Literature DB >> 19468764

Reduced Z-axis coverage multidetector CT angiography for suspected acute pulmonary embolism could decrease dose and maintain diagnostic accuracy.

Joshua A Kallen1, Bret F Coughlin, Michael T O'Loughlin, Barry Stein.   

Abstract

Multidetector computed tomographic angiography (MDCTA) is the method of choice for evaluation of suspected acute pulmonary embolism (PE) in most patients because it is accurate and widely available. The use of computed tomography, including MDCTA for PE, has risen dramatically over the last several years with an attendant rise in radiation exposure. Many methods currently employed to reduce radiation dose may affect image quality and potentially affect diagnostic accuracy. Reducing Z-axis coverage would decrease radiation dose without any effect on image quality. This study was performed to assess the effect on the accuracy of MDCTA for suspected acute PE if the Z-axis coverage was reduced to the anatomic range from the top of the aortic arch through the heart. Two hundred ninety-five examinations were performed on a 64-detector-row MDCT and interpreted as positive for PE from July 2005 to February 2008. When the anatomic range of these data sets were retrospectively reduced and reinterpreted for PE, no case was interpreted as negative for PE. The Z-axis coverage was reduced by 37%. In the interest of keeping radiation doses as low as reasonably achievable, further research in this area is warranted.

Entities:  

Mesh:

Year:  2009        PMID: 19468764     DOI: 10.1007/s10140-009-0818-6

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  22 in total

1.  Oral anticoagulation and risk of death: a medical record linkage study.

Authors:  Anders Odén; Martin Fahlén
Journal:  BMJ       Date:  2002-11-09

2.  Diagnostic pathways in acute pulmonary embolism: recommendations of the PIOPED II Investigators.

Authors:  Paul D Stein; Pamela K Woodard; John G Weg; Thomas W Wakefield; Victor F Tapson; H Dirk Sostman; Thomas A Sos; Deborah A Quinn; Kenneth V Leeper; Russell D Hull; Charles A Hales; Alexander Gottschalk; Lawrence R Goodman; Sarah E Fowler; John D Buckley
Journal:  Radiology       Date:  2007-01       Impact factor: 11.105

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Reduced-dose CT: effect on reader evaluation in detection of pulmonary embolism.

Authors:  John D MacKenzie; Javier Nazario-Larrieu; Tianxi Cai; M Stephen Ledbetter; Maria Alejandra Duran-Mendicuti; Philip F Judy; Frank J Rybicki
Journal:  AJR Am J Roentgenol       Date:  2007-12       Impact factor: 3.959

Review 5.  Radiation dose reduction in chest CT: a review.

Authors:  Takeshi Kubo; Pei-Jan Paul Lin; Wolfram Stiller; Masaya Takahashi; Hans-Ulrich Kauczor; Yoshiharu Ohno; Hiroto Hatabu
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

Review 6.  Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society.

Authors:  Martine Remy-Jardin; Massimo Pistolesi; Lawrence R Goodman; Warren B Gefter; Alexander Gottschalk; John R Mayo; H Dirk Sostman
Journal:  Radiology       Date:  2007-09-11       Impact factor: 11.105

7.  The effect of single-detector CT versus MDCT on clinical outcomes in patients with suspected acute pulmonary embolism and negative results on CT pulmonary angiography.

Authors:  John David Prologo; Robert C Gilkeson; Mireya Diaz; Matthew Cummings
Journal:  AJR Am J Roentgenol       Date:  2005-04       Impact factor: 3.959

8.  CT pulmonary angiography: a comparative analysis of the utilization patterns in emergency department and hospitalized patients between 1998 and 2003.

Authors:  J David Prologo; Robert C Gilkeson; Mireya Diaz; Joe Asaad
Journal:  AJR Am J Roentgenol       Date:  2004-10       Impact factor: 3.959

9.  Utilization patterns and diagnostic yield of 3421 consecutive multidetector row computed tomography pulmonary angiograms in a busy emergency department.

Authors:  Jay H Donohoo; William W Mayo-Smith; John A Pezzullo; Thomas K Egglin
Journal:  J Comput Assist Tomogr       Date:  2008 May-Jun       Impact factor: 1.826

10.  Evaluation of a "triple rule-out" coronary CT angiography protocol: use of 64-Section CT in low-to-moderate risk emergency department patients suspected of having acute coronary syndrome.

Authors:  Kevin M Takakuwa; Ethan J Halpern
Journal:  Radiology       Date:  2008-08       Impact factor: 11.105

View more
  13 in total

1.  Dose of reduced z-axis length of computed tomography angiography (CTA) of the chest for pulmonary embolism using 64-detector rows and adaptive iterative reconstruction techniques.

Authors:  Jared Martillotti; Naomi Silva; Jyoti Chhabra; Christian Molstrom; Ryan Coughlin; Michael O'Loughlin; Bret Coughlin
Journal:  Emerg Radiol       Date:  2012-08-17

Review 2.  State of the art: technologies for computed tomography dose reduction.

Authors:  Martin L D Gunn; Jennifer R Kohr
Journal:  Emerg Radiol       Date:  2009-11-20

3.  Quantification of radiation dose reduction by reducing z-axis coverage in 320-detector coronary CT angiography.

Authors:  David J Murphy; Abhishek Keraliya; Nathan Himes; Ayaz Aghayev; Ron Blankstein; Michael L Steigner
Journal:  Br J Radiol       Date:  2017-06-14       Impact factor: 3.039

4.  Chest multidetector computed tomography (MDCT) in patients with suspected acute pulmonary embolism: diagnostic yield and proportion of other clinically relevant findings.

Authors:  L Cereser; D Bagatto; R Girometti; G Como; C Zuiani; M Bazzocchi
Journal:  Radiol Med       Date:  2010-12-03       Impact factor: 3.469

5.  Reduced z-axis coverage in multidetector-row CT pulmonary angiography decreases radiation dose and diagnostic accuracy of alternative diseases.

Authors:  N Michalakis; C Keyzer; V De Maertelaer; D Tack; P A Gevenois
Journal:  Br J Radiol       Date:  2013-11-20       Impact factor: 3.039

6.  Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial.

Authors:  Xavier Montet; Anne-Lise Hachulla; Angeliki Neroladaki; Frederic Lador; Thierry Rochat; Diomidis Botsikas; Christoph D Becker
Journal:  Eur Radiol       Date:  2014-12-21       Impact factor: 5.315

7.  Prospective gating with 320-MDCT angiography: effect of volume scan length on radiation dose.

Authors:  Atif Khan; Khurram Nasir; Faisal Khosa; Amina Saghir; Sheryar Sarwar; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2011-02       Impact factor: 3.959

8.  Clinical CT underestimation of the percentage volume occupied by cysts in patients with lymphangioleiomyomatosis.

Authors:  Thomas C Larsen; Amir M Hasani; Shirley F Rollison; Tania R Machado; Amanda M Jones; Patricia Julien-Williams; Marcus Y Chen; Joel Moss; Han Wen
Journal:  Clin Imaging       Date:  2019-11-27       Impact factor: 1.605

9.  Reduced z-axis technique for CT Pulmonary angiography in pregnancy--validation for practical use and dose reduction.

Authors:  Kaushik Shahir; Jonathan M McCrea; Luis Antonio Sosa Lozano; Lawrence R Goodman
Journal:  Emerg Radiol       Date:  2015-08-25

10.  Effect of reduced z-axis scan coverage on diagnostic performance and radiation dose of neck computed tomography in patients with suspected cervical abscess.

Authors:  Jakob Weiss; Michael Maurer; Dominik Ketelsen; Mike Notohamiprodjo; Dominik Zinsser; Julian L Wichmann; Konstantin Nikolaou; Fabian Bamberg; Ahmed E Othman
Journal:  PLoS One       Date:  2017-07-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.