Literature DB >> 10592339

Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.

J C Williams1, R L Rennaker, D R Kipke.   

Abstract

This paper describes a detailed protocol for obtaining chronic, multi-site unit recordings in cerebral cortex of awake animals for periods of three months or more. The protocol includes details for making relatively simple and inexpensive implantable multichannel electrodes that consist of arrays of separate microwires. The results reported in this paper suggest that a viable implant will have discriminable unit activity on about 80% of the electrodes, resulting in, on average, the simultaneous unit recording of upwards of 60 units during a daily recording session. The active electrodes during one recording session tend to remain active in subsequent recording sessions for several weeks. Using the methods described here, implants have been constructed which incorporate several different electrode materials, coatings, sizes, and electrode separation within a single array. These microwire electrode arrays provide the basic technology for obtaining unit recordings for several months. This provides a model system for studying biocompatibility of neural implants, which is a critical component for the development of neural implants that have an indefinite working span.

Mesh:

Year:  1999        PMID: 10592339     DOI: 10.1016/s1385-299x(99)00034-3

Source DB:  PubMed          Journal:  Brain Res Brain Res Protoc        ISSN: 1385-299X


  102 in total

1.  Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications.

Authors:  Parastoo Hashemi; Paul L Walsh; Thomas S Guillot; Julie Gras-Najjar; Pavel Takmakov; Fulton T Crews; R Mark Wightman
Journal:  ACS Chem Neurosci       Date:  2011-11-16       Impact factor: 4.418

Review 2.  Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording.

Authors:  Anoop C Patil; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-11       Impact factor: 2.602

3.  Glial responses to implanted electrodes in the brain.

Authors:  Joseph W Salatino; Kip A Ludwig; Takashi D Y Kozai; Erin K Purcell
Journal:  Nat Biomed Eng       Date:  2017-11-10       Impact factor: 25.671

4.  Identification of multiple-input systems with highly coupled inputs: application to EMG prediction from multiple intracortical electrodes.

Authors:  David T Westwick; Eric A Pohlmeyer; Sara A Solla; Lee E Miller; Eric J Perreault
Journal:  Neural Comput       Date:  2006-02       Impact factor: 2.026

5.  Cuprizone-induced oligodendrocyte loss and demyelination impairs recording performance of chronically implanted neural interfaces.

Authors:  Steven M Wellman; Kelly Guzman; Kevin C Stieger; Lauren E Brink; Sadhana Sridhar; Mitchell T Dubaniewicz; Lehong Li; Franca Cambi; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-02-06       Impact factor: 12.479

6.  Long-term changes in the material properties of brain tissue at the implant-tissue interface.

Authors:  Arati Sridharan; Subramaniam D Rajan; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2013-10-08       Impact factor: 5.379

7.  Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responses.

Authors:  Andrew J Woolley; Himanshi A Desai; Kevin J Otto
Journal:  J Neural Eng       Date:  2013-02-21       Impact factor: 5.379

8.  Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain.

Authors:  Asiyeh Golabchi; Kevin M Woeppel; Xia Li; Carl F Lagenaur; X Tracy Cui
Journal:  Biosens Bioelectron       Date:  2020-02-18       Impact factor: 10.618

9.  Control protocol for robust in vitro glial scar formation around microwires: essential roles of bFGF and serum in gliosis.

Authors:  Vadim S Polikov; Eric C Su; Matthew A Ball; Jau-Shyong Hong; William M Reichert
Journal:  J Neurosci Methods       Date:  2009-05-15       Impact factor: 2.390

10.  Poly (3, 4-ethylenedioxythiophene)-ionic liquid coating improves neural recording and stimulation functionality of MEAs.

Authors:  Zhanhong Jeff Du; Xiliang Luo; Cassandra Weaver; Xinyan Tracy Cui
Journal:  J Mater Chem C Mater       Date:  2015-04-27       Impact factor: 7.393

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.