Literature DB >> 24888380

An overview of home tonometry and telemetry for intraocular pressure monitoring in humans.

Edward Yung1, Valerie Trubnik, L Jay Katz.   

Abstract

PURPOSE: To review the existing technology for self-tonometry and evaluate methods for continuous monitoring of IOP currently undergoing development and clinical trials in humans.
BACKGROUND: Glaucoma is one of the leading causes of blindness worldwide. Current glaucoma therapy is focused primarily on lowering intraocular pressures (IOP). Decisions to modify treatment regiments are primarily based on office IOP. Since IOP fluctuates throughout the day, values obtained in the office may be a poor representation of the patient's disease. IOP measurements outside of the physician's office environment would provide better knowledge of the disease state and allow for better-informed medical decision making. METHODS AND
RESULTS: We performed a literature search using Medline and IEEE database for studies investigating technologies that have been developed for continuous 24-hour IOP monitoring.
CONCLUSION: There is currently no technology that has been approved for use to allow for continuous monitoring of IOP fluctuations. New experimental technology being developed and currently undergoing clinical trials has demonstrated potential for changing the diagnosis and management of glaucoma.

Entities:  

Mesh:

Year:  2014        PMID: 24888380     DOI: 10.1007/s00417-014-2668-5

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  63 in total

1.  Ocuton-S self tonometry vs. Goldmann tonometry; a diurnal comparison study.

Authors:  P Kóthy; P Vargha; G Holló
Journal:  Acta Ophthalmol Scand       Date:  2001-06

2.  Development of a completely encapsulated intraocular pressure sensor.

Authors:  P Walter; U Schnakenberg; G vom Bögel; P Ruokonen; C Krüger; S Dinslage; H C Lüdtke Handjery; H Richter; W Mokwa; M Diestelhorst; G K Krieglstein
Journal:  Ophthalmic Res       Date:  2000 Nov-Dec       Impact factor: 2.892

3.  Tonometer utilization, accuracy, and calibration under field conditions.

Authors:  I F Wessels; Y Oh
Journal:  Arch Ophthalmol       Date:  1990-12

4.  Prototype of a nanostructured sensing contact lens for noninvasive intraocular pressure monitoring.

Authors:  Irene Sánchez; Vladimir Laukhin; Ana Moya; Raul Martin; Fernando Ussa; Elena Laukhina; Anton Guimera; Rosa Villa; Concepcio Rovira; Jordi Aguiló; Jaume Veciana; Jose C Pastor
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-21       Impact factor: 4.799

5.  Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes.

Authors:  Matteo Leonardi; Elie M Pitchon; Arnaud Bertsch; Philippe Renaud; André Mermoud
Journal:  Acta Ophthalmol       Date:  2008-11-12       Impact factor: 3.761

6.  Evaluation of the ICare rebound tonometer as a home intraocular pressure monitoring device.

Authors:  Sanjay Asrani; Ashmita Chatterjee; David K Wallace; Cecilia Santiago-Turla; Sandra Stinnett
Journal:  J Glaucoma       Date:  2011-02       Impact factor: 2.503

7.  24-hour intraocular pressure fluctuation monitoring using an ocular telemetry Sensor: tolerability and functionality in healthy subjects.

Authors:  Stefan De Smedt; André Mermoud; Corinne Schnyder
Journal:  J Glaucoma       Date:  2012 Oct-Nov       Impact factor: 2.503

8.  Sequential office pressure measurements in the management of glaucoma.

Authors:  Nanny Collaer; Thierry Zeyen; Joseph Caprioli
Journal:  J Glaucoma       Date:  2005-06       Impact factor: 2.503

9.  The number of people with glaucoma worldwide in 2010 and 2020.

Authors:  H A Quigley; A T Broman
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

10.  Intraocular pressure fluctuation a risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study.

Authors:  Joseph Caprioli; Anne L Coleman
Journal:  Ophthalmology       Date:  2008-02-20       Impact factor: 12.079

View more
  2 in total

1.  Detecting IOP Fluctuations in Glaucoma Patients.

Authors:  Brenda Nuyen; Kaweh Mansouri
Journal:  Open Ophthalmol J       Date:  2016-02-29

2.  Wearable Contact Lens Sensor for Non-invasive Continuous Monitoring of Intraocular Pressure.

Authors:  Zhiqiang Dou; Jun Tang; Zhiduo Liu; Qigong Sun; Yang Wang; Yamin Li; Miao Yuan; Huijuan Wu; Yijun Wang; Weihua Pei; Hongda Chen
Journal:  Micromachines (Basel)       Date:  2021-01-22       Impact factor: 2.891

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.