Literature DB >> 25627426

Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species.

Pavel Takmakov1, Kiersten Ruda, K Scott Phillips, Irada S Isayeva, Victor Krauthamer, Cristin G Welle.   

Abstract

OBJECTIVE: A challenge for implementing high bandwidth cortical brain-machine interface devices in patients is the limited functional lifespan of implanted recording electrodes. Development of implant technology currently requires extensive non-clinical testing to demonstrate device performance. However, testing the durability of the implants in vivo is time-consuming and expensive. Validated in vitro methodologies may reduce the need for extensive testing in animal models. APPROACH: Here we describe an in vitro platform for rapid evaluation of implant stability. We designed a reactive accelerated aging (RAA) protocol that employs elevated temperature and reactive oxygen species (ROS) to create a harsh aging environment. Commercially available microelectrode arrays (MEAs) were placed in a solution of hydrogen peroxide at 87 °C for a period of 7 days. We monitored changes to the implants with scanning electron microscopy and broad spectrum electrochemical impedance spectroscopy (1 Hz-1 MHz) and correlated the physical changes with impedance data to identify markers associated with implant failure. MAIN
RESULTS: RAA produced a diverse range of effects on the structural integrity and electrochemical properties of electrodes. Temperature and ROS appeared to have different effects on structural elements, with increased temperature causing insulation loss from the electrode microwires, and ROS concentration correlating with tungsten metal dissolution. All array types experienced impedance declines, consistent with published literature showing chronic (>30 days) declines in array impedance in vivo. Impedance change was greatest at frequencies <10 Hz, and smallest at frequencies 1 kHz and above. Though electrode performance is traditionally characterized by impedance at 1 kHz, our results indicate that an impedance change at 1 kHz is not a reliable predictive marker of implant degradation or failure. SIGNIFICANCE: ROS, which are known to be present in vivo, can create structural damage and change electrical properties of MEAs. Broad-spectrum electrical impedance spectroscopy demonstrates increased sensitivity to electrode damage compared with single-frequency measurements. RAA can be a useful tool to simulate worst-case in vivo damage resulting from chronic electrode implantation, simplifying the device development lifecycle.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25627426      PMCID: PMC5542586          DOI: 10.1088/1741-2560/12/2/026003

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  63 in total

1.  Dissolution of tungsten coils leads to device failure after transcatheter embolisation of pathologic vessels.

Authors:  M Peuster; V Kaese; G Wuensch; P Wuebbolt; M Niemeyer; R Boekenkamp; C Fink; H Haferkamp; G Hausdorf
Journal:  Heart       Date:  2001-06       Impact factor: 5.994

2.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.

Authors:  Rio J Vetter; Justin C Williams; Jamille F Hetke; Elizabeth A Nunamaker; Daryl R Kipke
Journal:  IEEE Trans Biomed Eng       Date:  2004-06       Impact factor: 4.538

Review 3.  FDA regulation of invasive neural recording electrodes: a daunting task for medical innovators.

Authors:  Cristin Welle; Victor Krauthamer
Journal:  IEEE Pulse       Date:  2012-03       Impact factor: 0.924

4.  In vivo impedance spectroscopy of deep brain stimulation electrodes.

Authors:  Scott F Lempka; Svjetlana Miocinovic; Matthew D Johnson; Jerrold L Vitek; Cameron C McIntyre
Journal:  J Neural Eng       Date:  2009-06-03       Impact factor: 5.379

Review 5.  Highly reactive oxygen species: detection, formation, and possible functions.

Authors:  Wolfhardt Freinbichler; Maria A Colivicchi; Chiara Stefanini; Loria Bianchi; Chiara Ballini; Bashkim Misini; Peter Weinberger; Wolfgang Linert; Damir Varešlija; Keith F Tipton; Laura Della Corte
Journal:  Cell Mol Life Sci       Date:  2011-05-02       Impact factor: 9.261

6.  A high-performance brain-computer interface.

Authors:  Gopal Santhanam; Stephen I Ryu; Byron M Yu; Afsheen Afshar; Krishna V Shenoy
Journal:  Nature       Date:  2006-07-13       Impact factor: 49.962

Review 7.  Active oxygen species and the functions of phagocytic leukocytes.

Authors:  J A Badwey; M L Karnovsky
Journal:  Annu Rev Biochem       Date:  1980       Impact factor: 23.643

8.  Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex.

Authors:  L Spataro; J Dilgen; S Retterer; A J Spence; M Isaacson; J N Turner; W Shain
Journal:  Exp Neurol       Date:  2005-08       Impact factor: 5.330

9.  Degradation of medical-grade polyurethane elastomers: the effect of hydrogen peroxide in vitro.

Authors:  G F Meijs; S J McCarthy; E Rizzardo; Y C Chen; R C Chatelier; A Brandwood; K Schindhelm
Journal:  J Biomed Mater Res       Date:  1993-03

10.  Neural control of computer cursor velocity by decoding motor cortical spiking activity in humans with tetraplegia.

Authors:  Sung-Phil Kim; John D Simeral; Leigh R Hochberg; John P Donoghue; Michael J Black
Journal:  J Neural Eng       Date:  2008-11-18       Impact factor: 5.379

View more
  43 in total

1.  Toward guiding principles for the design of biologically-integrated electrodes for the central nervous system.

Authors:  Cort H Thompson; Ti'Air E Riggins; Paras R Patel; Cynthia A Chestek; Wen Li; Erin Purcell
Journal:  J Neural Eng       Date:  2020-03-12       Impact factor: 5.379

Review 2.  Neural engineering: the process, applications, and its role in the future of medicine.

Authors:  Evon S Ereifej; Courtney E Shell; Jonathon S Schofield; Hamid Charkhkar; Ivana Cuberovic; Alan D Dorval; Emily L Graczyk; Takashi D Y Kozai; Kevin J Otto; Dustin J Tyler; Cristin G Welle; Alik S Widge; José Zariffa; Chet T Moritz; Dennis J Bourbeau; Paul D Marasco
Journal:  J Neural Eng       Date:  2019-11-12       Impact factor: 5.379

Review 3.  Understanding the Role of Innate Immunity in the Response to Intracortical Microelectrodes.

Authors:  John K Hermann; Jeffrey R Capadona
Journal:  Crit Rev Biomed Eng       Date:  2018

4.  Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes.

Authors:  Srikanth Vasudevan; Kunal Patel; Cristin Welle
Journal:  J Neural Eng       Date:  2016-12-09       Impact factor: 5.379

5.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

6.  Zwitterionic Polymer Coating Suppresses Microglial Encapsulation to Neural Implants In Vitro and In Vivo.

Authors:  Qianru Yang; Bingchen Wu; James R Eles; Alberto L Vazquez; Takashi D Y Kozai; X Tracy Cui
Journal:  Adv Biosyst       Date:  2020-05-04

7.  Electrodeposited platinum-iridium coating improves in vivo recording performance of chronically implanted microelectrode arrays.

Authors:  Isaac R Cassar; Chunxiu Yu; Jaydeep Sambangi; Curtis D Lee; John J Whalen; Artin Petrossians; Warren M Grill
Journal:  Biomaterials       Date:  2019-03-18       Impact factor: 12.479

8.  Recent Advances in Neural Electrode-Tissue Interfaces.

Authors:  Kevin Woeppel; Qianru Yang; Xinyan Tracy Cui
Journal:  Curr Opin Biomed Eng       Date:  2017-09-23

9.  Cuprizone-induced oligodendrocyte loss and demyelination impairs recording performance of chronically implanted neural interfaces.

Authors:  Steven M Wellman; Kelly Guzman; Kevin C Stieger; Lauren E Brink; Sadhana Sridhar; Mitchell T Dubaniewicz; Lehong Li; Franca Cambi; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-02-06       Impact factor: 12.479

10.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.