Literature DB >> 21331594

High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: in-stent restenosis assessment by low-dose MDCT.

Daniele Andreini1, Gianluca Pontone, Antonio L Bartorelli, Saima Mushtaq, Daniela Trabattoni, Erika Bertella, Sarah Cortinovis, Andrea Annoni, Alberto Formenti, Giovanni Ballerini, Piergiuseppe Agostoni, Cesare Fiorentini, Mauro Pepi.   

Abstract

OBJECTIVES: The accuracy of computed tomography (CT) for assessment of coronary stents is as yet unproven and radiation exposure has been a concern. The aim of our study is to compare radiation dose and diagnostic performance of CT with prospective ECG-triggering versus retrospective ECG-triggering for the detection of in-stent restenosis (ISR).
METHODS: We enrolled 168 consecutive patients with suspected ISR, 83 studied using CT with prospective ECG-triggering (group 1) and 85 using retrospective ECG-triggering (group 2).
RESULTS: Prevalence of ISR according to catheter angiography was 24% in both groups. The overall evaluability was similar (93% in group 1 vs 95% in group 2). Artefact sub-analysis showed a significantly lower number of blooming and higher number of slice misalignment in group 1 vs group 2. In the stent-based analysis using only evaluable stents, specificity, positive predictive value and accuracy were significantly higher in group 1 (100%, 100% and 99%, respectively) than in group 2 (97%, 91% and 95%, respectively, p < 0.05). Group 1 was exposed to a lower radiation dose compared with group 2 (4.3 ± 1.4 mSv vs 18.5 ± 5.5 mSv, p < 00.1).
CONCLUSIONS: CT with prospective ECG-triggering can improve diagnostic accuracy of non-invasive imaging of coronary stents with a significant reduction in radiation exposure.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21331594     DOI: 10.1007/s00330-011-2085-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

Review 1.  Computed tomography coronary angiography.

Authors:  Stephan Achenbach
Journal:  J Am Coll Cardiol       Date:  2006-11-01       Impact factor: 24.094

2.  Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography.

Authors:  Jiang Hsieh; John Londt; Melissa Vass; Jay Li; Xiangyang Tang; Darin Okerlund
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

3.  Effect of dose-reduced scan protocols on cardiac coronary image quality with 64-row MDCT: a cardiac phantom study.

Authors:  Xiaolu Fei; Xiangying Du; Pengyu Li; Jingmin Liao; Yun Shen; Kuncheng Li
Journal:  Eur J Radiol       Date:  2007-08-31       Impact factor: 3.528

4.  Comparison of feasibility and diagnostic accuracy of 64-slice multidetector computed tomographic coronary angiography versus invasive coronary angiography versus intravascular ultrasound for evaluation of in-stent restenosis.

Authors:  Daniele Andreini; Gianluca Pontone; Antonio L Bartorelli; Daniela Trabattoni; Saima Mushtaq; Erika Bertella; Andrea Annoni; Alberto Formenti; Sarah Cortinovis; Piero Montorsi; Fabrizio Veglia; Giovanni Ballerini; Mauro Pepi
Journal:  Am J Cardiol       Date:  2009-03-25       Impact factor: 2.778

5.  Dose performance and image quality: dual source CT versus single source CT in cardiac CT angiography.

Authors:  Min Wang; Heng-Tao Qi; Xi-Ming Wang; Tao Wang; Jiu-Hong Chen; Cheng Liu
Journal:  Eur J Radiol       Date:  2008-10-02       Impact factor: 3.528

6.  Long-term outcome of patients with silent versus symptomatic ischemia six months after percutaneous coronary intervention and stenting.

Authors:  Michael J Zellweger; Markus Weinbacher; Andreas W Zutter; Raban V Jeger; Jan Mueller-Brand; Christoph Kaiser; Peter T Buser; Matthias E Pfisterer
Journal:  J Am Coll Cardiol       Date:  2003-07-02       Impact factor: 24.094

Review 7.  Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement.

Authors:  Claudio Marcassa; Jeroen J Bax; Frank Bengel; Birger Hesse; Claus L Petersen; Eliana Reyes; Richard Underwood
Journal:  Eur Heart J       Date:  2008-01-17       Impact factor: 29.983

8.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

9.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

10.  Dual source coronary computed tomography angiography for detecting in-stent restenosis.

Authors:  F Pugliese; A C Weustink; C Van Mieghem; F Alberghina; M Otsuka; W B Meijboom; N van Pelt; N R Mollet; F Cademartiri; G P Krestin; M G M Hunink; P J de Feyter
Journal:  Heart       Date:  2007-09-19       Impact factor: 5.994

View more
  7 in total

1.  CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction.

Authors:  Ullrich Ebersberger; Francesco Tricarico; U Joseph Schoepf; Philipp Blanke; J Reid Spears; Garrett W Rowe; William T Halligan; Thomas Henzler; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2012-07-10       Impact factor: 5.315

2.  Initial exploration of coronary stent image subtraction using dual-layer spectral CT.

Authors:  Le Qin; ShengJia Gu; ChiHua Chen; Huan Zhang; ZhenBin Zhu; XingBiao Chen; Qun Han; FuHua Yan; WenJie Yang
Journal:  Eur Radiol       Date:  2019-01-21       Impact factor: 5.315

3.  Diagnostic performance of computed tomography angiography in the detection of coronary artery in-stent restenosis: evidence from an updated meta-analysis.

Authors:  Tao Dai; Jiang-Rong Wang; Peng-Fei Hu
Journal:  Eur Radiol       Date:  2017-11-09       Impact factor: 5.315

4.  Prognostic value of dual-source multidetector computed tomography coronary angiography in patients with stent implantation.

Authors:  Hamza Sunman; Hikmet Yorgun; Uğur Canpolat; Ayşegül Ülgen Kunak; Muhammet Dural; Tuncay Hazırolan; Levent Sahiner; Ergün Barış Kaya; Kudret Aytemir; Lale Tokgözoğlu; Giray Kabakçı; Ali Oto
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-12       Impact factor: 2.357

5.  Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT.

Authors:  David Viladés Medel; Rubén Leta; Xavier Alomar Serralach; Francesc Carreras Costa; Guillem Pons-Lladó
Journal:  Eur Radiol       Date:  2015-12-10       Impact factor: 5.315

6.  CT Imaging of Coronary Stents: Past, Present, and Future.

Authors:  Andreas H Mahnken
Journal:  ISRN Cardiol       Date:  2012-09-11

7.  Performance of dual-source CT with high pitch spiral mode for coronary stent patency compared with invasive coronary angiography.

Authors:  Xia Yang; Qiang Yu; Wei Dong; Zhen-Hong Fu; Jun-Jue Yang; Jun Guo; Yun-Dai Chen
Journal:  J Geriatr Cardiol       Date:  2016-10       Impact factor: 3.327

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.