Limitations of using micro-computed tomography to predict bone-implant contact and mechanical fixation.

S Liu1, J Broucek, A S Virdi, D R Sumner.   

Abstract

Fixation of metallic implants to bone through osseointegration is important in orthopaedics and dentistry. Model systems for studying this phenomenon would benefit from a non-destructive imaging modality so that mechanical and morphological endpoints can more readily be examined in the same specimens. The purpose of this study was to assess the utility of an automated microcomputed tomography (μCT) program for predicting bone-implant contact (BIC) and mechanical fixation strength in a rat model. Femurs in which 1.5-mm-diameter titanium implants had been in place for 4 weeks were either embedded in polymethylmethacrylate (PMMA) for preparation of 1-mm-thick cross-sectional slabs (16 femurs: 32 slabs) or were used for mechanical implant pull-out testing (n= 18 femurs). All samples were scanned by μCT at 70 kVp with 16 μm voxels and assessed by the manufacturer's software for assessing 'osseointegration volume per total volume' (OV/TV). OV/TV measures bone volume per total volume (BV/TV) in a 3-voxel-thick ring that by default excludes the 3 voxels immediately adjacent to the implant to avoid metal-induced artefacts. The plastic-embedded samples were also analysed by backscatter scanning electron microscopy (bSEM) to provide a direct comparison of OV/TV with a well-accepted technique for BIC. In μCT images in which the implant was directly embedded within PMMA, there was a zone of elevated attenuation (>50% of the attenuation value used to segment bone from marrow) which extended 48 μm away from the implant surface. Comparison of the bSEM and μCT images showed high correlations for BV/TV measurements in areas not affected by metal-induced artefacts. In addition for bSEM images, we found that there were high correlations between peri-implant BV/TV within 12 μm of the implant surface and BIC (correlation coefficients ≥0.8, p < 0.05). OV/TV as measured on μCT images was not significantly correlated with BIC as measured on the corresponding bSEM images. However, OV/TV was significantly, but weakly, correlated with implant pull-out strength (r= 0.401, p= 0.049) and energy to failure (r= 0.435, p= 0.035). Thus, the need for the 48-μm-thick exclusion zone in the OV/TV program to avoid metal-induced artefacts with the scanner used in this study means that it is not possible to make bone measurements sufficiently close to the implant surface to obtain an accurate assessment of BIC. Current generation laboratory-based μCT scanners typically have voxel sizes of 6-8 μm or larger which will still not overcome this limitation. Thus, peri-implant bone measurements at these resolutions should only be used as a guide to predict implant fixation and should not be over-interpreted as a measurement of BIC. Newer generation laboratory-based μCT scanners have several improvements including better spatial resolution and X-ray sources and appear to have less severe metal-induced artefacts, but will need appropriate validation as they become available to researchers. Regardless of the μCT scanner being used, we recommend that detailed validation studies be performed for any study using metal implants because variation in the composition and geometry of the particular implants used may lead to different artefact patterns.
© 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21919905      PMCID: PMC3767165          DOI: 10.1111/j.1365-2818.2011.03541.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  23 in total

1.  Morphometric and mechanical evaluation of titanium implant integration: comparison of five surface structures.

Authors:  M Svehla; P Morberg; B Zicat; W Bruce; D Sonnabend; W R Walsh
Journal:  J Biomed Mater Res       Date:  2000-07

2.  The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography.

Authors:  Corinne Schouten; Gert J Meijer; Jeroen J J P van den Beucken; Paul H M Spauwen; John A Jansen
Journal:  Biomaterials       Date:  2009-06-04       Impact factor: 12.479

3.  Histology of porous-coated acetabular components. 25 cementless cups retrieved after arthroplasty.

Authors:  D R Sumner; M Jasty; J J Jacobs; R M Urban; C R Bragdon; W H Harris; J O Galante
Journal:  Acta Orthop Scand       Date:  1993-12

Review 4.  Osseointegration and its experimental background.

Authors:  P I Brånemark
Journal:  J Prosthet Dent       Date:  1983-09       Impact factor: 3.426

5.  Osseointegration of Ti6Al4V alloy implants coated with titanium nitride by a new method.

Authors:  G Sovak; A Weiss; I Gotman
Journal:  J Bone Joint Surg Br       Date:  2000-03

6.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

7.  A low-temperature biomimetic calcium phosphate surface enhances early implant fixation in a rat model.

Authors:  S Kuroda; A S Virdi; P Li; K E Healy; D R Sumner
Journal:  J Biomed Mater Res A       Date:  2004-07-01       Impact factor: 4.396

8.  Endosseous implant anchorage is critically dependent on mechanostructural determinants of peri-implant bone trabeculae.

Authors:  Yankel Gabet; David Kohavi; Romain Voide; Thomas L Mueller; Ralph Müller; Itai Bab
Journal:  J Bone Miner Res       Date:  2010-03       Impact factor: 6.741

9.  Quantitative microcomputed tomography analysis of mineralization within three-dimensional scaffolds in vitro.

Authors:  Sarah Cartmell; Kimberly Huynh; Angela Lin; Srinidhi Nagaraja; Robert Guldberg
Journal:  J Biomed Mater Res A       Date:  2004-04-01       Impact factor: 4.396

10.  Hydroxyapatite particles maintain peri-implant bone mantle during osseointegration in osteoporotic bone.

Authors:  Andrea E Tami; Melanie M Leitner; Michelle G Baucke; Thomas L Mueller; G Harry van Lenthe; Ralph Müller; Keita Ito
Journal:  Bone       Date:  2009-08-11       Impact factor: 4.398

View more
  17 in total

1.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

2.  Comparative assessment of the interfacial soft and hard tissues investing implants and natural teeth in the macaque mandible.

Authors:  Chong Huat Siar; Chooi Gait Toh; Georgios E Romanos; Kok Han Ng
Journal:  Clin Oral Investig       Date:  2014-11-21       Impact factor: 3.573

Review 3.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

4.  Osseointegration of Coarse and Fine Textured Implants Manufactured by Electron Beam Melting and Direct Metal Laser Sintering.

Authors:  David S Ruppert; Ola L A Harrysson; Denis J Marcellin-Little; Sam Abumoussa; Laurence E Dahners; Paul S Weinhold
Journal:  3D Print Addit Manuf       Date:  2017-06-01       Impact factor: 5.449

5.  Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

Authors:  Matthew J Meagher; Rachna N Parwani; Amarjit S Virdi; Dale R Sumner
Journal:  J Orthop Res       Date:  2017-10-04       Impact factor: 3.494

6.  Implant surface alters compartmental-specific contributions to fixation strength in rats.

Authors:  Frank C Ko; Matthew J Meagher; Maleeha Mashiatulla; Ryan D Ross; Amarjit S Virdi; Dale R Sumner
Journal:  J Orthop Res       Date:  2019-12-25       Impact factor: 3.494

7.  Locally delivered minocycline microspheres do not impair osseointegration of titanium implants in a rat femur model.

Authors:  Joshua A Shapiro; Samuel AbuMoussa; Christopher P Lindsay; Gabriel B Mason; Laurence E Dahners; Paul S Weinhold
Journal:  J Orthop       Date:  2019-12-12

8.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

9.  Osseointegration of a novel 3D porous Ti-6Al-4V implant material - Histomorphometric analysis in rabbits.

Authors:  Stephan Frosch; Gottfried Buchhorn; Sebastian Krohn; Wolfgang Lehmann; Karl-Heinz Frosch; László Füzesi; Alice Frosch
Journal:  Histol Histopathol       Date:  2021-05-11       Impact factor: 2.303

10.  Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

Authors:  Sung-Won Kang; Woo-Jin Lee; Soon-Chul Choi; Sam-Sun Lee; Min-Suk Heo; Kyung-Hoe Huh; Tae-Il Kim; Won-Jin Yi
Journal:  Imaging Sci Dent       Date:  2015-03-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.