Literature DB >> 24605257

Effect of Tube Voltage (100 vs. 120 kVp) on Radiation Dose and Image Quality using Prospective Gating 320 Row Multi-detector Computed Tomography Angiography.

Atif N Khan1, Faisal Khosa2, Waqas Shuaib2, Khurram Nasir3, Ron Blankstein4, Melvin Clouse1.   

Abstract

OBJECTIVES: The objective of the following study is to evaluate the effect of reducing tube voltage from 120 to 100 kVp using prospective gating 320 row multi-detector computed tomography angiography on image quality and reduction in radiation dose.
MATERIALS AND METHODS: A total of 78 sequential patients were scanned with prospective electrocardiogram gating. A total of 45 patients (Group 1) with mean body mass index (BMI) 29 ± 2 and heart rate (HR) 57 ± 7 beats per minute (BPM) were scanned at 120 kVp. 33 patients (Group 2) with mean BMI 23 ± 3 and HR 58 ± 6 bpm were scanned at 100 kVp. Effective dose was calculated using dose length product and factor (k = 0.014). Quantitative assessment of image quality was calculated by measuring signal to noise ratio (SNR) and contrast to noise ratio (CNR) in the left ventricle and left main coronary artery. Two experienced cardiac radiologists using a three-point ordinal scale assessed subjectively image quality.
RESULTS: In Group 1, the median radiation dose was 5.31 mSv (95% confidence interval [CI]: 4.86-6.09) and for Group 2 (P = 0.009) the mean radiation dose was 3.71 mSv (95% CI: 2.76-4.87), representing 30% decrease in radiation dose. In multivariate analyses, adjusting for age, gender, HR, BMI, tube current and scan length, an absolute median reduction of 2.21 mSv (1.13-3.29 mSv) was noted in patients scanned with 100 kVp (P < 0.0001). The quantitative image quality (SNR and CNR) was not statistically significant between the groups. Subjective image quality was rated as good or excellent in 99% of coronary segments for both groups (P value was considered as non-significant).
CONCLUSION: Our study suggests that radiation dose may be lowered from 120 to 100 kVp with preservation of image quality in patient's whose BMI is ≤27.

Entities:  

Keywords:  Dose reduction; image quality; multi-detector computed tomography angiography; tube voltage

Year:  2013        PMID: 24605257      PMCID: PMC3935263          DOI: 10.4103/2156-7514.124092

Source DB:  PubMed          Journal:  J Clin Imaging Sci        ISSN: 2156-5597


  37 in total

1.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

2.  Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

Authors:  Andrew J Einstein; Carl D Elliston; Andrew E Arai; Marcus Y Chen; Richard Mather; Gregory D N Pearson; Robert L Delapaz; Edward Nickoloff; Ajoy Dutta; David J Brenner
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

3.  Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography.

Authors:  Stephan Achenbach; Tobias Goroll; Martin Seltmann; Tobias Pflederer; Katharina Anders; Dieter Ropers; Werner G Daniel; Michael Uder; Michael Lell; Mohamed Marwan
Journal:  JACC Cardiovasc Imaging       Date:  2011-04

4.  Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality.

Authors:  Bernhard A Herzog; Lars Husmann; Nina Burkhard; Ines Valenta; Oliver Gaemperli; Fuminari Tatsugami; Christophe A Wyss; Uif Landmesser; Philipp A Kaufmann
Journal:  Acad Radiol       Date:  2009-01       Impact factor: 3.173

Review 5.  History of cardiac computed tomography: single to 320-detector row multislice computed tomography.

Authors:  Gregory S Hurlock; Hiroshi Higashino; Teruhito Mochizuki
Journal:  Int J Cardiovasc Imaging       Date:  2009-01-15       Impact factor: 2.357

6.  Dose performance and image quality: dual source CT versus single source CT in cardiac CT angiography.

Authors:  Min Wang; Heng-Tao Qi; Xi-Ming Wang; Tao Wang; Jiu-Hong Chen; Cheng Liu
Journal:  Eur J Radiol       Date:  2008-10-02       Impact factor: 3.528

7.  Executive summary: heart disease and stroke statistics--2010 update: a report from the American Heart Association.

Authors:  Donald Lloyd-Jones; Robert J Adams; Todd M Brown; Mercedes Carnethon; Shifan Dai; Giovanni De Simone; T Bruce Ferguson; Earl Ford; Karen Furie; Cathleen Gillespie; Alan Go; Kurt Greenlund; Nancy Haase; Susan Hailpern; P Michael Ho; Virginia Howard; Brett Kissela; Steven Kittner; Daniel Lackland; Lynda Lisabeth; Ariane Marelli; Mary M McDermott; James Meigs; Dariush Mozaffarian; Michael Mussolino; Graham Nichol; Véronique L Roger; Wayne Rosamond; Ralph Sacco; Paul Sorlie; Randall Stafford; Thomas Thom; Sylvia Wasserthiel-Smoller; Nathan D Wong; Judith Wylie-Rosett
Journal:  Circulation       Date:  2010-02-23       Impact factor: 29.690

Review 8.  CT coronary angiography: 256-slice and 320-detector row scanners.

Authors:  Edward M Hsiao; Frank J Rybicki; Michael Steigner
Journal:  Curr Cardiol Rep       Date:  2010-01       Impact factor: 2.931

9.  The economic impact of ventriculoperitoneal shunt failure.

Authors:  Chevis N Shannon; Tamara D Simon; Gavin T Reed; Frank A Franklin; Russell S Kirby; Meredith L Kilgore; John C Wellons
Journal:  J Neurosurg Pediatr       Date:  2011-12       Impact factor: 2.375

10.  Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates.

Authors:  Jörg Hausleiter; Tanja Meyer; Martin Hadamitzky; Ester Huber; Maria Zankl; Stefan Martinoff; Adnan Kastrati; Albert Schömig
Journal:  Circulation       Date:  2006-03-06       Impact factor: 29.690

View more
  6 in total

Review 1.  Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose.

Authors:  Sock Keow Tan; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Kwan Hoong Ng; Yang Faridah Abdul Aziz; Kok Han Chee; Zhonghua Sun
Journal:  Br J Radiol       Date:  2018-03-29       Impact factor: 3.039

2.  Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening.

Authors:  Atif N Khan; Faisal Khosa; Boris Nikolic; Waqas Shuaib; Pei-Jan Paul Lin; Mohammad K Khan
Journal:  J Clin Imaging Sci       Date:  2014-04-29

3.  Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose.

Authors:  Philip V M Linsen; Adriaan Coenen; Marisa M Lubbers; Marcel L Dijkshoorn; Mohamed Ouhlous; Koen Nieman
Journal:  J Clin Imaging Sci       Date:  2016-10-21

4.  Evaluation of Ultra-Low-Dose Chest Computed Tomography Images in Detecting Lung Lesions Related to COVID-19: A Prospective Study.

Authors:  Fariba Zarei; Reza Jalli; Sabyasachi Chatterjee; Rezvan Ravanfar Haghighi; Pooya Iranpour; Vani Vardhan Chatterjee; Sedigheh Emadi
Journal:  Iran J Med Sci       Date:  2022-07

Review 5.  Vascular CT and MRI: a practical guide to imaging protocols.

Authors:  D J Murphy; A Aghayev; M L Steigner
Journal:  Insights Imaging       Date:  2018-03-14

6.  Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography.

Authors:  Seyedeh Shokoofeh Mousavi-Gazafroudi; Amirreza Sajjadieh-Khajouei; Maryam Moradi; Seyedeh Shabnam Mousavi-Gazafroudi; Ghasem Yadegarfar; Mohammad Bagher Tavakoli
Journal:  ARYA Atheroscler       Date:  2019-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.