Literature DB >> 20019401

The UF family of reference hybrid phantoms for computational radiation dosimetry.

Choonsik Lee1, Daniel Lodwick, Jorge Hurtado, Deanna Pafundi, Jonathan L Williams, Wesley E Bolch.   

Abstract

Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR. NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros. The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference organ masses from ICRP Publication 89, (3) reference elemental compositions provided in ICRP 89 as well as ICRU Report 46, and (4) reference data on the alimentary tract organs given in ICRP Publications 89 and 100. Various adjustments and refinements to the organ systems of the previously described newborn, 15 year and adult phantoms are also presented. The UF series of hybrid phantoms retain the non-uniform scalability of stylized phantoms while maintaining the anatomical realism of patient-specific voxel phantoms with respect to organ shape, depth and inter-organ distance. While the final versions of these phantoms are in a voxelized format for radiation transport simulation, their primary format is given as NURBS and polygon mesh surfaces, thus permitting one to sculpt non-reference phantoms using the reference phantoms as an anatomic template.

Entities:  

Mesh:

Year:  2009        PMID: 20019401      PMCID: PMC2800036          DOI: 10.1088/0031-9155/55/2/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods--RPI-P3, -P6 and -P9.

Authors:  X George Xu; Valery Taranenko; Juying Zhang; Chengyu Shi
Journal:  Phys Med Biol       Date:  2007-11-15       Impact factor: 3.609

2.  Skin thickness measurement by pulsed ultrasound: its reproducibility, validation and variability.

Authors:  C Y Tan; B Statham; R Marks; P A Payne
Journal:  Br J Dermatol       Date:  1982-06       Impact factor: 9.302

3.  Whole-body voxel phantoms of paediatric patients--UF Series B.

Authors:  Choonik Lee; Choonsik Lee; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2006-09-04       Impact factor: 3.609

Review 4.  Voxel-based computational models of real human anatomy: a review.

Authors:  Martin Caon
Journal:  Radiat Environ Biophys       Date:  2004-01-17       Impact factor: 1.925

5.  Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.

Authors: 
Journal:  Ann ICRP       Date:  2002

6.  Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models.

Authors:  Choonsik Lee; Daniel Lodwick; Deanna Hasenauer; Jonathan L Williams; Choonik Lee; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2007-05-16       Impact factor: 3.609

7.  Creation of two tomographic voxel models of paediatric patients in the first year of life.

Authors:  J C Nipper; J L Williams; W E Bolch
Journal:  Phys Med Biol       Date:  2002-09-07       Impact factor: 3.609

8.  The UF series of tomographic computational phantoms of pediatric patients.

Authors:  Choonik Lee; Jonathan L Williams; Choonsik Lee; Wesley E Bolch
Journal:  Med Phys       Date:  2005-12       Impact factor: 4.071

9.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

10.  Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry.

Authors:  Choonsik Lee; Daniel Lodwick; Jonathan L Williams; Wesley E Bolch
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

View more
  78 in total

1.  An approach for balancing diagnostic image quality with cancer risk: application to pediatric diagnostic imaging of 99mTc-dimercaptosuccinic acid.

Authors:  George Sgouros; Eric C Frey; Wesley E Bolch; Michael B Wayson; Andres F Abadia; S Ted Treves
Journal:  J Nucl Med       Date:  2011-12       Impact factor: 10.057

2.  Skin dose mapping for fluoroscopically guided interventions.

Authors:  Perry B Johnson; David Borrego; Stephen Balter; Kevin Johnson; Daniel Siragusa; Wesley E Bolch
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization.

Authors:  W P Segars; Hannah Norris; Gregory M Sturgeon; Yakun Zhang; Jason Bond; Anum Minhas; Daniel J Tward; J T Ratnanather; M I Miller; D Frush; E Samei
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

4.  Reduction in radiation doses from paediatric CT scans in Great Britain.

Authors:  Choonsik Lee; Mark S Pearce; Jane A Salotti; Richard W Harbron; Mark P Little; Kieran McHugh; Claire-Louise Chapple; Amy Berrington de Gonzalez
Journal:  Br J Radiol       Date:  2016-02-11       Impact factor: 3.039

5.  An image-based skeletal dosimetry model for the ICRP reference adult male--internal electron sources.

Authors:  Matthew Hough; Perry Johnson; Didier Rajon; Derek Jokisch; Choonsik Lee; Wesley Bolch
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

6.  Evaluation of the use of surrogate tissues for calculating radiation dose to lymphatic nodes from external photon beams.

Authors:  Stephanie Lamart; Brian E Moroz; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2013-07-11       Impact factor: 0.972

7.  Helium CT: Monte Carlo simulation results for an ideal source and detector with comparison to proton CT.

Authors:  Pierluigi Piersimoni; Bruce A Faddegon; José Ramos Méndez; Reinhard W Schulte; Lennart Volz; Joao Seco
Journal:  Med Phys       Date:  2018-05-20       Impact factor: 4.071

8.  Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient external anatomy.

Authors:  Michael B Wayson; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2018-04-13       Impact factor: 3.609

9.  Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient internal anatomy.

Authors:  Michael B Wayson; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2018-04-13       Impact factor: 3.609

10.  Synthetic breast phantoms from patient based eigenbreasts.

Authors:  Gregory M Sturgeon; Subok Park; William Paul Segars; Joseph Y Lo
Journal:  Med Phys       Date:  2017-10-19       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.