Literature DB >> 21257894

Prospective gating with 320-MDCT angiography: effect of volume scan length on radiation dose.

Atif Khan1, Khurram Nasir, Faisal Khosa, Amina Saghir, Sheryar Sarwar, Melvin E Clouse.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the relation between radiation dose reduction and volume scan length for prospectively ECG-gated 320-MDCT angiography in the diagnosis of coronary artery disease.
MATERIALS AND METHODS: MDCT with prospective ECG gating was performed at one of the three volume scan lengths depending on heart length. Of 175 patients, 95 (55%; body mass index, 29 ± 5.9; mean heart rate, 59 ± 7 beats/min) underwent scanning at 160 mm; 46 (26%; body mass index, 30 ± 4.1; mean heart rate, 56 ± 5.74 beats/min) at 140 mm; and 34 (19%; body mass index, 30 ± 3.71; mean heart rate, 58 ± 3.96 beats/min) at 120 mm.
RESULTS: The median radiation doses were 6.5 mSv (95% CI, 6.03-7.2 mSv) for the 95 patients who underwent scanning at a volume scan length of 160 mm, 4.33 mSv (95% CI, 4.06-6.62 mSv) for the 46 patients who underwent scanning at 140 mm, and 3.47 mSv (95% CI, 3.15-3.62 mSv) for the 34 patients who underwent scanning at 120 mm. The reduction in scan length from 160 to 140 mm represented a reduction in scan length of 12.5% and the reduction to 120 mm a reduction of 25%. The median radiation dose was reduced 33% when volume scan length was changed to 140 mm and 47% when the length was changed to 120 mm.
CONCLUSION: Dose optimization remains an important concern in cardiac CT, and for 320-MDCT angiography, substantial dose reduction can be achieved by reducing volume scan length so that it is in concert with the patient's heart length.

Entities:  

Mesh:

Year:  2011        PMID: 21257894      PMCID: PMC3294289          DOI: 10.2214/AJR.10.4903

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  38 in total

1.  A new method to reduce radiation exposure during multi-row detector cardiac computed tomographic angiography.

Authors:  Ambarish Gopal; Matthew J Budoff
Journal:  Int J Cardiol       Date:  2007-12-18       Impact factor: 4.164

Review 2.  Recent developments in wide-detector cardiac computed tomography.

Authors:  Sang Il Choi; Richard T George; Karl H Schuleri; Eun Ju Chun; Joao A C Lima; Albert C Lardo
Journal:  Int J Cardiovasc Imaging       Date:  2009-03-03       Impact factor: 2.357

3.  64-Slice spiral computed tomography of the coronary arteries: dose reduction using an optimized imaging protocol including individual weight-adaptation of voltage and current-time product.

Authors:  Gunnar K Lund; Eckhard Wegian; Maythem Saeed; Jens Wassermeyer; Gerhard Adam; Alexander Stork
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

4.  Prospective and retrospective ECG gating for thoracic CT angiography: a comparative study.

Authors:  Wenhui Wu; Joseph Budovec; W Dennis Foley
Journal:  AJR Am J Roentgenol       Date:  2009-10       Impact factor: 3.959

5.  Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study.

Authors:  Gudrun M Feuchtner; Daniel Jodocy; Andrea Klauser; Bernhard Haberfellner; Iman Aglan; Alexander Spoeck; Stefan Hiehs; Peter Soegner; Werner Jaschke
Journal:  Eur J Radiol       Date:  2009-08-09       Impact factor: 3.528

6.  Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality.

Authors:  Tony DeFrance; Eric Dubois; Dan Gebow; Alex Ramirez; Florian Wolf; Gudrun M Feuchtner
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-07       Impact factor: 2.357

7.  Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation.

Authors:  Marc Dewey; Elke Zimmermann; Florian Deissenrieder; Michael Laule; Hans-Peter Dübel; Peter Schlattmann; Fabian Knebel; Wolfgang Rutsch; Bernd Hamm
Journal:  Circulation       Date:  2009-08-24       Impact factor: 29.690

8.  Impact of heart rate frequency and variability on radiation exposure, image quality, and diagnostic performance in dual-source spiral CT coronary angiography.

Authors:  Annick C Weustink; Lisanne A Neefjes; Stamatis Kyrzopoulos; Marcel van Straten; Rick Neoh Eu; Willem B Meijboom; Carlos A van Mieghem; Ermanno Capuano; Marcel L Dijkshoorn; Filippo Cademartiri; Eric Boersma; Pim J de Feyter; Gabriel P Krestin; Nico R Mollet
Journal:  Radiology       Date:  2009-10-28       Impact factor: 11.105

9.  Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques.

Authors:  Gilbert L Raff; Kavitha M Chinnaiyan; David A Share; Tauqir Y Goraya; Ella A Kazerooni; Mauro Moscucci; Ralph E Gentry; Aiden Abidov
Journal:  JAMA       Date:  2009-06-10       Impact factor: 56.272

10.  Reduced Z-axis coverage multidetector CT angiography for suspected acute pulmonary embolism could decrease dose and maintain diagnostic accuracy.

Authors:  Joshua A Kallen; Bret F Coughlin; Michael T O'Loughlin; Barry Stein
Journal:  Emerg Radiol       Date:  2009-05-26
View more
  9 in total

1.  Radiation dose of second-generation 320-detector row CT.

Authors:  Xue-jiang Qian
Journal:  Radiology       Date:  2013-09       Impact factor: 11.105

Review 2.  Established and emerging dose reduction methods in cardiac computed tomography.

Authors:  Gary R Small; Mustapha Kazmi; Robert A Dekemp; Benjamin J W Chow
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

3.  Effect of Tube Voltage (100 vs. 120 kVp) on Radiation Dose and Image Quality using Prospective Gating 320 Row Multi-detector Computed Tomography Angiography.

Authors:  Atif N Khan; Faisal Khosa; Waqas Shuaib; Khurram Nasir; Ron Blankstein; Melvin Clouse
Journal:  J Clin Imaging Sci       Date:  2013-12-31

Review 4.  State-of-the-art in CT hardware and scan modes for cardiovascular CT.

Authors:  Sandra Halliburton; Armin Arbab-Zadeh; Damini Dey; Andrew J Einstein; Ralph Gentry; Richard T George; Thomas Gerber; Mahadevappa Mahesh; Wm Guy Weigold
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-04-07

5.  Comparison of coronary plaque subtypes in male and female patients using 320-row MDCTA.

Authors:  Faisal Khosa; Atif N Khan; Khurram Nasir; Arash Bedayat; Zehra Malik; Ali F Jon; Ahmad R Cheema; Melvin E Clouse; Francine K Welty
Journal:  Atherosclerosis       Date:  2012-12-13       Impact factor: 5.162

6.  Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients.

Authors:  Marcus Y Chen; Sujata M Shanbhag; Andrew E Arai
Journal:  Radiology       Date:  2013-01-22       Impact factor: 11.105

7.  Assessment of coronary in-stent restenosis: value of subtraction coronary computed tomography angiography.

Authors:  Makoto Amanuma; Taskeshi Kondo; Tomonari Sano; Tomoya Takayanagi; Hideyuki Matsutani; Takako Sekine; Takehiro Arai; Hitomi Morita; Kazumasa Ishizaka; Kazumasa Arakita; Akiko Iwasa; Shinichi Takase
Journal:  Int J Cardiovasc Imaging       Date:  2015-12-12       Impact factor: 2.357

8.  Usefulness of dynamic volume scanning with 320-row CT in detecting recanalization of pulmonary arteriovenous fistula after coil embolization.

Authors:  Ryoichi Tanaka; Kunihiro Yoshioka; Masayuki Takeda; Kenta Muranaka; Miyuki Sone; Michiko Suzuki; Shigeru Ehara
Journal:  Springerplus       Date:  2013-04-17

9.  Absorbed radiation dose in radiosensitive organs using 64- and 320-row multidetector computed tomography: a comparative study.

Authors:  Atif N Khan; Waqas Shuaib; Boris Nikolic; Mohammad K Khan; Jian Kang; Faisal Khosa
Journal:  Scientifica (Cairo)       Date:  2014-08-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.