Literature DB >> 26002133

European Guidelines for AP/PA chest X-rays: routinely satisfiable in a paediatric radiology division?

Sebastian Tschauner1, Robert Marterer2, Michael Gübitz2, Peter I Kalmar3, Emina Talakic4, Sabine Weissensteiner2, Erich Sorantin2.   

Abstract

OBJECTIVES: Accurate collimation helps to reduce unnecessary irradiation and improves radiographic image quality, which is especially important in the radiosensitive paediatric population. For AP/PA chest radiographs in children, a minimal field size (MinFS) from "just above the lung apices" to "T12/L1" with age-dependent tolerance is suggested by the 1996 European Commission (EC) guidelines, which were examined qualitatively and quantitatively at a paediatric radiology division.
METHODS: Five hundred ninety-eight unprocessed chest X-rays (45% boys, 55% girls; mean age 3.9 years, range 0-18 years) were analysed with a self-developed tool. Qualitative standards were assessed based on the EC guidelines, as well as the overexposed field size and needlessly irradiated tissue compared to the MinFS.
RESULTS: While qualitative guideline recommendations were satisfied, mean overexposure of +45.1 ± 18.9% (range +10.2% to +107.9%) and tissue overexposure of +33.3 ± 13.3% were found. Only 4% (26/598) of the examined X-rays completely fulfilled the EC guidelines.
CONCLUSIONS: This study presents a new chest radiography quality control tool which allows assessment of field sizes, distances, overexposures and quality parameters based on the EC guidelines. Utilising this tool, we detected inadequate field sizes, inspiration depths, and patient positioning. Furthermore, some debatable EC guideline aspects were revealed. KEY POINTS: • European Guidelines on X-ray quality recommend exposed field sizes for common examinations. • The major failing in paediatric radiographic imaging techniques is inappropriate field size. • Optimal handling of radiographic units can reduce radiation exposure to paediatric patients. • Constant quality control helps ensure optimal chest radiographic image acquisition in children.

Entities:  

Keywords:  Paediatrics; Radiation protection; Radiographic image enhancement; Standards; Thoracic radiography

Mesh:

Year:  2015        PMID: 26002133     DOI: 10.1007/s00330-015-3836-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  34 in total

1.  Irish X-ray departments demonstrate varying levels of adherence to European guidelines on good radiographic technique.

Authors:  P C Brennan; D Johnston
Journal:  Br J Radiol       Date:  2002-03       Impact factor: 3.039

2.  ACR white paper on radiation dose in medicine: three years later.

Authors:  E Stephen Amis; Priscilla F Butler
Journal:  J Am Coll Radiol       Date:  2010-11       Impact factor: 5.532

3.  The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams--a white paper conference.

Authors:  Charles E Willis; Thomas L Slovis
Journal:  AJR Am J Roentgenol       Date:  2005-02       Impact factor: 3.959

4.  Best practices in digital radiography.

Authors:  Tracy L Herrmann; Terri L Fauber; Julie Gill; Colleen Hoffman; Denise K Orth; Paulette A Peterson; Randy R Prouty; Andrew P Woodward; Teresa G Odle
Journal:  Radiol Technol       Date:  2012 Sep-Oct

5.  [Quality of ambulatory thoracic radiography in the child--a pilot study].

Authors:  D Engelmann; T Dütting; R Wunsch; J Tröger
Journal:  Radiologe       Date:  2001-05       Impact factor: 0.635

6.  Potential for optimisation of paediatric chest X-ray examination.

Authors:  D Kostova-Lefterova; D Taseva; K Ingilizova; J Hristova-Popova; J Vassileva
Journal:  Radiat Prot Dosimetry       Date:  2011-08-08       Impact factor: 0.972

7.  X-ray field size and patient dosimetry.

Authors:  Terri L Fauber; Melanie C Dempsey
Journal:  Radiol Technol       Date:  2013 Nov-Dec

Review 8.  Managing patient stress in pediatric radiology.

Authors:  Melody Alexander
Journal:  Radiol Technol       Date:  2012 Jul-Aug

9.  Use of World Health Organization and CDC growth charts for children aged 0-59 months in the United States.

Authors:  Laurence M Grummer-Strawn; Chris Reinold; Nancy F Krebs
Journal:  MMWR Recomm Rep       Date:  2010-09-10

10.  Diagnostic reference levels in pediatric radiology in Austria.

Authors:  Jochen Billinger; Robert Nowotny; Peter Homolka
Journal:  Eur Radiol       Date:  2010-01-22       Impact factor: 5.315

View more
  2 in total

1.  Organ doses in preterm and full-term neonates and infants - a retrospective study on 1,064 chest radiographs.

Authors:  Birgit Kammer; Karl O Schneider; Evi Dell'Agnolo; Michael C Seidenbusch
Journal:  Pediatr Radiol       Date:  2022-03-18

2.  Evaluating the principles of radiation protection in diagnostic radiologic examinations: collimation, exposure factors and use of protective equipment for the patients and their companions.

Authors:  Zahra Farzanegan; Marziyeh Tahmasbi; Mohsen Cheki; Fatameh Yousefvand; Mohammad Rajabi
Journal:  J Med Radiat Sci       Date:  2020-03-09
  2 in total