Literature DB >> 26535552

Realistic Simulation of Regional Myocardial Perfusion Defects for Cardiac SPECT Studies.

George S K Fung1, W Paul Segars2, Taek-Soo Lee1, Takahiro Higuchi1, Alexander I Veress3, Grant T Gullberg4, Benjamin M W Tsui1.   

Abstract

The current 3D XCAT phantom allows users to manually define the regional myocardial perfusion defect (MPD) as a simple pie-shaped wedge region with reduced activity level in the myocardium of left ventricle. To more accurately and realistically model the MPD, we have developed a new regional MPD model for the 3D XCAT phantom for myocardial perfusion SPECT (MP-SPECT) studies based on the location and the severity of the stenosis in a computer generated coronary arterial tree. First, we generated a detailed coronary arterial tree by extending the large proximal branches segmented from patient CT images to cover the whole heart using an iterative rule-based algorithm. Second, we determined the affected downstream vascular segments of a given stenosis. Third, we computed the activity of each myocardial region as a function of the inverse-distance-weighted average of the flow of the neighboring vascular segments. Fourth, we generated a series of bull's-eye maps of MP-SPECT images of different coronary artery stenosis scenarios. Fifth, we had expert physician readers to qualitatively assess the bull's-eye maps based on their similarity to typical clinical cases in terms of the shape, the extent, and the severity of the MPDs. Their input was used to iteratively revise the coronary artery tree model so that the MPDs were closely matched to those found in bull's-eye maps from patient studies. Finally, from our simulated MP-SPECT images, we observed that (1) the locations of the MPDs caused by stenoses at different main arteries were different largely according to their vascular territories, (2) a stenosis at a proximal branch produced a larger MPD than the one at a distal branch, and (3) a more severe stenosis produced a larger MPD than the less severe one. These observations were consistent to those found in clinical cases. Therefore, this new regional MPD model has enhanced the generation of realistic pathological MP-SPECT images using the XCAT phantom. When combining with the mechanical model of the myocardium, the new model can be extended for the simulation of 4D gated MP-SPECT simulation of a pathological heart with both perfusion and motion defects.

Entities:  

Year:  2010        PMID: 26535552      PMCID: PMC4603830          DOI: 10.1109/NSSMIC.2010.5874362

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  3 in total

1.  ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions.

Authors:  P J Scanlon; D P Faxon; A M Audet; B Carabello; G J Dehmer; K A Eagle; R D Legako; D F Leon; J A Murray; S E Nissen; C J Pepine; R M Watson; J L Ritchie; R J Gibbons; M D Cheitlin; T J Gardner; A Garson; R O Russell; T J Ryan; S C Smith
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

2.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

3.  Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models.

Authors:  Alexander I Veress; W Paul Segars; Jeffrey A Weiss; Benjamin M W Tsui; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

  3 in total
  4 in total

1.  The direct incorporation of perfusion defect information to define ischemia and infarction in a finite element model of the left ventricle.

Authors:  Alexander I Veress; George S K Fung; Taek-Soo Lee; Benjamin M W Tsui; Gregory A Kicska; W Paul Segars; Grant T Gullberg
Journal:  J Biomech Eng       Date:  2015-02-25       Impact factor: 2.097

2.  Design of a digital phantom population for myocardial perfusion SPECT imaging research.

Authors:  Michael Ghaly; Yong Du; George S K Fung; Benjamin M W Tsui; Jonathan M Links; Eric Frey
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

3.  Myocardial Blood Flow and Flow Reserve in Proximal and Mid-to-Distal Lesions of Left Anterior Descending Artery Measured By N-13 Ammonia PET/CT.

Authors:  Sang-Geon Cho; Ju Han Kim; Jae Young Cho; Hyeon Sik Kim; Hee-Seung Bom
Journal:  Nucl Med Mol Imaging       Date:  2013-05-22

4.  Computational Assessment of Blood Flow Heterogeneity in Peritoneal Dialysis Patients' Cardiac Ventricles.

Authors:  Sanjay R Kharche; Aaron So; Fabio Salerno; Ting-Yim Lee; Chris Ellis; Daniel Goldman; Christopher W McIntyre
Journal:  Front Physiol       Date:  2018-05-17       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.