Literature DB >> 21602707

24-hour intraocular pressure fluctuation monitoring using an ocular telemetry Sensor: tolerability and functionality in healthy subjects.

Stefan De Smedt1, André Mermoud, Corinne Schnyder.   

Abstract

PURPOSE: To evaluate the tolerability, comfort, and reliability of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans. PATIENTS AND METHODS: In this uncontrolled open trial involving 10 healthy volunteers, an 8.7-mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best-corrected visual acuity and position, surface wetting ability, and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12, and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal, a full eye examination was repeated and the recorded signal analyzed.
RESULTS: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best-corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but 1 participant, we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.
CONCLUSIONS: This 24-hour trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision, and interpretation of the telemetric signal.

Entities:  

Mesh:

Year:  2012        PMID: 21602707     DOI: 10.1097/IJG.0b013e31821dac43

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  23 in total

1.  Reply to: 'TLP: a premature concept'.

Authors:  I Januleviciene; L Siaudvytyte; A Daveckaite; A Ragauskas; B Siesky; A Harris
Journal:  Eye (Lond)       Date:  2015-11-13       Impact factor: 3.775

2.  Intraocular pressure increases after complex simulated surgical procedures in residents: an experimental study.

Authors:  Jesús Vera; Carolina Diaz-Piedra; Raimundo Jiménez; Jose M Sanchez-Carrion; Leandro L Di Stasi
Journal:  Surg Endosc       Date:  2018-07-02       Impact factor: 4.584

3.  Improvement of fluctuations of intraocular pressure after cataract surgery in primary angle closure glaucoma patients.

Authors:  Naoki Tojo; Mitsuya Otsuka; Akio Miyakoshi; Kazuya Fujita; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-27       Impact factor: 3.117

4.  The acute effect of strength exercises at different intensities on intraocular pressure.

Authors:  Jesús Vera; Amador García-Ramos; Raimundo Jiménez; David Cárdenas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-07-12       Impact factor: 3.117

5.  Transient changes in refractive error and corneal tomography after 24-h continuous monitoring of intraocular pressure patterns with a contact lens sensor.

Authors:  Atsuya Miki; Miho Kumoi; Naoyuki Maeda; Shizuka Koh; Kenji Matsushita; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2020-02-13       Impact factor: 2.447

6.  Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma.

Authors:  Kaweh Mansouri; Felipe A Medeiros; Ali Tafreshi; Robert N Weinreb
Journal:  Arch Ophthalmol       Date:  2012-12

7.  Circadian rhythm of intraocular pressure in the adult rat.

Authors:  Diana C Lozano; Andrew T E Hartwick; Michael D Twa
Journal:  Chronobiol Int       Date:  2015-03-23       Impact factor: 2.877

Review 8.  An overview of home tonometry and telemetry for intraocular pressure monitoring in humans.

Authors:  Edward Yung; Valerie Trubnik; L Jay Katz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-29       Impact factor: 3.117

9.  Nocturnal Variability of Intraocular Pressure Monitored With Contact Lens Sensor Is Associated With Visual Field Loss in Glaucoma.

Authors:  Zhiyong Yang; Kaweh Mansouri; Sasan Moghimi; Robert N Weinreb
Journal:  J Glaucoma       Date:  2021-03-01       Impact factor: 2.290

10.  Efficacy of a contact lens sensor for monitoring 24-h intraocular pressure related patterns.

Authors:  Kaweh Mansouri; Robert N Weinreb; John H K Liu
Journal:  PLoS One       Date:  2015-05-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.