1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

G A Wright1, B S Hu, A Macovski.   

Abstract

The use of magnetic resonance (MR) imaging is investigated for noninvasively estimating the oxygen saturation of human blood (%HbO2) in vivo by means of relaxation characteristics identified in earlier MR spectrometry studies. To this end, a sequence is presented for determining the T2 of vascular blood in regions in which motions of the body and of the blood itself present a major challenge. With use of this sequence on a commercial 1.5-T whole-body imager, the relationship between the T2 and %HbO2 of blood is calibrated in vitro for the conditions expected in vivo. T2 varies predictably from about 30 to 250 msec as %HbO2 varies from 30% to 96%. T2 values measured in situ for vascular blood in the mediastinum of several healthy subjects qualitatively reflected the behavior observed in vitro. Estimates of %HbO2 for these vessels obtained with the in vitro calibration appear reasonable, particularly for venous blood, although difficulties arise in selecting the appropriate calibration factors. These encouraging initial results support a more systematic study of potential sources of error and an examination of the accuracy of in vivo measurements by comparison with direct measurements of %HbO2 in vessels.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1802140     DOI: 10.1002/jmri.1880010303

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  103 in total

1.  Quantitative measurements of cerebral blood oxygen saturation using magnetic resonance imaging.

Authors:  H An; W Lin
Journal:  J Cereb Blood Flow Metab       Date:  2000-08       Impact factor: 6.200

2.  Investigating the magnetic susceptibility properties of fresh human blood for noninvasive oxygen saturation quantification.

Authors:  Varsha Jain; Osheiza Abdulmalik; Kathleen Joy Propert; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

Review 3.  Magnetic resonance imaging quantification of liver iron.

Authors:  Claude B Sirlin; Scott B Reeder
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-08       Impact factor: 2.266

4.  Basic principles of magnetic resonance angiography.

Authors:  R R Edelman
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

5.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

Review 6.  Biophysical and physiological origins of blood oxygenation level-dependent fMRI signals.

Authors:  Seong-Gi Kim; Seiji Ogawa
Journal:  J Cereb Blood Flow Metab       Date:  2012-03-07       Impact factor: 6.200

7.  MRI estimation of global brain oxygen consumption rate.

Authors:  Varsha Jain; Michael C Langham; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2010-04-21       Impact factor: 6.200

8.  Oxygen metabolism in ischemic stroke using magnetic resonance imaging.

Authors:  Hongyu An; Qingwei Liu; Yasheng Chen; Katie D Vo; Andria L Ford; Jin-Moo Lee; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-13       Impact factor: 6.829

9.  In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

Authors:  Michael C Langham; Ana E Rodríguez-Soto; Nadav Schwartz; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-09-03       Impact factor: 4.668

Review 10.  Time-resolved MRI oximetry for quantifying CMRO(2) and vascular reactivity.

Authors:  Felix W Wehrli; Zachary B Rodgers; Varsha Jain; Michael C Langham; Cheng Li; Daniel J Licht; Jeremy Magland
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.