Initial exploration of coronary stent image subtraction using dual-layer spectral CT.

Le Qin1, ShengJia Gu1, ChiHua Chen1, Huan Zhang1, ZhenBin Zhu2, XingBiao Chen3, Qun Han3, FuHua Yan1, WenJie Yang4.   

Abstract

OBJECTIVES: This study aimed to investigate the feasibility of coronary stent image subtraction using spectral tools derived from dual-layer spectral computed tomography (CT).
METHODS: Forty-three patients (65 stents) who underwent coronary CT angiography using dual-layer spectral CT were included. Conventional, 50-keV (kilo electron-volt), 100-keV, and virtual non-contrast (VNC) images were reconstructed from the same cardiac phase. Stents were subtracted on VNC images from conventional (convsub), 100-keV (100-keVsub), and 50-keV (50-keVsub) images. The in-stent lumen diameters were measured on subtraction, conventional, and 100-keV images. Subjective evaluation of reader confidence and subtractive quality was evaluated. Friedman tests were performed to compare in-stent lumen diameters and subjective evaluation among different images. Correlation between stent diameter and subjective evaluation was expressed as Spearman's rank correlation coefficient (rs). The diagnostic accuracy was assessed according to invasive coronary angiography (ICA) performed in 11 patients (20 stents).
RESULTS: In-stent lumen diameters were significantly larger on subtraction images than those on conventional and 100-keV images (p < 0.05). Higher reader confidence was found on 100-keV, convsub, 100-keVsub, and 50-keVsub images compared with conventional images (p < 0.05). Subtractive quality of 100-keVsub images was better than that of convsub images (p = 0.037). A moderate-to-strong correlation between stent diameter and subjective evaluation was found (rs = 0.527~0.790, p < 0.05). Higher specificity, positive predictive value, and negative predictive value of subtraction images were shown by ICA results.
CONCLUSIONS: Subtraction images derived from dual-layer spectral CT enhanced in-stent lumen visibility and could potentially improve diagnostic performance for evaluating coronary stents. KEY POINTS: • Dual-layer spectral CT enabled good subtractive quality of coronary stents without misregistration artifacts. • Subtraction images could improve in-stent lumen visibility. • Reader confidence and diagnostic performance were enhanced with subtraction images.

Entities:  

Keywords:  Computed tomography angiography; Stents; Subtraction technique

Mesh:

Year:  2019        PMID: 30666447     DOI: 10.1007/s00330-018-5990-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction.

Authors:  Ullrich Ebersberger; Francesco Tricarico; U Joseph Schoepf; Philipp Blanke; J Reid Spears; Garrett W Rowe; William T Halligan; Thomas Henzler; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2012-07-10       Impact factor: 5.315

2.  Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed.

Authors:  Jan Kottner; Laurent Audigé; Stig Brorson; Allan Donner; Byron J Gajewski; Asbjørn Hróbjartsson; Chris Roberts; Mohamed Shoukri; David L Streiner
Journal:  J Clin Epidemiol       Date:  2010-06-17       Impact factor: 6.437

3.  Virtual nonenhanced dual-energy CT urography with tin-filter technology: determinants of detection of urinary calculi in the renal collecting system.

Authors:  Stefanie Mangold; Christoph Thomas; Michael Fenchel; Morten Vuust; Bernhard Krauss; Dominik Ketelsen; Ilias Tsiflikas; Claus D Claussen; Martin Heuschmid
Journal:  Radiology       Date:  2012-05-08       Impact factor: 11.105

4.  Is coronary stent assessment improved with spectral analysis of dual energy CT?

Authors:  Ethan J Halpern; David J Halpern; Jeffrey H Yanof; Sigal Amin-Spector; David Fischman; Galit Aviram; Jacob Sosna
Journal:  Acad Radiol       Date:  2009-06-11       Impact factor: 3.173

5.  High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: in-stent restenosis assessment by low-dose MDCT.

Authors:  Daniele Andreini; Gianluca Pontone; Antonio L Bartorelli; Saima Mushtaq; Daniela Trabattoni; Erika Bertella; Sarah Cortinovis; Andrea Annoni; Alberto Formenti; Giovanni Ballerini; Piergiuseppe Agostoni; Cesare Fiorentini; Mauro Pepi
Journal:  Eur Radiol       Date:  2011-02-18       Impact factor: 5.315

6.  Evaluation of virtual unenhanced CT obtained from dual-energy CT urography for detecting urinary stones.

Authors:  J W Moon; B K Park; C K Kim; S Y Park
Journal:  Br J Radiol       Date:  2011-09-06       Impact factor: 3.039

7.  Performance of dual source versus 256-slice multi-slice CT in the evaluation of 16 coronary artery stents.

Authors:  Florian André; Grigorios Korosoglou; Waldemar Hosch; Evangelos Giannitsis; Hans-Ulrich Kauczor; Hugo A Katus; Henning Steen
Journal:  Eur J Radiol       Date:  2012-12-30       Impact factor: 3.528

8.  When to use agreement versus reliability measures.

Authors:  Henrica C W de Vet; Caroline B Terwee; Dirk L Knol; Lex M Bouter
Journal:  J Clin Epidemiol       Date:  2006-08-10       Impact factor: 6.437

Review 9.  Head-to-head comparison of prospectively triggered vs retrospectively gated coronary computed tomography angiography: Meta-analysis of diagnostic accuracy, image quality, and radiation dose.

Authors:  Jan Menke; Christina Unterberg-Buchwald; Wieland Staab; Jan Martin Sohns; Ali Seif Amir Hosseini; Alexander Schwarz
Journal:  Am Heart J       Date:  2012-11-26       Impact factor: 4.749

10.  Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

Authors:  David Maintz; Matthias C Burg; Harald Seifarth; Alexander C Bunck; Murat Ozgün; Roman Fischbach; Kai Uwe Jürgens; Walter Heindel
Journal:  Eur Radiol       Date:  2008-08-06       Impact factor: 5.315

View more
  1 in total

1.  Iodine-based extracellular volume for evaluating myocardial status in patients undergoing percutaneous coronary intervention for acute myocardial infarction by using dual-layer spectral detector computed tomography: a comparison study with magnetic resonance.

Authors:  Jing Liang; Hui Li; Jun Xie; Hongming Yu; Wenping Chen; Kejie Yin; Xingbiao Chen; Zhihong Sheng; Xin Zhang; Dan Mu
Journal:  Quant Imaging Med Surg       Date:  2022-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.