Literature DB >> 26662268

Assessment of coronary in-stent restenosis: value of subtraction coronary computed tomography angiography.

Makoto Amanuma1, Taskeshi Kondo2, Tomonari Sano3, Tomoya Takayanagi3, Hideyuki Matsutani3, Takako Sekine3, Takehiro Arai3, Hitomi Morita3, Kazumasa Ishizaka3, Kazumasa Arakita4, Akiko Iwasa5, Shinichi Takase6.   

Abstract

In conventional coronary computed tomography angiography (CCTA), metal artifacts are frequently observed where stents are located, making it difficult to evaluate in-stent restenosis. This study was conducted to investigate whether subtraction CCTA can improve diagnostic accuracy in the evaluation of in-stent restenosis. Subtraction CCTA was performed using 320-row CT in 398 patients with previously placed stents who were able to hold their breath for 25 s and in whom mid-diastolic prospective one-beat scanning was possible. Among these patients, 126 patients (94 men and 32 women, age 74 ± 8 years) with 370 stents who also underwent invasive coronary angiography (ICA) were selected as the subjects of this study. With ICA findings considered the gold standard, conventional CCTA was compared against subtraction CCTA to determine whether subtraction can improve diagnostic accuracy in the evaluation of in-stent restenosis. When non-assessable stents were considered to be stenotic, the diagnostic accuracy in the evaluation of in-stent restenosis was 62.7 % for conventional CCTA and 89.5 % for subtraction CCTA. When the non-assessable stents were considered to be non-stenotic the diagnostic accuracy was 90.3 % for conventional CCTA and 94.31 % for subtraction CCTA. When subtraction CCTA was used to evaluate only the 138 stents that were judged to be non-assessable by conventional CCTA, 116 of these stents were judged to be assessable, and the findings for 109 of them agreed with those obtained by ICA. Even for stents with an internal diameter of 2.5-3 mm, the lumen can be evaluated in more than 80 % of patients. Subtraction CCTA provides significantly higher diagnostic accuracy than conventional CCTA in the evaluation of in-stent restenosis.

Entities:  

Keywords:  Computed tomography; Coronary CTA; In-stent restenosis; Metallic stent; Subtraction

Mesh:

Year:  2015        PMID: 26662268     DOI: 10.1007/s10554-015-0826-4

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  28 in total

1.  CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study.

Authors:  H W Venema; F J Hulsmans; G J den Heeten
Journal:  Radiology       Date:  2001-03       Impact factor: 11.105

2.  Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms.

Authors:  Zhuren Luo; Dan Wang; Xilin Sun; Tong Zhang; Fang Liu; Dandan Dong; Nicholas K Chan; Baozhong Shen
Journal:  Eur J Radiol       Date:  2011-05-31       Impact factor: 3.528

3.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

4.  Subtraction coronary CT angiography using second-generation 320-detector row CT.

Authors:  Kunihiro Yoshioka; Ryoichi Tanaka; Kenta Muranaka; Tadashi Sasaki; Takanori Ueda; Takuya Chiba; Kouta Takeda; Tsuyoshi Sugawara
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-27       Impact factor: 2.357

5.  Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

Authors:  Andrew J Einstein; Carl D Elliston; Andrew E Arai; Marcus Y Chen; Richard Mather; Gregory D N Pearson; Robert L Delapaz; Edward Nickoloff; Ajoy Dutta; David J Brenner
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

6.  Novel method of displaying coronary CT angiography: Angiographic view.

Authors:  Masahiro Jinzaki; Kozo Sato; Yutaka Tanami; Minoru Yamada; Sachio Kuribayashi; Toshihisa Anzai; Yasushi Asakura; Satoshi Ogawa
Journal:  Circ J       Date:  2006-12       Impact factor: 2.993

7.  Coronary stent patency: dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom.

Authors:  Daniel T Boll; Elmar M Merkle; Erik K Paulson; Thorsten R Fleiter
Journal:  Radiology       Date:  2008-04-18       Impact factor: 11.105

Review 8.  Current and Novel Imaging Techniques in Coronary CT.

Authors:  Haruhiko Machida; Isao Tanaka; Rika Fukui; Yun Shen; Takuya Ishikawa; Etsuko Tate; Eiko Ueno
Journal:  Radiographics       Date:  2015-06-05       Impact factor: 5.333

9.  Serial coronary CT angiography-verified changes in plaque characteristics as an end point: evaluation of effect of statin intervention.

Authors:  Kaori Inoue; Sadako Motoyama; Masayoshi Sarai; Takahisa Sato; Hiroto Harigaya; Tomonori Hara; Yoshihiro Sanda; Hirofumi Anno; Takeshi Kondo; Nathan D Wong; Jagat Narula; Yukio Ozaki
Journal:  JACC Cardiovasc Imaging       Date:  2010-07

10.  Image quality and radiation dose stratified by patient heart rate for coronary 64- and 320-MDCT angiography.

Authors:  Shinichiro Fujimoto; Hideyuki Matsutani; Takeshi Kondo; Tomonari Sano; Kanako Kumamaru; Shinichi Takase; Frank J Rybicki
Journal:  AJR Am J Roentgenol       Date:  2013-04       Impact factor: 3.959

View more
  8 in total

1.  Initial exploration of coronary stent image subtraction using dual-layer spectral CT.

Authors:  Le Qin; ShengJia Gu; ChiHua Chen; Huan Zhang; ZhenBin Zhu; XingBiao Chen; Qun Han; FuHua Yan; WenJie Yang
Journal:  Eur Radiol       Date:  2019-01-21       Impact factor: 5.315

Review 2.  Cardiovascular imaging 2015 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2016-05       Impact factor: 2.357

3.  Diagnostic accuracy of a modified subtraction coronary CT angiography method with short breath-holding time: a feasibility study.

Authors:  Kunihiro Yoshioka; Ryoichi Tanaka; Hidenobu Takagi; Kyouhei Nagata; Takuya Chiba; Kouta Takeda; Takanori Ueda; Tsuyoshi Sugawara; Akinobu Sasaki; Yuta Ueyama; Kei Kikuchi; Tadashi Sasaki
Journal:  Br J Radiol       Date:  2016-08-15       Impact factor: 3.039

4.  Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents-the C-Sub 320 multicenter trial.

Authors:  Andreas Fuchs; J Tobias Kühl; Marcus Y Chen; David Viladés Medel; Xavier Alomar; Sujata M Shanbhag; Steffen Helqvist; Klaus F Kofoed
Journal:  Eur Radiol       Date:  2018-04-25       Impact factor: 5.315

5.  Cardiovascular imaging 2016 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Vande Veire
Journal:  Int J Cardiovasc Imaging       Date:  2017-06       Impact factor: 2.357

6.  Modified Subtraction Coronary CT Angiography with a Two-Breathhold Technique: Image Quality and Diagnostic Accuracy in Patients with Coronary Calcifications.

Authors:  Weifeng Guo; Pratik Tripathi; Shan Yang; Juying Qian; Bimal Rai; Mengsu Zeng
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

7.  Inter-observer agreement of the Coronary Artery Disease Reporting and Data System (CAD-RADSTM) in patients with stable chest pain.

Authors:  Ahmed Abdel Khalek Abdel Razek; Mohamed Magdy Elrakhawy; Mahmoud Mohamed Yossof; Hadeer Mohamed Nageb
Journal:  Pol J Radiol       Date:  2018-04-16

8.  The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT.

Authors:  Jian Li; Man-Tao Guo; Xiao Yang; Fang Gao; Na Li; Ming-Gang Huang
Journal:  Medicine (Baltimore)       Date:  2021-12-23       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.