Literature DB >> 30191161

Osseointegration of Coarse and Fine Textured Implants Manufactured by Electron Beam Melting and Direct Metal Laser Sintering.

David S Ruppert1, Ola L A Harrysson1,2, Denis J Marcellin-Little1,2,3, Sam Abumoussa4, Laurence E Dahners4, Paul S Weinhold1,4.   

Abstract

Osseointegrated implants transfer loads from native bone to a synthetic joint and can also function transdermally to provide a stable connection between the skeleton and the prostheses, eliminating many problems associated with socket prostheses. Additive manufacturing provides a cost-effective means to create patient-specific implants and allows for customized textures for integration with bone and other tissues. Our objective was to compare the osseointegration strength of two primary additive manufacturing methods of producing textured implants: electron beam melting (EBM) (mean Ra = 23 μm) and direct metal laser sintering (DMLS) (mean Ra = 10 μm). Due to spatial resolution, DMLS can produce surfaces with a roughness comparable to EBM. Two cohorts of Sprague-Dawley rats received bilateral, titanium implants in their distal femurs and were followed for 4 weeks. The first-cohort animals received EBM implants transcortically in one femur and a DMLS implant in the contralateral femur. The second cohort received DMLS implants (either fine textured or coarse textured to mimic EBM) in the intramedullary canal of each femur. Osseointegration was evaluated through mechanical testing and micro-computed tomography (bone volume fraction [BV/TV] and bone-implant contact [BIC]). The fixation strength of coarse textured implants provided superior interlocking relative to fine textured implants without affecting BV/TV or BIC in both cohorts. Coarse EBM implants in a transcortical model demonstrated an 85% increase in removal torque relative to the fine DMLS textured implants. The thrust load in the intramedullary model saw a 35% increase from fine to coarse DMLS implants.

Entities:  

Keywords:  additive manufactured implants; bone-implant interface; direct metal laser sintering; electron beam melting; osseointegration of transcutaneous prostheses

Year:  2017        PMID: 30191161      PMCID: PMC6114714          DOI: 10.1089/3dp.2017.0008

Source DB:  PubMed          Journal:  3D Print Addit Manuf        ISSN: 2329-7662            Impact factor:   5.449


  14 in total

1.  Surface modification of titanium by etching in concentrated sulfuric acid.

Authors:  Seiji Ban; Yukari Iwaya; Hiroshi Kono; Hideo Sato
Journal:  Dent Mater       Date:  2005-12-20       Impact factor: 5.304

2.  Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide.

Authors:  A Wennerberg; T Albrektsson; B Andersson
Journal:  Int J Oral Maxillofac Implants       Date:  1996 Jan-Feb       Impact factor: 2.804

3.  Rat tibial osteotomy model providing a range of normal to impaired healing.

Authors:  Joan D Miles; Paul Weinhold; Olubusola Brimmo; Laurence Dahners
Journal:  J Orthop Res       Date:  2011-01       Impact factor: 3.494

4.  Bone ingrowth potential of electron beam and selective laser melting produced trabecular-like implant surfaces with and without a biomimetic coating.

Authors:  J E Biemond; G Hannink; N Verdonschot; P Buma
Journal:  J Mater Sci Mater Med       Date:  2012-12-21       Impact factor: 3.896

5.  Low-magnitude high-frequency loading via whole body vibration enhances bone-implant osseointegration in ovariectomized rats.

Authors:  BaiLing Chen; YiQiang Li; DengHui Xie; XiaoXi Yang
Journal:  J Orthop Res       Date:  2011-11-04       Impact factor: 3.494

6.  A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies.

Authors:  A Wennerberg; T Albrektsson; B Andersson; J J Krol
Journal:  Clin Oral Implants Res       Date:  1995-03       Impact factor: 5.977

7.  Limitations of using micro-computed tomography to predict bone-implant contact and mechanical fixation.

Authors:  S Liu; J Broucek; A S Virdi; D R Sumner
Journal:  J Microsc       Date:  2011-09-15       Impact factor: 1.758

8.  Prevalence of Total Hip and Knee Replacement in the United States.

Authors:  Hilal Maradit Kremers; Dirk R Larson; Cynthia S Crowson; Walter K Kremers; Raynard E Washington; Claudia A Steiner; William A Jiranek; Daniel J Berry
Journal:  J Bone Joint Surg Am       Date:  2015-09-02       Impact factor: 5.284

9.  A Comparison of Biocompatibility of a Titanium Alloy Fabricated by Electron Beam Melting and Selective Laser Melting.

Authors:  Hong Wang; Bingjing Zhao; Changkui Liu; Chao Wang; Xinying Tan; Min Hu
Journal:  PLoS One       Date:  2016-07-08       Impact factor: 3.240

Review 10.  Biocompatibility of Advanced Manufactured Titanium Implants-A Review.

Authors:  Alfred T Sidambe
Journal:  Materials (Basel)       Date:  2014-12-19       Impact factor: 3.623

View more
  2 in total

1.  Locally delivered minocycline microspheres do not impair osseointegration of titanium implants in a rat femur model.

Authors:  Joshua A Shapiro; Samuel AbuMoussa; Christopher P Lindsay; Gabriel B Mason; Laurence E Dahners; Paul S Weinhold
Journal:  J Orthop       Date:  2019-12-12

2.  Osteogenic benefits of low-intensity pulsed ultrasound and vibration in a rodent osseointegration model.

Authors:  David S Ruppert; Ola LA Harrysson; Denis J Marcellin-Little; Seth Bollenbecker; Paul S Weinhold
Journal:  J Musculoskelet Neuronal Interact       Date:  2019-06-01       Impact factor: 2.041

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.