Literature DB >> 27190754

Management of metal-on-metal hip implant patients: Who, when and how to revise?

Reshid Berber1, John A Skinner1, Alister J Hart1.   

Abstract

The debate on how best to manage patients with metal-on-metal (MOM) hip implants continues. With over 1 million patients affected worldwide, the impact is far reaching. The majority of the aggressive failures of MOM hip implants have been dealt with by revision hip surgery, leaving patients with a much more indolent pattern of failure of devices that have been in situ for more than 10 years. The longer-term outcome for such patients remains unknown, and much debate exists on how best to manage these patients. Regulatory guidance is available but remains open to interpretation due to the lack of current evidence and long-term studies. Metal ion thresholds for concern have been suggested at 7 ppb for hip resurfacing arthroplasty and below this level for large diameter total hip arthroplasties. Soft tissue changes including pseudotumours and muscle atrophy have been shown to progress, but this is not consistent. New advanced imaging techniques are helping to diagnose complications with metal hips and the reasons for failure, however these are not widely available. This has led to some centres to tackle difficult cases through multidisciplinary collaboration, for both surgical management decisions and also follow-up decisions. We summarise current evidence and consider who is at risk, when revision should be undertaken and how patients should be managed.

Entities:  

Keywords:  Decision; Management; Metal on metal hip; Multi-disciplinary; Revision

Year:  2016        PMID: 27190754      PMCID: PMC4865716          DOI: 10.5312/wjo.v7.i5.272

Source DB:  PubMed          Journal:  World J Orthop        ISSN: 2218-5836


  63 in total

1.  "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study.

Authors:  Young-Min Kwon; Simon J Ostlere; Peter McLardy-Smith; Nicholas A Athanasou; Harinderjit S Gill; David W Murray
Journal:  J Arthroplasty       Date:  2010-06-29       Impact factor: 4.757

2.  Hip resurfacings revised for inflammatory pseudotumour have a poor outcome.

Authors:  G Grammatopoulos; G Grammatopolous; H Pandit; Y-M Kwon; R Gundle; P McLardy-Smith; D J Beard; D W Murray; H S Gill
Journal:  J Bone Joint Surg Br       Date:  2009-08

3.  Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society.

Authors:  Young-Min Kwon; Adolph V Lombardi; Joshua J Jacobs; Thomas K Fehring; Courtland G Lewis; Miguel E Cabanela
Journal:  J Bone Joint Surg Am       Date:  2014-01-01       Impact factor: 5.284

4.  Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement.

Authors:  A J Hart; S A Sabah; A S Bandi; P Maggiore; P Tarassoli; B Sampson; J A Skinner
Journal:  J Bone Joint Surg Br       Date:  2011-10

Review 5.  Systemic toxicity related to metal hip prostheses.

Authors:  S M Bradberry; J M Wilkinson; R E Ferner
Journal:  Clin Toxicol (Phila)       Date:  2014-08-16       Impact factor: 4.467

6.  Widespread dissemination of metal debris from implants.

Authors:  C P Case; V G Langkamer; C James; M R Palmer; A J Kemp; P F Heap; L Solomon
Journal:  J Bone Joint Surg Br       Date:  1994-09

7.  Pseudotumours associated with metal-on-metal hip resurfacings.

Authors:  H Pandit; S Glyn-Jones; P McLardy-Smith; R Gundle; D Whitwell; C L M Gibbons; S Ostlere; N Athanasou; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-07

8.  Predicting wear and blood metal ion levels in metal-on-metal hip resurfacing.

Authors:  Ashley K Matthies; Johann Henckel; Suzie Cro; Alexander Suarez; Philip C Noble; John Skinner; Alister J Hart
Journal:  J Orthop Res       Date:  2013-09-21       Impact factor: 3.494

9.  Edge loading in metal-on-metal hips: low clearance is a new risk factor.

Authors:  Richard J Underwood; Angelos Zografos; Ritchie S Sayles; Alister Hart; Philippa Cann
Journal:  Proc Inst Mech Eng H       Date:  2012-03       Impact factor: 1.617

10.  A comparison of the diagnostic accuracy of MARS MRI and ultrasound of the painful metal-on-metal hip arthroplasty.

Authors:  Imran A Siddiqui; Shiraz A Sabah; Keshthra Satchithananda; Adrian K Lim; Suzie Cro; Johann Henckel; John A Skinner; Alister J Hart
Journal:  Acta Orthop       Date:  2014-04-03       Impact factor: 3.717

View more
  5 in total

1.  Pleomorphic clinical spectrum of metallosis in total hip arthroplasty.

Authors:  Francesco Pisanu; Carlo Doria; Matteo Andreozzi; Marco Bartoli; Laura Saderi; Giovanni Sotgiu; Paolo Tranquilli Leali
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

2.  Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations.

Authors:  James H Ho; Jerrold B Leikin; Paul I Dargan; John R H Archer; David M Wood; Jeffrey Brent
Journal:  J Med Toxicol       Date:  2017-09-12

3.  Molecular pathology of adverse local tissue reaction caused by metal-on-metal implants defined by RNA-seq.

Authors:  Christopher G Salib; Eric A Lewallen; Christopher R Paradise; Meagan E Tibbo; Joseph X Robin; William H Trousdale; Logan M Morrey; Jason Xiao; Travis W Turner; Afton K Limberg; Anthony G Jay; Roman Thaler; Amel Dudakovic; Joaquin Sanchez-Sotelo; Mark E Morrey; Daniel J Berry; David G Lewallen; Andre J van Wijnen; Matthew P Abdel
Journal:  Genomics       Date:  2018-09-21       Impact factor: 5.736

Review 4.  Prosthetic hip-associated cobalt toxicity: a systematic review of case series and case reports.

Authors:  J R W Crutsen; M C Koper; J Jelsma; M Heymans; I C Heyligers; B Grimm; N M C Mathijssen; M G M Schotanus
Journal:  EFORT Open Rev       Date:  2022-03-17

5.  Follow-up of Metal-on-Metal Hip Replacements at a Large District Hospital and the Implementation of Medicines and Healthcare Products Regulatory Agency Guidelines: A Review of 297 Patients.

Authors:  Luke Hughes; Kathryn Chamberlain; Heather Robinson; Andrew Sloan; Qaisar Choudry
Journal:  Clin Orthop Surg       Date:  2019-11-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.