Literature DB >> 26900759

On-resonance variable delay multipulse scheme for imaging of fast-exchanging protons and semisolid macromolecules.

Jiadi Xu1,2, Kannie W Y Chan1,2, Xiang Xu1, Nirbhay Yadav1,2, Guanshu Liu1,2, Peter C M van Zijl1,2.   

Abstract

PURPOSE: To develop an on-resonance variable delay multipulse (VDMP) scheme to image magnetization transfer contrast (MTC) and the chemical exchange saturation transfer (CEST) contrast of total fast-exchanging protons (TFP) with exchange rate above approximately 1 kHz.
METHODS: A train of high power binomial pulses was applied at the water resonance. The interpulse delay, called mixing time, was varied to observe its effect on the water signal reduction, allowing separation and quantification of MTC and CEST contributions as a result of their different proton transfer rates. The fast-exchanging protons in CEST and MTC are labeled together with the short T2 components in MTC and separated out using a variable mixing time.
RESULTS: Phantom studies of selected metabolite solutions (glucose, glutamate, creatine, myo-inositol), bovine serum albumin (BSA), and hair conditioner show the capability of on-resonance VDMP to separate out exchangeable protons with exchange rates above 1 kHz. Quantitative MTC and TFP maps were acquired on healthy mouse brains using this method, showing strong gray/white matter contrast for the slowly transferring MTC protons, whereas the TFP map was more uniform across the brain but somewhat higher in gray matter.
CONCLUSIONS: The new method provides a simple way of imaging fast-exchanging protons and MTC components with a slow transfer rate. Magn Reson Med 77:730-739, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  chemical exchange saturation transfer (CEST); magnetization transfer contrast (MTC); on-resonance VDMP; quantitative magnetization transfer (qMT); total fast-exchanging proton (TFP); variable delay multipulse (VDMP)

Mesh:

Substances:

Year:  2016        PMID: 26900759      PMCID: PMC5191984          DOI: 10.1002/mrm.26165

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  55 in total

1.  Optimum setting of binomial pulses for magnetization transfer contrast.

Authors:  N P Davies; I R Summers; W Vennart
Journal:  J Magn Reson Imaging       Date:  2000-05       Impact factor: 4.813

2.  Quantitative imaging of magnetization transfer using an inversion recovery sequence.

Authors:  Daniel F Gochberg; John C Gore
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

3.  Optimized MRI contrast for on-resonance proton exchange processes of PARACEST agents in biological systems.

Authors:  Alex X Li; Mojmir Suchy; Craig K Jones; Robert H E Hudson; Ravi S Menon; Robert Bartha
Journal:  Magn Reson Med       Date:  2009-11       Impact factor: 4.668

4.  Understanding quantitative pulsed CEST in the presence of MT.

Authors:  Kimberly L Desmond; Greg J Stanisz
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

5.  Magnetization transfer by simple sequences of rectangular pulses.

Authors:  J Forster; F Schick; M Pfeffer; O Lutz
Journal:  MAGMA       Date:  1995-07       Impact factor: 2.310

6.  In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T.

Authors:  Craig K Jones; Daniel Polders; Jun Hua; He Zhu; Hans J Hoogduin; Jinyuan Zhou; Peter Luijten; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2011-11-14       Impact factor: 4.668

7.  Cardio-chemical exchange saturation transfer magnetic resonance imaging reveals molecular signatures of endogenous fibrosis and exogenous contrast media.

Authors:  Moriel Vandsburger; Katrien Vandoorne; Roni Oren; Avigdor Leftin; Senzeni Mpofu; Daniela Delli Castelli; Silvio Aime; Michal Neeman
Journal:  Circ Cardiovasc Imaging       Date:  2014-12-30       Impact factor: 7.792

8.  Chemical exchange saturation transfer (CEST): what is in a name and what isn't?

Authors:  Peter C M van Zijl; Nirbhay N Yadav
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

9.  Natural D-glucose as a biodegradable MRI contrast agent for detecting cancer.

Authors:  Kannie W Y Chan; Michael T McMahon; Yoshinori Kato; Guanshu Liu; Jeff W M Bulte; Zaver M Bhujwalla; Dmitri Artemov; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2012-10-16       Impact factor: 4.668

10.  Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7T.

Authors:  Craig K Jones; Alan Huang; Jiadi Xu; Richard A E Edden; Michael Schär; Jun Hua; Nikita Oskolkov; Domenico Zacà; Jinyuan Zhou; Michael T McMahon; Jay J Pillai; Peter C M van Zijl
Journal:  Neuroimage       Date:  2013-04-06       Impact factor: 6.556

View more
  18 in total

1.  Dynamic glucose enhanced MRI of the placenta in a mouse model of intrauterine inflammation.

Authors:  Dan Wu; Jiadi Xu; Jun Lei; Michael Mclane; Peter C van Zijl; Irina Burd
Journal:  Placenta       Date:  2018-07-20       Impact factor: 3.481

2.  Separating fast and slow exchange transfer and magnetization transfer using off-resonance variable-delay multiple-pulse (VDMP) MRI.

Authors:  Lin Chen; Xiang Xu; Haifeng Zeng; Kannie W Y Chan; Nirbhay Yadav; Shuhui Cai; Kathryn J Schunke; Nauder Faraday; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2018-02-05       Impact factor: 4.668

3.  D-Glucose uptake and clearance in the tauopathy Alzheimer's disease mouse brain detected by on-resonance variable delay multiple pulse MRI.

Authors:  Lin Chen; Zhiliang Wei; Kannie Wy Chan; Yuguo Li; Kapil Suchal; Sheng Bi; Jianpan Huang; Xiang Xu; Philip C Wong; Hanzhang Lu; Peter Cm van Zijl; Tong Li; Jiadi Xu
Journal:  J Cereb Blood Flow Metab       Date:  2020-07-16       Impact factor: 6.200

Review 4.  CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

Authors:  Linda Knutsson; Jiadi Xu; André Ahlgren; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

5.  MRI detection of bacterial brain abscesses and monitoring of antibiotic treatment using bacCEST.

Authors:  Jing Liu; Renyuan Bai; Yuguo Li; Verena Staedtke; Shuixing Zhang; Peter C M van Zijl; Guanshu Liu
Journal:  Magn Reson Med       Date:  2018-03-25       Impact factor: 4.668

6.  Monitoring diffuse injury during disease progression in experimental autoimmune encephalomyelitis with on resonance variable delay multiple pulse (onVDMP) CEST MRI.

Authors:  Aline M Thomas; Jiadi Xu; Peter A Calabresi; Peter C M van Zijl; Jeff W M Bulte
Journal:  Neuroimage       Date:  2019-10-09       Impact factor: 6.556

7.  GlucoCEST imaging with on-resonance variable delay multiple pulse (onVDMP) MRI.

Authors:  Xiang Xu; Jiadi Xu; Kannie W Y Chan; Jing Liu; Huanling Liu; Yuguo Li; Lin Chen; Guanshu Liu; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

8.  The effect of the mTOR inhibitor rapamycin on glucoCEST signal in a preclinical model of glioblastoma.

Authors:  Xiang Xu; Jiadi Xu; Linda Knutsson; Jing Liu; Huanling Liu; Yuguo Li; Bachchu Lal; John Laterra; Dmitri Artemov; Guanshu Liu; Peter C M van Zijl; Kannie W Y Chan
Journal:  Magn Reson Med       Date:  2019-02-22       Impact factor: 4.668

9.  Evaluation of cell transplant-mediated attenuation of diffuse injury in experimental autoimmune encephalomyelitis using onVDMP CEST MRI.

Authors:  A M Thomas; S Li; C Chu; I Shats; J Xu; P A Calabresi; P C M van Zijl; P Walczak; J W M Bulte
Journal:  Exp Neurol       Date:  2020-04-15       Impact factor: 5.330

Review 10.  Magnetization Transfer Contrast and Chemical Exchange Saturation Transfer MRI. Features and analysis of the field-dependent saturation spectrum.

Authors:  Peter C M van Zijl; Wilfred W Lam; Jiadi Xu; Linda Knutsson; Greg J Stanisz
Journal:  Neuroimage       Date:  2017-04-21       Impact factor: 6.556

View more