Literature DB >> 21937611

Effective dose delivered by conventional radiology to Aosta Valley population between 2002 and 2009.

F Zenone1, S Aimonetto, P Catuzzo, A Peruzzo Cornetto, P Marchisio, M Natrella, A M Rosanò, T Meloni, M Pasquino, S Tofani.   

Abstract

OBJECTIVE: Medical diagnostic procedures can be considered the main man-made source of ionising radiation exposure for the population. Conventional radiography still represents the largest contribution to examination frequency. The present work evaluates procedure frequency and effective dose from the majority of conventional radiology examinations performed at the Radiological Department of Aosta Hospital from 2002 to 2009.
METHOD: Effective dose to the patient was evaluated by means of the software PCXMC. Data provided by the radiological information system allowed us to obtain collective effective and per caput dose.
RESULTS: The biggest contributors to per caput effective dose from conventional radiology are vertebral column, abdomen, chest, pelvis and (limited to females) breast. Vertebral column, pelvis and breast procedures show a significant dose increment in the period of the study. The mean effective dose per inhabitant from conventional radiology increased from 0.131 mSv in 2002 to 0.156 mSv in 2009. Combining these figures with those from our study of effective dose from CT (0.55 mSv in 2002 to 1.03 mSv in 2009), the total mean effective dose per inhabitant increased from 0.68 mSv to 1.19 mSv. The contribution of CT increased from 81% to 87% of the total. In contrast, conventional radiology accounts for 85% of the total number of procedures, but only 13% of the effective dose.
CONCLUSION: The study has demonstrated that conventional radiography still represents the biggest contributor to examination frequency in Aosta Valley in 2009. However, the frequency of the main procedures did not change significantly between 2002 and 2009.

Entities:  

Mesh:

Year:  2011        PMID: 21937611      PMCID: PMC3474076          DOI: 10.1259/bjr/19099861

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  15 in total

1.  Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008.

Authors:  P Catuzzo; S Aimonetto; F Zenone; G Fanelli; P Marchisio; T Meloni; M Pasquino; S Tofani
Journal:  Br J Radiol       Date:  2010-12       Impact factor: 3.039

2.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

3.  Population exposure to ionizing radiation from medical examinations in France.

Authors:  P Scanff; J Donadieu; P Pirard; B Aubert
Journal:  Br J Radiol       Date:  2008-03       Impact factor: 3.039

Review 4.  Effective doses in radiology and diagnostic nuclear medicine: a catalog.

Authors:  Fred A Mettler; Walter Huda; Terry T Yoshizumi; Mahadevappa Mahesh
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

5.  Medical exposure of the population from diagnostic use of ionizing radiation in luxembourg between 1994 and 2002.

Authors:  Ferid Shannoun; Hajo Zeeb; Carlo Back; Maria Blettner
Journal:  Health Phys       Date:  2006-08       Impact factor: 1.316

6.  Local diagnostic reference levels in standard X-ray examinations.

Authors:  Gaetano Compagnone; Laura Pagan; Carlo Bergamini
Journal:  Radiat Prot Dosimetry       Date:  2004-11-30       Impact factor: 0.972

7.  [Acquisition and assessment of patient exposure in diagnostic radiology and nuclear medicine].

Authors:  Dieter Regulla; Jürgen Griebel; Dietmar Nosske; Burkhard Bauer; Gunnar Brix
Journal:  Z Med Phys       Date:  2003       Impact factor: 4.820

8.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

9.  Patient dose and image quality in five standard x-ray examinations.

Authors:  R Havukainen; M Pirinen
Journal:  Med Phys       Date:  1993 May-Jun       Impact factor: 4.071

10.  Nation-wide survey on radiation doses in diagnostic and interventional radiology in Switzerland in 1998.

Authors:  A Aroua; B Burnand; I Decka; J P Vader; J F Valley
Journal:  Health Phys       Date:  2002-07       Impact factor: 1.316

View more
  8 in total

1.  European Guidelines for AP/PA chest X-rays: routinely satisfiable in a paediatric radiology division?

Authors:  Sebastian Tschauner; Robert Marterer; Michael Gübitz; Peter I Kalmar; Emina Talakic; Sabine Weissensteiner; Erich Sorantin
Journal:  Eur Radiol       Date:  2015-05-24       Impact factor: 5.315

2.  Assessment of PCXMC for patients with different body size in chest and abdominal x ray examinations: a Monte Carlo simulation study.

Authors:  David Borrego; Erin M Lowe; Cari M Kitahara; Choonsik Lee
Journal:  Phys Med Biol       Date:  2018-03-21       Impact factor: 3.609

3.  The contribution of interventional cardiology procedures to the population radiation dose in a 'health-care level I' representative region.

Authors:  Andrea Peruzzo Cornetto; Stefania Aimonetto; Francesco Pisano; Marcello Giudice; Marco Sicuro; Teodoro Meloni; Santi Tofani
Journal:  Radiat Prot Dosimetry       Date:  2015-05-25       Impact factor: 0.972

4.  Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, Iran.

Authors:  Akbar Aliasgharzadeh; Ehsan Mihandoost; Mahboubeh Masoumbeigi; Morteza Salimian; Mehran Mohseni
Journal:  Glob J Health Sci       Date:  2015-02-24

5.  Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction.

Authors:  Go Shirota; Eriko Maeda; Yoko Namiki; Razibul Bari; Kenji Ino; Rumiko Torigoe; Osamu Abe
Journal:  Pediatr Radiol       Date:  2017-06-30

6.  Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector.

Authors:  S Notohamiprodjo; K M Roeper; K M Treitl; B Hoberg; F Wanninger; L Verstreepen; F G Mueck; D Maxien; F Fischer; O Peschel; S Wirth
Journal:  Sci Rep       Date:  2021-04-08       Impact factor: 4.379

7.  Advances in multiscale image processing and its effects on image quality in skeletal radiography.

Authors:  Susan Notohamiprodjo; K M Roeper; F G Mueck; D Maxien; F Wanninger; B Hoberg; L Verstreepen; K M Treitl; F Fischer; O Peschel; S Wirth
Journal:  Sci Rep       Date:  2022-03-18       Impact factor: 4.379

8.  Patient organ and effective dose estimation in CT: comparison of four software applications.

Authors:  Cristina De Mattia; Federica Campanaro; Federica Rottoli; Paola Enrica Colombo; Andrea Pola; Angelo Vanzulli; Alberto Torresin
Journal:  Eur Radiol Exp       Date:  2020-02-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.