR imaging: a user's guide.

Authors:  James F Glockner; Houchun H Hu; David W Stanley; Lisa Angelos; Kevin King
Journal:  Radiographics       Date:  2005 Sep-Oct       Impact factor: 5.333

4.  Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy.

Authors:  Bernd J Wintersperger; Scott B Reeder; Konstantin Nikolaou; Olaf Dietrich; Armin Huber; Andreas Greiser; Titus Lanz; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2006-02       Impact factor: 4.813

5.  32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry.

Authors:  G C Wiggins; C Triantafyllou; A Potthast; A Reykowski; M Nittka; L L Wald
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

Review 6.  Parallel imaging in cardiovascular MRI: methods and applications.

Authors:  Thoralf Niendorf; Daniel K Sodickson
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

Review 7.  The current status of breast MR imaging. Part I. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice.

Authors:  Christiane Kuhl
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

8.  American Cancer Society guidelines for breast screening with MRI as an adjunct to mammography.

Authors:  Debbie Saslow; Carla Boetes; Wylie Burke; Steven Harms; Martin O Leach; Constance D Lehman; Elizabeth Morris; Etta Pisano; Mitchell Schnall; Stephen Sener; Robert A Smith; Ellen Warner; Martin Yaffe; Kimberly S Andrews; Christy A Russell
Journal:  CA Cancer J Clin       Date:  2007 Mar-Apr       Impact factor: 508.702

9.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

10.  Diagnostic accuracy of high-resolution MRI using a microscopy coil for patients with presumed DCIS following mammography screening.

Authors:  Jingzhi Zhu; Yasuyuki Kurihara; Yoshihide Kanemaki; Haruki Ogata; Mamoru Fukuda; Yasuo Nakajima; Ichiro Maeda
Journal:  J Magn Reson Imaging       Date:  2007-01       Impact factor: 4.813

View more
  10 in total

1.  Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

2.  Simultaneous bilateral-knee MR imaging.

Authors:  Feliks Kogan; Evan Levine; Akshay S Chaudhari; Uchechukwuka D Monu; Kevin Epperson; Edwin H G Oei; Garry E Gold; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2017-12-17       Impact factor: 4.668

3.  Radiofrequency coils for musculoskeletal magnetic resonance imaging.

Authors:  Kambiz A Asher; Neal K Bangerter; Ronald D Watkins; Garry E Gold
Journal:  Top Magn Reson Imaging       Date:  2010-10

4.  Flexible, 31-Channel breast coil for enhanced parallel imaging performance at 3T.

Authors:  Ileana Hancu; Eric Fiveland; Keith Park; Randy O Giaquinto; Kenneth Rohling; Florian Wiesinger
Journal:  Magn Reson Med       Date:  2015-03-13       Impact factor: 4.668

5.  High-frequency subband compressed sensing MRI using quadruplet sampling.

Authors:  Kyunghyun Sung; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2012-12-27       Impact factor: 4.668

6.  Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  Eur Radiol       Date:  2013-07-30       Impact factor: 5.315

7.  A semiflexible 64-channel receive-only phased array for pediatric body MRI at 3T.

Authors:  Tao Zhang; Thomas Grafendorfer; Joseph Y Cheng; Peigang Ning; Bob Rainey; Mark Giancola; Sarah Ortman; Fraser J Robb; Paul D Calderon; Brian A Hargreaves; Michael Lustig; Greig C Scott; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2015-09-29       Impact factor: 4.668

8.  A 16-channel receive, forced current excitation dual-transmit coil for breast imaging at 7T.

Authors:  Samantha By; Joseph V Rispoli; Sergey Cheshkov; Ivan Dimitrov; Jiaming Cui; Stephen Seiler; Sally Goudreau; Craig Malloy; Steven M Wright; Mary Preston McDougall
Journal:  PLoS One       Date:  2014-11-24       Impact factor: 3.240

Review 9.  Current and Emerging Magnetic Resonance-Based Techniques for Breast Cancer.

Authors:  Apekshya Chhetri; Xin Li; Joseph V Rispoli
Journal:  Front Med (Lausanne)       Date:  2020-05-12

10.  A 12-channel flexible receiver coil for accelerated tongue imaging.

Authors:  Luuk Voskuilen; Paul de Heer; Lisette van der Molen; Alfons J M Balm; Ferdinand van der Heijden; Gustav J Strijkers; Ludi E Smeele; Aart J Nederveen
Journal:  MAGMA       Date:  2020-01-16       Impact factor: 2.310

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.