Literature DB >> 21357951

The relationship between the angle of version and rate of wear of retrieved metal-on-metal resurfacings: a prospective, CT-based study.

A J Hart1, K Ilo, R Underwood, P Cann, J Henckel, A Lewis, J Cobb, J Skinner.   

Abstract

We measured the orientation of the acetabular and femoral components in 45 patients (33 men, 12 women) with a mean age of 53.4 years (30 to 74) who had undergone revision of metal-on-metal hip resurfacings. Three-dimensional CT was used to measure the inclination and version of the acetabular component, femoral version and the horizontal femoral offset, and the linear wear of the removed acetabular components was measured using a roundness machine. We found that acetabular version and combined version of the acetabular and femoral components were weakly positively correlated with the rate of wear. The acetabular inclination angle was strongly positively correlated with the rate of wear. Femoral version was weakly negatively correlated with the rate of wear. Application of a threshold of > 5 μm/year for the rate of wear in order to separate the revisions into low or high wearing groups showed that more high wearing components were implanted outside Lewinnek's safe zone, but that this was mainly due to the inclination of the acetabular component, which was the only parameter that significantly differed between the groups. We were unable to show that excess version of the acetabular component alone or combined with femoral version was associated with an increase in the rate of wear based on our assessment of version using CT.

Entities:  

Mesh:

Year:  2011        PMID: 21357951     DOI: 10.1302/0301-620X.93B3.25545

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  21 in total

1.  Robotic assisted total hip arthroplasty using the MAKO platform.

Authors:  Rupesh Tarwala; Lawrence D Dorr
Journal:  Curr Rev Musculoskelet Med       Date:  2011-09

2.  A comparison of two different navigated hip replacement techniques on leg length discrepancy.

Authors:  T N Jennison; P Craig; Edward D Davis
Journal:  J Orthop       Date:  2018-02-21

3.  Accuracy of the modified Hardinge approach in acetabular positioning.

Authors:  Prateek Goyal; Adrian Lau; Richard McCalden; Matthew G Teeter; James L Howard; Brent A Lanting
Journal:  Can J Surg       Date:  2016-08       Impact factor: 2.089

4.  Difference in the acetabular cup orientation in standing and supine radiographs.

Authors:  Munir Khan; Tom Beckingsale; Martin Marsh; Jim Holland
Journal:  J Orthop       Date:  2016-04-05

5.  Prevalence of dysplasia as the source of worse outcome in young female patients after hip resurfacing arthroplasty.

Authors:  Thomas P Gross; Fei Liu
Journal:  Int Orthop       Date:  2011-06-07       Impact factor: 3.075

Review 6.  Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation.

Authors:  Ming Han Lincoln Liow; Young-Min Kwon
Journal:  Int Orthop       Date:  2016-10-20       Impact factor: 3.075

7.  Pseudotumors are common in well-positioned low-wearing metal-on-metal hips.

Authors:  Ashley K Matthies; John A Skinner; Humza Osmani; Johann Henckel; Alister J Hart
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

Review 8.  Management of metal-on-metal hip implant patients: Who, when and how to revise?

Authors:  Reshid Berber; John A Skinner; Alister J Hart
Journal:  World J Orthop       Date:  2016-05-18

9.  What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?

Authors:  Nick Bayley; Habeeb Khan; Paul Grosso; Thomas Hupel; David Stevens; Matthew Snider; Emil Schemitsch; Paul Kuzyk
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

10.  What causes unexplained pain in patients with metal-on metal hip devices? A retrieval, histologic, and imaging analysis.

Authors:  Danyal H Nawabi; Nader A Nassif; Huong T Do; Kirsten Stoner; Marcella Elpers; Edwin P Su; Timothy Wright; Hollis G Potter; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.