Literature DB >> 31821588

Implant surface alters compartmental-specific contributions to fixation strength in rats.

Frank C Ko1, Matthew J Meagher1, Maleeha Mashiatulla1,2, Ryan D Ross1, Amarjit S Virdi1, Dale R Sumner1.   

Abstract

Mechanical fixation of the implant to host bone is an important contributor to orthopedic implant survivorship. The relative importance of bone-implant contact, trabecular bone architecture, and cortical bone geometry to implant fixation strength has never been directly tested, especially in the settings of differential implant surface properties. Thus, using a rat model where titanium rods were placed into the intramedullary canal of the distal femur, we determined the relative contribution of bone-implant contact and peri-implant bone architecture to the fixation strength in implants with different surface roughness: highly polished and smooth (as-received) and dual acid-etched (DAE) implants. Using a training set that maximized variance in implant fixation strength, we initially examined correlation between implant fixation strength and outcome parameters from microcomputed tomography and found that osseointegration volume per total volume (OV/TV), trabecular bone volume per total volume (BV/TV), and cortical thickness (Ct.Th) were the single best compartment-specific predictors of fixation strength. We defined separate regression models to predict implant fixation strength for as-received and DAE implants. When the training set models were applied to independent validation sets, we found strong correlations between predicted and experimentally measured implant fixation strength, with r2  = .843 in as received and r2  = .825 in DAE implants. Interestingly, for as-received implants, OV/TV explained more of the total variance in implant fixation strength than the other variables, whereas in DAE implants, Ct.Th had the most explanatory power, suggesting that surface topography of implants affects which bone compartment is most important in providing implant fixation strength.
© 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  bone-implant contact; implant fixation strength; microCT; osseointegration

Mesh:

Year:  2019        PMID: 31821588      PMCID: PMC7225079          DOI: 10.1002/jor.24561

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  23 in total

1.  The Swedish Total Hip Replacement Register.

Authors:  Henrik Malchau; Peter Herberts; Thomas Eisler; Göran Garellick; Peter Söderman
Journal:  J Bone Joint Surg Am       Date:  2002       Impact factor: 5.284

2.  Peptide-modified p(AAm-co-EG/AAc) IPNs grafted to bulk titanium modulate osteoblast behavior in vitro.

Authors:  Thomas A Barber; Stephen L Golledge; David G Castner; Kevin E Healy
Journal:  J Biomed Mater Res A       Date:  2003-01-01       Impact factor: 4.396

3.  The effect of porosity and mineral content on the Young's modulus of elasticity of compact bone.

Authors:  J D Currey
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

4.  Biomechanical analysis of the effects of implant diameter and bone quality in short implants placed in the atrophic posterior maxilla.

Authors:  Shih-Hao Chang; Chun-Li Lin; Shue-Sang Hsue; Yang-Sung Lin; Shiang-Rung Huang
Journal:  Med Eng Phys       Date:  2011-07-31       Impact factor: 2.242

Review 5.  Multifunctional coatings to simultaneously promote osseointegration and prevent infection of orthopaedic implants.

Authors:  Jordan Raphel; Mark Holodniy; Stuart B Goodman; Sarah C Heilshorn
Journal:  Biomaterials       Date:  2016-01-18       Impact factor: 12.479

6.  Incidence and short-term outcomes of primary and revision hip replacement in the United States.

Authors:  Chunliu Zhan; Ronald Kaczmarek; Nilsa Loyo-Berrios; Judith Sangl; Roselie A Bright
Journal:  J Bone Joint Surg Am       Date:  2007-03       Impact factor: 5.284

7.  Sclerostin antibody treatment improves implant fixation in a model of severe osteoporosis.

Authors:  Amarjit S Virdi; John Irish; Kotaro Sena; Min Liu; Hua Zhu Ke; Margaret A McNulty; Dale R Sumner
Journal:  J Bone Joint Surg Am       Date:  2015-01-21       Impact factor: 5.284

8.  Trabecular bone gradient in rat long bone metaphyses: mathematical modeling and application to morphometric measurements and correction of implant positioning.

Authors:  Yankel Gabet; David Kohavi; Thomas Kohler; Mario Baras; Ralph Müller; Itai Bab
Journal:  J Bone Miner Res       Date:  2008-01       Impact factor: 6.741

9.  A low-temperature biomimetic calcium phosphate surface enhances early implant fixation in a rat model.

Authors:  S Kuroda; A S Virdi; P Li; K E Healy; D R Sumner
Journal:  J Biomed Mater Res A       Date:  2004-07-01       Impact factor: 4.396

10.  Controlled laser texturing of titanium results in reliable osteointegration.

Authors:  Melanie J Coathup; Gordon W Blunn; Nazanin Mirhosseini; Karen Erskine; Zhu Liu; David R Garrod; Lin Li
Journal:  J Orthop Res       Date:  2016-06-28       Impact factor: 3.494

View more
  2 in total

1.  Activation of canonical Wnt signaling accelerates intramembranous bone regeneration in male mice.

Authors:  Frank C Ko; Meghan M Moran; Ryan D Ross; D Rick Sumner
Journal:  J Orthop Res       Date:  2021-11-22       Impact factor: 3.102

2.  The relative contribution of bone microarchitecture and matrix composition to implant fixation strength in rats.

Authors:  Kyle D Anderson; Frank C Ko; Spencer Fullam; Amarjit S Virdi; Markus A Wimmer; Dale R Sumner; Ryan D Ross
Journal:  J Orthop Res       Date:  2021-06-06       Impact factor: 3.494

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.