Literature DB >> 21630110

Established and emerging dose reduction methods in cardiac computed tomography.

Gary R Small1, Mustapha Kazmi, Robert A Dekemp, Benjamin J W Chow.   

Abstract

Cardiac computed tomography (CT) is a non-invasive modality that is commonly used as an alternative to invasive coronary angiography for the investigation of coronary artery disease. The enthusiasm for this technology has been tempered by a growing appreciation of the potential risks of malignancy associated with the use of ionising radiation. In the spirit of minimizing patient risk, the medical profession and industry have worked hard to developed methods and protocols to reduce patient radiation exposure while maintaining excellent diagnostic accuracy. A complete understanding of radiation reduction techniques will allow clinicians to reduce patient risk while providing an important diagnostic service. This review will consider the established and emerging techniques that may be adopted to reduce patient absorbed doses from x-ray CT. By modifying (1) x-ray tube output, (2) imaging time (scan duration), (3) imaging distance (scan length) and (4) the appropriate use of shielding, clinicians will be able to adhere to the 'as low as reasonably achievable (ALARA)' principle.

Entities:  

Mesh:

Year:  2011        PMID: 21630110     DOI: 10.1007/s12350-011-9400-1

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  46 in total

Review 1.  Multislice CT angiography in cardiac imaging. Part III: radiation risk and dose reduction.

Authors:  Z Sun; K H Ng
Journal:  Singapore Med J       Date:  2010-05       Impact factor: 1.858

2.  Whole-heart 320-row computed tomography: reduction of radiation dose via prior coronary calcium scanning.

Authors:  E Zimmermann; M Dewey
Journal:  Rofo       Date:  2010-08-19

3.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation.

Authors:  Tom H Mulkens; Patrick Bellinck; Michel Baeyaert; Dirk Ghysen; Xavier Van Dijck; Elvier Mussen; Caroline Venstermans; Jean-Luc Termote
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

5.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

Review 6.  Physics of cardiac imaging with multiple-row detector CT.

Authors:  Mahadevappa Mahesh; Dianna D Cody
Journal:  Radiographics       Date:  2007 Sep-Oct       Impact factor: 5.333

7.  Effect of padding duration on radiation dose and image interpretation in prospectively ECG-triggered coronary CT angiography.

Authors:  Troy M Labounty; Jonathon Leipsic; James K Min; Brett Heilbron; G B John Mancini; Fay Y Lin; James P Earls
Journal:  AJR Am J Roentgenol       Date:  2010-04       Impact factor: 3.959

Review 8.  Radiation safety considerations for diagnostic radiology personnel.

Authors:  L Brateman
Journal:  Radiographics       Date:  1999 Jul-Aug       Impact factor: 5.333

Review 9.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

10.  Radiation dose in a "triple rule-out" coronary CT angiography protocol of emergency department patients using 64-MDCT: the impact of ECG-based tube current modulation on age, sex, and body mass index.

Authors:  Kevin M Takakuwa; Ethan J Halpern; Eric L Gingold; David C Levin; Frances S Shofer
Journal:  AJR Am J Roentgenol       Date:  2009-04       Impact factor: 3.959

View more
  6 in total

Review 1.  Stress CT perfusion: coupling coronary anatomy with physiology.

Authors:  Edward A Hulten; Marcio Sommer Bittencourt; Brian Ghoshhajra; Ron Blankstein
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

Review 2.  Left main coronary artery disease: A review of the spectrum of noninvasive diagnostic modalities.

Authors:  Nishtha Sareen; Karthik Ananthasubramaniam
Journal:  J Nucl Cardiol       Date:  2015-10-20       Impact factor: 5.952

3.  Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography.

Authors:  Linnea Hornbech Larsen; Klaus Fuglsang Kofoed; Helle Gervig Carstensen; Mads Rams Mejdahl; Mads Jønsson Andersen; Jesper Kjaergaard; Olav Wendelboe Nielsen; Lars Køber; Rasmus Møgelvang; Christian Hassager
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-15       Impact factor: 2.357

4.  Radiation risk from cardiac CT and nuclear cardiology: addressing concerns with innovative solutions.

Authors:  Andrew J Einstein
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

5.  Image noise-based dose adaptation in dynamic volume CT of the heart: dose and image quality optimisation in comparison with BMI-based dose adaptation.

Authors:  Devang Odedra; Joerg Blobel; Saad Alhumayyd; Miranda Durand; Laura Jimenez-Juan; Narinder Paul
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

Review 6.  Coronary CT Angiography Guided Medical Therapy in Subclinical Atherosclerosis.

Authors:  Alyssa L S Chow; Saad D Alhassani; Andrew M Crean; Gary R Small
Journal:  J Clin Med       Date:  2021-02-07       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.