Literature DB >> 24862301

Improvement of fluctuations of intraocular pressure after cataract surgery in primary angle closure glaucoma patients.

Naoki Tojo1, Mitsuya Otsuka, Akio Miyakoshi, Kazuya Fujita, Atsushi Hayashi.   

Abstract

BACKGROUND: Cataract surgery has been shown to reduce intraocular pressure (IOP) in eyes with primary angle closure glaucoma (PACG). In this study, we examined IOP fluctuations and circadian IOP patterns before and after cataract surgery in PACG patients using the contact lens sensor (CLS) Triggerfish.
METHODS: This was a prospective open-label study. Ten consecutive patients with PACG were included. The patients underwent phacoemulsification and intraocular lens implantation (PEA+IOL) surgery. In each eye, IOP fluctuations over 24 h were measured with the CLS before and at three months after the surgery. Changes in corneal curvatures and anatomic parameters of the anterior chamber were measured by anterior segment optical coherence tomography (AS-OCT).
RESULTS: The mean IOP was significantly reduced from 14.7 ± 1.5 mmHg to 11.2 ± 2.2 mmHg at three months after the surgery in PACG patients (P = 0.002). Although the mean range of 24-h IOP fluctuations was not significantly changed after the surgery (P = 0.49), the mean range of IOP fluctuations during the nocturnal period was significantly decreased from 246 ± 61 mVeq to 179 ± 64 mVeq after the surgery (P = 0.02). After the surgery, seven eyes of the ten (70%) showed the same circadian IOP patterns. AS-OCT showed significant improvements in the anatomic parameters of the anterior chamber after the surgery.
CONCLUSIONS: Cataract surgery decreased IOP fluctuations during the nocturnal period in PACG patients. These effects might partly prevent the progression of PACG.

Entities:  

Mesh:

Year:  2014        PMID: 24862301     DOI: 10.1007/s00417-014-2666-7

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  21 in total

1.  Diurnal curve after phacoemulsification in patients with pseudoexfoliation syndrome and cataract.

Authors:  Aparna Rao
Journal:  Semin Ophthalmol       Date:  2012 Jan-Mar       Impact factor: 1.975

2.  Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes.

Authors:  Matteo Leonardi; Elie M Pitchon; Arnaud Bertsch; Philippe Renaud; André Mermoud
Journal:  Acta Ophthalmol       Date:  2008-11-12       Impact factor: 3.761

3.  Effects of phacoemulsification and intraocular lens implantation on intraocular pressure in primary angle closure glaucoma (PACG) patients.

Authors:  Nusara Yudhasompop; Boonchai Wangsupadilok
Journal:  J Med Assoc Thai       Date:  2012-04

4.  24-hour intraocular pressure fluctuation monitoring using an ocular telemetry Sensor: tolerability and functionality in healthy subjects.

Authors:  Stefan De Smedt; André Mermoud; Corinne Schnyder
Journal:  J Glaucoma       Date:  2012 Oct-Nov       Impact factor: 2.503

5.  24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor.

Authors:  Benjamin Mottet; Florent Aptel; Jean-Paul Romanet; Ralitsa Hubanova; Jean-Louis Pépin; Christophe Chiquet
Journal:  JAMA Ophthalmol       Date:  2013-12       Impact factor: 7.389

6.  Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma.

Authors:  S Asrani; R Zeimer; J Wilensky; D Gieser; S Vitale; K Lindenmuth
Journal:  J Glaucoma       Date:  2000-04       Impact factor: 2.503

7.  First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens.

Authors:  Matteo Leonardi; Peter Leuenberger; Daniel Bertrand; Arnaud Bertsch; Philippe Renaud
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-09       Impact factor: 4.799

8.  The number of people with glaucoma worldwide in 2010 and 2020.

Authors:  H A Quigley; A T Broman
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

9.  Diurnal intraocular pressure fluctuation and associated risk factors in eyes with angle closure.

Authors:  Mani Baskaran; Rajesh S Kumar; Chitra V Govindasamy; Hla Myint Htoon; Ching-Yee Wong; Shamira A Perera; Tina T L Wong; Tin Aung
Journal:  Ophthalmology       Date:  2009-10-22       Impact factor: 12.079

10.  Effect of overnight wear of the Triggerfish(®) sensor on corneal thickness measured by Visante(®) anterior segment optical coherence tomography.

Authors:  Ralitsa Hubanova; Florent Aptel; Christophe Chiquet; Benjamin Mottet; Jean-Paul Romanet
Journal:  Acta Ophthalmol       Date:  2013-07-15       Impact factor: 3.761

View more
  10 in total

1.  Reduction of intraocular pressure and improvement of vision after cataract surgeries in angle closure glaucoma with concomitant cataract patients.

Authors:  Zong-Mei Zhang; Qing Niu; Yan Nie; Jin Zhang
Journal:  Int J Clin Exp Med       Date:  2015-09-15

2.  Can a contact lens sensor predict the success of trabectome surgery?

Authors:  Naoki Tojo; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-03       Impact factor: 3.117

3.  Association Between 24-Hour Intraocular Pressure Monitored With Contact Lens Sensor and Visual Field Progression in Older Adults With Glaucoma.

Authors:  Carlos Gustavo De Moraes; Kaweh Mansouri; Jeffrey M Liebmann; Robert Ritch
Journal:  JAMA Ophthalmol       Date:  2018-07-01       Impact factor: 7.389

4.  Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor.

Authors:  John H K Liu; Kaweh Mansouri; Robert N Weinreb
Journal:  PLoS One       Date:  2015-06-15       Impact factor: 3.240

5.  Primary angle-closure glaucoma: A retrospective interventional case series in South India.

Authors:  H H Suresh; H R Samhitha; H Kishore; Krishna Prasad; Sneha Solse; P Divya
Journal:  Oman J Ophthalmol       Date:  2016 Jan-Apr

6.  Effect of cataract surgery on intraocular pressure in supine and lateral decubitus body postures.

Authors:  Ji-Hye Park; Chungkwon Yoo; Jong-Suk Song; Shan C Lin; Yong Yeon Kim
Journal:  Indian J Ophthalmol       Date:  2016-10       Impact factor: 1.848

7.  Factors Associated with the Retinal Nerve Fiber Layer Loss after Acute Primary Angle Closure: A Prospective EDI-OCT Study.

Authors:  Eun Ji Lee; Tae-Woo Kim; Kyoung Min Lee; Seung Hyen Lee; Hyunjoong Kim
Journal:  PLoS One       Date:  2017-01-31       Impact factor: 3.240

8.  Cataract surgery reduces intraocular pressure but not posture-induced intraocular pressure changes in patients with angle-closure glaucoma.

Authors:  Pei-Yao Chang; Jia-Kang Wang; Hsin-Yu Weng; Shu-Wen Chang
Journal:  Sci Rep       Date:  2019-10-01       Impact factor: 4.379

9.  Systematic Review and Meta-Analysis of Comparing Phacoemulsification Combined with goniosynechialysis to other mainstream procedures in treating patients with angle-closure glaucoma.

Authors:  Yang Liu; Wenjie Li; Xudong Jiu; Xunwen Lei; Lin Liu; Chengying Yan; Xiaojun Li
Journal:  Medicine (Baltimore)       Date:  2019-10       Impact factor: 1.817

Review 10.  Surgical and Perioperative Considerations for the Treatment of Cataract in Eyes with Glaucoma: A Literature Review.

Authors:  Kleonikos Tsakiris; George Kontadakis; Panagiotis Georgoudis; Zisis Gatzioufas; Athanasios Vergados
Journal:  J Ophthalmol       Date:  2021-04-26       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.