Literature DB >> 17191227

Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state.

Xiang He1, Dmitriy A Yablonskiy.   

Abstract

Since Ogawa et al. (Proc Natl Acad Sci USA 1990;87:9868-9872) made the fundamental discovery of blood oxygenation level-dependent (BOLD) contrast in MRI, most efforts have been directed toward the study of dynamic BOLD (i.e., temporal changes in the MRI signal during changes in brain activity). However, very little progress has been made in elucidating the nature of BOLD contrast during the resting or baseline state of the brain, which is important for understanding normal human performance because it accounts for most of the enormous energy budget of the brain. It is also crucial for deciphering the consequences of baseline-state impairment by cerebral vascular diseases. The objective of this study was to develop a BOLD MR-based method that allows quantitative evaluation of tissue hemodynamic parameters, such as the blood volume, deoxyhemoglobin concentration, and oxygen extraction fraction (OEF). The proposed method, which we have termed quantitative BOLD (qBOLD), is based on an MR signal model that incorporates prior knowledge about brain tissue composition and considers signals from gray matter (GM), white matter (WM), cerebrospinal fluid (CSF), and blood. A 2D gradient-echo sampling of spin-echo (GESSE) pulse sequence is used for the acquisition of the MRI signal. The method is applied to estimate the hemodynamic parameters of the normal human brain in the baseline state.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17191227      PMCID: PMC3971521          DOI: 10.1002/mrm.21108

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  46 in total

1.  Analytical model of susceptibility-induced MR signal dephasing: effect of diffusion in a microvascular network.

Authors:  V G Kiselev; S Posse
Journal:  Magn Reson Med       Date:  1999-03       Impact factor: 4.668

2.  Automated correction of unwanted phase jumps in reference signals which corrupt MRSI spectra after eddy current correction.

Authors:  A W Simonetti; W J Melssen; M van der Graaf; A Heerschap; L M C Buydens
Journal:  J Magn Reson       Date:  2002-12       Impact factor: 2.229

Review 3.  Neurovascular regulation in the normal brain and in Alzheimer's disease.

Authors:  Costantino Iadecola
Journal:  Nat Rev Neurosci       Date:  2004-05       Impact factor: 34.870

4.  Rescuing troubled vessels in Alzheimer disease.

Authors:  Costantino Iadecola
Journal:  Nat Med       Date:  2005-09       Impact factor: 53.440

5.  Structure of the water resonance in small voxels in rat brain detected with high spectral and spatial resolution MRI.

Authors:  Xiaobing Fan; Weiliang Du; Peter MacEneaney; Marta Zamora; Gregory Karczmar
Journal:  J Magn Reson Imaging       Date:  2002-11       Impact factor: 4.813

6.  In vivo determination of cerebral blood volume with radioactive oxygen-15 in the monkey.

Authors:  J O Eichling; M E Raichle; R L Grubb; K B Larson; M M Ter-Pogossian
Journal:  Circ Res       Date:  1975-12       Impact factor: 17.367

Review 7.  Cerebral hemodynamic impairment: methods of measurement and association with stroke risk.

Authors:  C P Derdeyn; R L Grubb; W J Powers
Journal:  Neurology       Date:  1999-07-22       Impact factor: 9.910

Review 8.  Searching for a baseline: functional imaging and the resting human brain.

Authors:  D A Gusnard; M E Raichle; M E Raichle
Journal:  Nat Rev Neurosci       Date:  2001-10       Impact factor: 34.870

9.  Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: effects of magnetic field variation.

Authors:  Hongyu An; Weili Lin
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

10.  Cerebral venous and arterial blood volumes can be estimated separately in humans using magnetic resonance imaging.

Authors:  Hongyu An; Weili Lin
Journal:  Magn Reson Med       Date:  2002-10       Impact factor: 4.668

View more
  165 in total

1.  Nonexponential T₂ decay in white matter.

Authors:  Peter van Gelderen; Jacco A de Zwart; Jongho Lee; Pascal Sati; Daniel S Reich; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

2.  Is T2* enough to assess oxygenation? Quantitative blood oxygen level-dependent analysis in brain tumor.

Authors:  Thomas Christen; Benjamin Lemasson; Nicolas Pannetier; Regine Farion; Chantal Remy; Greg Zaharchuk; Emmanuel L Barbier
Journal:  Radiology       Date:  2011-12-09       Impact factor: 11.105

3.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

4.  Optimization strategies for evaluation of brain hemodynamic parameters with qBOLD technique.

Authors:  Xiaoqi Wang; Alexander L Sukstanskii; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2012-05-23       Impact factor: 4.668

5.  MRI estimation of global brain oxygen consumption rate.

Authors:  Varsha Jain; Michael C Langham; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2010-04-21       Impact factor: 6.200

6.  Gradient echo plural contrast imaging--signal model and derived contrasts: T2*, T1, phase, SWI, T1f, FST2*and T2*-SWI.

Authors:  Jie Luo; Bharathi D Jagadeesan; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Neuroimage       Date:  2012-01-28       Impact factor: 6.556

7.  MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain.

Authors:  T Christen; N A Pannetier; W W Ni; D Qiu; M E Moseley; N Schuff; G Zaharchuk
Journal:  Neuroimage       Date:  2013-12-07       Impact factor: 6.556

8.  Oxygen metabolism in ischemic stroke using magnetic resonance imaging.

Authors:  Hongyu An; Qingwei Liu; Yasheng Chen; Katie D Vo; Andria L Ford; Jin-Moo Lee; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-13       Impact factor: 6.829

9.  Noninvasive Measurements of Cerebral Blood Flow, Oxygen Extraction Fraction, and Oxygen Metabolic Index in Human with Inhalation of Air and Carbogen using Magnetic Resonance Imaging.

Authors:  Hongyu An; Souvik Sen; Yasheng Chen; William J Powers; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-28       Impact factor: 6.829

10.  On the role of neuronal magnetic susceptibility and structure symmetry on gradient echo MR signal formation.

Authors:  Alexander L Sukstanskii; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2013-02-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.