Literature DB >> 21470563

Corrosion of tungsten microelectrodes used in neural recording applications.

Erin Patrick1, Mark E Orazem, Justin C Sanchez, Toshikazu Nishida.   

Abstract

In neuroprosthetic applications, long-term electrode viability is necessary for robust recording of the activity of neural populations used for generating communication and control signals. The corrosion of tungsten microwire electrodes used for intracortical recording applications was analyzed in a controlled bench-top study and compared to the corrosion of tungsten microwires used in an in vivo study. Two electrolytes were investigated for the bench-top electrochemical analysis: 0.9% phosphate buffered saline (PBS) and 0.9% PBS containing 30 mM of hydrogen peroxide. The oxidation and reduction reactions responsible for corrosion were found by measurement of the open circuit potential and analysis of Pourbaix diagrams. Dissolution of tungsten to form the tungstic ion was found to be the corrosion mechanism. The corrosion rate was estimated from the polarization resistance, which was extrapolated from the electrochemical impedance spectroscopy data. The results show that tungsten microwires in an electrolyte of PBS have a corrosion rate of 300-700 μm/yr. The corrosion rate for tungsten microwires in an electrolyte containing PBS and 30 mM H₂O₂ is accelerated to 10,000-20,000 μm/yr. The corrosion rate was found to be controlled by the concentration of the reacting species in the cathodic reaction (e.g. O₂ and H₂O₂). The in vivo corrosion rate, averaged over the duration of implantation, was estimated to be 100 μm/yr. The reduced in vivo corrosion rate as compared to the bench-top rate is attributed to decreased rate of oxygen diffusion caused by the presence of a biological film and a reduced concentration of available oxygen in the brain.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21470563      PMCID: PMC3107924          DOI: 10.1016/j.jneumeth.2011.03.012

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  18 in total

1.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.

Authors:  J C Williams; R L Rennaker; D R Kipke
Journal:  Brain Res Brain Res Protoc       Date:  1999-12

2.  Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex.

Authors:  J K Chapin; K A Moxon; R S Markowitz; M A Nicolelis
Journal:  Nat Neurosci       Date:  1999-07       Impact factor: 24.884

Review 3.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols.

Authors:  Daniel R Merrill; Marom Bikson; John G R Jefferys
Journal:  J Neurosci Methods       Date:  2005-02-15       Impact factor: 2.390

4.  Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study.

Authors:  Justin C Sanchez; Nicolas Alba; Toshikazu Nishida; Christopher Batich; Paul R Carney
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2006-06       Impact factor: 3.802

5.  Flexible polymer substrate and tungsten microelectrode array for an implantable neural recording system.

Authors:  Erin Patrick; Viswanath Sankar; William Rowe; Sheng-Feng Yen; Justin C Sanchez; Toshikazu Nishida
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

Review 6.  Corrosion of metal orthopaedic implants.

Authors:  J J Jacobs; J L Gilbert; R M Urban
Journal:  J Bone Joint Surg Am       Date:  1998-02       Impact factor: 5.284

7.  The Utah intracortical Electrode Array: a recording structure for potential brain-computer interfaces.

Authors:  E M Maynard; C T Nordhausen; R A Normann
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1997-03

8.  Monitoring cerebral oxygenation: experimental studies and preliminary clinical results of continuous monitoring of cerebrospinal fluid and brain tissue oxygen tension.

Authors:  A I Maas; W Fleckenstein; D A de Jong; H van Santbrink
Journal:  Acta Neurochir Suppl (Wien)       Date:  1993

9.  Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex.

Authors:  Daryl R Kipke; Rio J Vetter; Justin C Williams; Jamille F Hetke
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2003-06       Impact factor: 3.802

10.  Cerebral oxygenation in contusioned vs. nonlesioned brain tissue: monitoring of PtiO2 with Licox and Paratrend.

Authors:  A S Sarrafzadeh; K L Kiening; T F Bardt; G H Schneider; A W Unterberg; W R Lanksch
Journal:  Acta Neurochir Suppl       Date:  1998
View more
  29 in total

1.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

2.  Mechanically-compliant intracortical implants reduce the neuroinflammatory response.

Authors:  Jessica K Nguyen; Daniel J Park; John L Skousen; Allison E Hess-Dunning; Dustin J Tyler; Stuart J Rowan; Christoph Weder; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2014-08-15       Impact factor: 5.379

3.  Neural Recording and Modulation Technologies.

Authors:  Ritchie Chen; Andres Canales; Polina Anikeeva
Journal:  Nat Rev Mater       Date:  2017-01-04       Impact factor: 66.308

4.  Recent Advances in Neural Electrode-Tissue Interfaces.

Authors:  Kevin Woeppel; Qianru Yang; Xinyan Tracy Cui
Journal:  Curr Opin Biomed Eng       Date:  2017-09-23

5.  Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species.

Authors:  Pavel Takmakov; Kiersten Ruda; K Scott Phillips; Irada S Isayeva; Victor Krauthamer; Cristin G Welle
Journal:  J Neural Eng       Date:  2015-01-28       Impact factor: 5.379

6.  Development of Superoxide Dismutase Mimetic Surfaces to Reduce Accumulation of Reactive Oxygen Species for Neural Interfacing Applications.

Authors:  Kelsey A Potter-Baker; Jessica K Nguyen; Kyle M Kovach; Martin M Gitomer; Tyler W Srail; Wade G Stewart; John L Skousen; Jeffrey R Capadona
Journal:  J Mater Chem B       Date:  2014-04-28       Impact factor: 6.331

7.  Materials and processing approaches for foundry-compatible transient electronics.

Authors:  Jan-Kai Chang; Hui Fang; Christopher A Bower; Enming Song; Xinge Yu; John A Rogers
Journal:  Proc Natl Acad Sci U S A       Date:  2017-06-26       Impact factor: 11.205

8.  Host tissue response to floating microelectrode arrays chronically implanted in the feline spinal nerve.

Authors:  Christi L Kolarcik; Carlos A Castro; Andrew Lesniak; Anthony J Demetris; Lee E Fisher; Robert A Gaunt; Douglas J Weber; X Tracy Cui
Journal:  J Neural Eng       Date:  2020-07-10       Impact factor: 5.379

9.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.

Authors:  James C Barrese; Naveen Rao; Kaivon Paroo; Corey Triebwasser; Carlos Vargas-Irwin; Lachlan Franquemont; John P Donoghue
Journal:  J Neural Eng       Date:  2013-11-12       Impact factor: 5.379

Review 10.  Synthetic nanoelectronic probes for biological cells and tissues.

Authors:  Bozhi Tian; Charles M Lieber
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2013-02-28       Impact factor: 10.745

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.