Literature DB >> 22187198

Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose.

Eun-Ah Park1, Whal Lee, Kwang Woo Kim, Kwang Gi Kim, Allmendinger Thomas, Jin Wook Chung, Jae Hyung Park.   

Abstract

To assess the image quality and radiation dose of low-dose dual-source CT (DSCT) coronary angiography reconstructed using iterative reconstruction in image space (IRIS), in comparison with routine-dose CT using filtered back projection (FBP). Eighty-one patients underwent low-dose coronary DSCT using IRIS with two protocols: (a)100 kVp and 200 mAs per rotation for body mass index (BMI) < 25 (group I), (b)100 kVp and 320 mAs for BMI ≥ 25 (II). For comparison, two sex-and BMI-matched groups using standard protocols with FBP were selected: (a)100 kVp and 320 mAs for BMI < 25 (III), (b)120 kVp and 320 mAs for BMI ≥ 25 (IV). Image noise, signal to noise ratio (SNR) and modulation transfer function (MTF) 50% were objectively calculated. Two blinded readers then subjectively graded the image quality. Radiation dose was also measured. Image noise tended to be lower in IRIS of low-dose protocols: 22.0 ± 4.5 for group I versus 24.8 ± 4.0 for III (P < 0.001); 20.9 ± 4.5 for II versus 21.6 ± 4.9 for IV (P = 0.6). SNR was better with IRIS: 25.8 ± 4.4 for I versus 22.7 ± 4.6 for III (P < 0.001); 24.6 ± 5.4 for II versus 18.7 ± 4.5 for IV (P < 0.001). No differences in MTF 50% or image quality scores were seen between each two groups (P > 0.05). Radiation reduction was 40% for I and 51% for II, compared to standard protocols. Compared with routine-dose CT using FBP, low-dose coronary angiography using IRIS provides significant radiation reduction without impairment to image quality.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22187198     DOI: 10.1007/s10554-011-0004-2

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  35 in total

1.  Adaptive statistical iterative reconstruction technique for pulmonary CT: image quality of the cadaveric lung on standard- and reduced-dose CT.

Authors:  Masahiro Yanagawa; Osamu Honda; Shigeyuki Yoshida; Ayano Kikuyama; Atsuo Inoue; Hiromitsu Sumikawa; Mitsuhiro Koyama; Noriyuki Tomiyama
Journal:  Acad Radiol       Date:  2010-07-15       Impact factor: 3.173

2.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Jeanne B Ackman; Subba R Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O Shepard; Matthew D Gilman
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

4.  Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT.

Authors:  Wieland H Sommer; Edda Albrecht; Fabian Bamberg; Jan C Schenzle; Thorsten R Johnson; Klement Neumaier; Maximilian F Reiser; Konstatin Nikolaou
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

Review 5.  Computed tomography--old ideas and new technology.

Authors:  Dominik Fleischmann; F Edward Boas
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

6.  Iterative image reconstruction techniques: Applications for cardiac CT.

Authors:  Matthias Renker; Ashok Ramachandra; U Joseph Schoepf; Rainer Raupach; Paul Apfaltrer; Garrett W Rowe; Sebastian Vogt; Thomas G Flohr; J Matthias Kerl; Ralf W Bauer; Christian Fink; Thomas Henzler
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-05-25

7.  Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

Authors:  Márcio Sommer Bittencourt; Bernhard Schmidt; Martin Seltmann; Gerd Muschiol; Dieter Ropers; Werner Günther Daniel; Stephan Achenbach
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-01       Impact factor: 2.357

8.  Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study.

Authors:  Kristina T Flicek; Amy K Hara; Alvin C Silva; Qing Wu; Mary B Peter; C Daniel Johnson
Journal:  AJR Am J Roentgenol       Date:  2010-07       Impact factor: 3.959

9.  Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates.

Authors:  Jörg Hausleiter; Tanja Meyer; Martin Hadamitzky; Ester Huber; Maria Zankl; Stefan Martinoff; Adnan Kastrati; Albert Schömig
Journal:  Circulation       Date:  2006-03-06       Impact factor: 29.690

Review 10.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

View more
  16 in total

1.  Image quality of adaptive iterative dose reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection.

Authors:  Roh-Eul Yoo; Eun-Ah Park; Whal Lee; Hackjoon Shim; Yeo Koon Kim; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-26       Impact factor: 2.357

2.  Iterative reconstruction improves evaluation of native aortic and mitral valves by retrospectively ECG-gated thoracoabdominal CTA.

Authors:  Martin J Willemink; Jesse Habets; Pim A de Jong; Arnold M R Schilham; Willem P Th M Mali; Tim Leiner; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2012-10-13       Impact factor: 5.315

3.  Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality.

Authors:  Martin J Willemink; Tim Leiner; Pim A de Jong; Linda M de Heer; Rutger A J Nievelstein; Arnold M R Schilham; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

4.  Iterative reconstruction techniques for computed tomography Part 1: technical principles.

Authors:  Martin J Willemink; Pim A de Jong; Tim Leiner; Linda M de Heer; Rutger A J Nievelstein; Ricardo P J Budde; Arnold M R Schilham
Journal:  Eur Radiol       Date:  2013-01-12       Impact factor: 5.315

Review 5.  Cardiovascular imaging 2012 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2013-04       Impact factor: 2.357

6.  320-row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC): effect of 100 kV versus 120 kV on image quality and dose exposure.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Marco Perri; Alessandra Splendiani; Giovanni Luca Gravina; Antonio Barile; Carlo Masciocchi
Journal:  Radiol Med       Date:  2016-05-12       Impact factor: 3.469

7.  Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease.

Authors:  Yang Hou; Yue Ma; Weipeng Fan; Yuke Wang; Mei Yu; Mani Vembar; Qiyong Guo
Journal:  Eur Radiol       Date:  2013-07-26       Impact factor: 5.315

8.  Assessment of dose exposure and image quality in coronary angiography performed by 640-slice CT: a comparison between adaptive iterative and filtered back-projection algorithm by propensity analysis.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Alessandra Splendiani; Giovanni Luca Gravina; Antonio Barile; Carlo Masciocchi
Journal:  Radiol Med       Date:  2014-02-20       Impact factor: 3.469

9.  Optimizing radiation dose levels in prospectively electrocardiogram-triggered coronary computed tomography angiography using iterative reconstruction techniques: a phantom and patient study.

Authors:  Yang Hou; Jiahe Zheng; Yuke Wang; Mei Yu; Mani Vembar; Qiyong Guo
Journal:  PLoS One       Date:  2013-02-20       Impact factor: 3.240

10.  Impact of sinogram affirmed iterative reconstruction (SAFIRE) algorithm on image quality with 70 kVp-tube-voltage dual-source CT angiography in children with congenital heart disease.

Authors:  Pei Nie; Haiou Li; Yanhua Duan; Ximing Wang; Xiaopeng Ji; Zhaoping Cheng; Anbiao Wang; Jiuhong Chen
Journal:  PLoS One       Date:  2014-03-10       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.