BACKGROUND: Coronary computed tomographic angiography (CCTA) is associated with high radiation dose to the female breasts. Bismuth breast shielding offers the potential to significantly reduce dose to the breasts and nearby organs, but the magnitude of this reduction and its impact on image quality and radiation dose have not been evaluated. METHODS: Radiation doses from CCTA to critical organs were determined using metal-oxide-semiconductor field-effect transistors positioned in a customized anthropomorphic whole-body dosimetry verification phantom. Image noise and signal were measured in regions of interest (ROIs) including the coronary arteries. RESULTS: With bismuth shielding, breast radiation dose was reduced 46%-57% depending on breast size and scanning technique, with more moderate dose reduction to the heart, lungs, and esophagus. However, shielding significantly decreased image signal (by 14.6 HU) and contrast (by 28.4 HU), modestly but significantly increased image noise in ROIs in locations of coronary arteries, and decreased contrast-to-noise ratio by 20.9%. CONCLUSIONS: While bismuth breast shielding can significantly decrease radiation dose to critical organs, it is associated with an increase in image noise, decrease in contrast-to-noise, and changes tissue attenuation characteristics in the location of the coronary arteries.
BACKGROUND: Coronary computed tomographic angiography (CCTA) is associated with high radiation dose to the female breasts. Bismuth breast shielding offers the potential to significantly reduce dose to the breasts and nearby organs, but the magnitude of this reduction and its impact on image quality and radiation dose have not been evaluated. METHODS: Radiation doses from CCTA to critical organs were determined using metal-oxide-semiconductor field-effect transistors positioned in a customized anthropomorphic whole-body dosimetry verification phantom. Image noise and signal were measured in regions of interest (ROIs) including the coronary arteries. RESULTS: With bismuth shielding, breast radiation dose was reduced 46%-57% depending on breast size and scanning technique, with more moderate dose reduction to the heart, lungs, and esophagus. However, shielding significantly decreased image signal (by 14.6 HU) and contrast (by 28.4 HU), modestly but significantly increased image noise in ROIs in locations of coronary arteries, and decreased contrast-to-noise ratio by 20.9%. CONCLUSIONS: While bismuth breast shielding can significantly decrease radiation dose to critical organs, it is associated with an increase in image noise, decrease in contrast-to-noise, and changes tissue attenuation characteristics in the location of the coronary arteries.
Authors: Courtney Coursey; Donald P Frush; Terry Yoshizumi; Greta Toncheva; Giao Nguyen; S Bruce Greenberg Journal: AJR Am J Roentgenol Date: 2008-01 Impact factor: 3.959
Authors: Lynne M Hurwitz; Terry T Yoshizumi; Philip C Goodman; Rendon C Nelson; Greta Toncheva; Giao B Nguyen; Carolyn Lowry; Colin Anderson-Evans Journal: AJR Am J Roentgenol Date: 2009-01 Impact factor: 3.959
Authors: W Bob Meijboom; Matthijs F L Meijs; Joanne D Schuijf; Maarten J Cramer; Nico R Mollet; Carlos A G van Mieghem; Koen Nieman; Jacob M van Werkhoven; Gabija Pundziute; Annick C Weustink; Alexander M de Vos; Francesca Pugliese; Benno Rensing; J Wouter Jukema; Jeroen J Bax; Mathias Prokop; Pieter A Doevendans; Myriam G M Hunink; Gabriel P Krestin; Pim J de Feyter Journal: J Am Coll Cardiol Date: 2008-12-16 Impact factor: 24.094
Authors: Matthew J Budoff; David Dowe; James G Jollis; Michael Gitter; John Sutherland; Edward Halamert; Markus Scherer; Raye Bellinger; Arthur Martin; Robert Benton; Augustin Delago; James K Min Journal: J Am Coll Cardiol Date: 2008-11-18 Impact factor: 24.094
Authors: Sigal Trattner; Bin Cheng; Radoslaw L Pieniazek; Udo Hoffmann; Pamela S Douglas; Andrew J Einstein Journal: Med Phys Date: 2014-04 Impact factor: 4.071