Literature DB >> 16792298

Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study.

Justin C Sanchez1, Nicolas Alba, Toshikazu Nishida, Christopher Batich, Paul R Carney.   

Abstract

Long-term viability of chronic invasive neural probes is a necessary condition for extracting robust control signals directly from neural tissue. Although immune/tissue response is a leading factor in the degradation of single neuron recording, we investigate a second component of signal degradation connected to the structural changes associated with microwire electrodes chronically exposed to extracelluar environments in vivo. Scanning electron microscopy is used to assess the surface modifications to the electrodes after an implantation duration of four weeks in rats. The electrode developed a smooth fracture surface, a reduction of the metal diameter, and pitting in the insulation of the electrode structure. Over the duration of implantation, recording properties of the electrode were marked by a reduction in the peak-to-peak amplitude in neuronal firing.

Entities:  

Mesh:

Year:  2006        PMID: 16792298     DOI: 10.1109/TNSRE.2006.875581

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  13 in total

1.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

2.  Mechanically-compliant intracortical implants reduce the neuroinflammatory response.

Authors:  Jessica K Nguyen; Daniel J Park; John L Skousen; Allison E Hess-Dunning; Dustin J Tyler; Stuart J Rowan; Christoph Weder; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2014-08-15       Impact factor: 5.379

3.  Animal Models of Posttraumatic Seizures and Epilepsy.

Authors:  Alexander V Glushakov; Olena Y Glushakova; Sylvain Doré; Paul R Carney; Ronald L Hayes
Journal:  Methods Mol Biol       Date:  2016

4.  Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species.

Authors:  Pavel Takmakov; Kiersten Ruda; K Scott Phillips; Irada S Isayeva; Victor Krauthamer; Cristin G Welle
Journal:  J Neural Eng       Date:  2015-01-28       Impact factor: 5.379

5.  Early MR diffusion and relaxation changes in the parahippocampal gyrus precede the onset of spontaneous seizures in an animal model of chronic limbic epilepsy.

Authors:  Mansi B Parekh; Paul R Carney; Hector Sepulveda; Wendy Norman; Michael King; Thomas H Mareci
Journal:  Exp Neurol       Date:  2010-04-13       Impact factor: 5.330

6.  Corrosion of tungsten microelectrodes used in neural recording applications.

Authors:  Erin Patrick; Mark E Orazem; Justin C Sanchez; Toshikazu Nishida
Journal:  J Neurosci Methods       Date:  2011-04-04       Impact factor: 2.390

7.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

8.  A symbiotic brain-machine interface through value-based decision making.

Authors:  Babak Mahmoudi; Justin C Sanchez
Journal:  PLoS One       Date:  2011-03-14       Impact factor: 3.240

9.  Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants.

Authors:  Abhishek Prasad; Qing-Shan Xue; Robert Dieme; Viswanath Sankar; Roxanne C Mayrand; Toshikazu Nishida; Wolfgang J Streit; Justin C Sanchez
Journal:  Front Neuroeng       Date:  2014-02-04

10.  Influence of neuropathology on convection-enhanced delivery in the rat hippocampus.

Authors:  Svetlana Kantorovich; Garrett W Astary; Michael A King; Thomas H Mareci; Malisa Sarntinoranont; Paul R Carney
Journal:  PLoS One       Date:  2013-11-08       Impact factor: 3.240

View more