Literature DB >> 19897497

Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition.

Stephan Achenbach1, Mohamed Marwan, Dieter Ropers, Tiziano Schepis, Tobias Pflederer, Katharina Anders, Axel Kuettner, Werner G Daniel, Michael Uder, Michael M Lell.   

Abstract

AIMS: We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. METHODS AND
RESULTS: In 50 consecutive patients (body weight <or= 100 kg, sinus rhythm <or=60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'.
CONCLUSION: In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19897497     DOI: 10.1093/eurheartj/ehp470

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  170 in total

1.  Prognostic value of CT coronary angiography: focus on obstructive vs. nonobstructive disease and on the presence of left main disease.

Authors:  E Maffei; S Seitun; C Martini; A Aldrovandi; T Arcadi; A Clemente; G Messalli; R Malagò; A Weustink; N Mollet; K Nieman; D Ardissino; P de Feyter; G Krestin; F Cademartiri
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

2.  Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography.

Authors:  Satoshi Okayama; Ayako Seno; Tsunenari Soeda; Yasuhiro Takami; Rika Kawakami; Satoshi Somekawa; Ken-Ichi Ishigami; Yukiji Takeda; Hiroyuki Kawata; Manabu Horii; Shiro Uemura; Yoshihiko Saito
Journal:  Int J Cardiovasc Imaging       Date:  2011-06-03       Impact factor: 2.357

Review 3.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 4.  Understanding the genetics of coronary artery disease through the lens of noninvasive imaging.

Authors:  Eunice Yang; Jose D Vargas; David A Bluemke
Journal:  Expert Rev Cardiovasc Ther       Date:  2012-01

Review 5.  Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis.

Authors:  Zhonghua Sun; Kwan-Hoong Ng
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-04       Impact factor: 2.357

Review 6.  Low-dose cardiovascular computed tomography: where are the limits?

Authors:  Paul Schoenhagen; Carla M Thompson; Sandra S Halliburton
Journal:  Curr Cardiol Rep       Date:  2012-02       Impact factor: 2.931

7.  DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study.

Authors:  Dominik Geisel; Elke Zimmermann; Matthias Rief; Johannes Greupner; Michael Laule; Fabian Knebel; Bernd Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2012-04-17       Impact factor: 5.315

Review 8.  Coronary CT angiography with prospective ECG-triggering: an effective alternative to invasive coronary angiography.

Authors:  Zhonghua Sun
Journal:  Cardiovasc Diagn Ther       Date:  2012-03

9.  Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography.

Authors:  Long Jiang Zhang; Yining Wang; U Joseph Schoepf; Felix G Meinel; Richard R Bayer; Li Qi; Jian Cao; Chang Sheng Zhou; Yan E Zhao; Xie Li; Jian Bin Gong; Zhengyu Jin; Guang Ming Lu
Journal:  Eur Radiol       Date:  2015-09-17       Impact factor: 5.315

10.  Blooming Artifact Reduction in Coronary Artery Calcification by A New De-blooming Algorithm: Initial Study.

Authors:  Ping Li; Lei Xu; Lin Yang; Rui Wang; Jiang Hsieh; Zhonghua Sun; Zhanming Fan; Jonathon A Leipsic
Journal:  Sci Rep       Date:  2018-05-02       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.