Literature DB >> 7355433

Carotid artery velocity patterns in normal and stenotic vessels.

W M Blackshear, D J Phillips, P M Chikos, J D Harley, B L Thiele, D E Strandness.   

Abstract

Duplex scanning provides real time B-mode images of the carotid bifurcation vessels along with a single gate pulsed Doppler flow velocity detector. By using the B-mode output of the duplex system to measure the Doppler angle and spectrum analysis to measure the frequency content of the Doppler signal, instantaneous flow velocity can be calculated. Mean velocity at peak systole was calculated retrospectively in 68 common (CCA) and internal (ICA) carotid arteries of 39 patients who had undergone prior angiography and prospectively in 30 arteries of 15 healthy young controls. The ratio of mean peak ICA velocity to mean peak CCA velocity at systole (VICA/VCCA) was below 0.8 in all 36 normal arteries and above 1.5 in all 21 high-grade stenoses of 60% or greater diameter reduction. Sixty-one percent of 41 vessels with less than 10 to 55% diameter reduction had a velocity ratio between 0.8 and 1.5. Only 10% of all ICA's with any stenotic lesion were incorrectly classified as normal. VICA/VCCA appears to be an accurate indicator of the degree of ICA stenosis.

Entities:  

Mesh:

Year:  1980        PMID: 7355433     DOI: 10.1161/01.str.11.1.67

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  18 in total

1.  Blood flow velocity waveform in the common carotid artery and its analysis in elderly subjects.

Authors:  I Nagatomo; M Nomaguchi; K Matsumoto
Journal:  Clin Auton Res       Date:  1992-06       Impact factor: 4.435

Review 2.  Clinical, radiological, and functional evaluation following acute stroke.

Authors:  D G Grosset
Journal:  Br J Clin Pharmacol       Date:  1992-12       Impact factor: 4.335

3.  Changes of time-attenuation curve blood flow parameters in patients with and without carotid stenosis.

Authors:  C-J Lin; F-C Chang; W-Y Guo; S-C Hung; C-B Luo; J Beilner; M Kowarschik; W-F Chu
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-26       Impact factor: 3.825

4.  Reproducibility of Doppler blood flow velocity waveform measurements: study on variability within and between day and during haemodynamic intervention in normal subjects.

Authors:  G H Rimoy; N K Bhaskar; P C Rubin
Journal:  Eur J Clin Pharmacol       Date:  1991       Impact factor: 2.953

5.  Carotid duplex ultrasound and transcranial Doppler findings in commercial divers and pilots.

Authors:  Banafshe Dormanesh; Kia Vosoughi; Fahimeh H Akhoundi; Masoud Mehrpour; Seyed-Mohammad Fereshtehnejad; Setareh Esmaeili; Azin Shafiee Sabet
Journal:  Neurol Sci       Date:  2016-07-26       Impact factor: 3.307

6.  Detection of low-grade arterial stenosis using an automatic minimum-flow-velocity tracking system (MVTS) as an adjunct to pulsed ultrasonic Doppler vessel imaging.

Authors:  S J Calil; V C Roberts
Journal:  Med Biol Eng Comput       Date:  1985-07       Impact factor: 2.602

7.  Duplex carotid ultrasound.

Authors:  J D Acker; C A Cole; K A Mauney; D M Joly; J E Machin
Journal:  Neuroradiology       Date:  1986       Impact factor: 2.804

8.  Can clinical evaluation and noninvasive testing substitute for arteriography in the evaluation of carotid artery disease?

Authors:  W S Moore; S Ziomek; W J Quiñones-Baldrich; H I Machleder; R W Busuttil; J D Baker
Journal:  Ann Surg       Date:  1988-07       Impact factor: 12.969

9.  The superiority of combined continuous wave Doppler examination over periorbital Doppler for the detection of extracranial carotid disease.

Authors:  U Trockel; M Hennerici; A Aulich; W Sandmann
Journal:  J Neurol Neurosurg Psychiatry       Date:  1984-01       Impact factor: 10.154

10.  Carotid Doppler evaluation in cerebrovascular disease.

Authors:  R N Rankin; L Hutton; C D'Alotto
Journal:  Can Med Assoc J       Date:  1984-03-15       Impact factor: 8.262

View more