Literature DB >> 25395812

Simulation Evaluation of Quantitative Myocardial Perfusion Assessment from Cardiac CT.

Michael Bindschadler1, Dimple Modgil2, Kelley R Branch1, Patrick J La Riviere2, Adam M Alessio1.   

Abstract

Contrast enhancement on cardiac CT provides valuable information about myocardial perfusion and methods have been proposed to assess perfusion with static and dynamic acquisitions. There is a lack of knowledge and consensus on the appropriate approach to ensure 1) sufficient diagnostic accuracy for clinical decisions and 2) low radiation doses for patient safety. This work developed a thorough dynamic CT simulation and several accepted blood flow estimation techniques to evaluate the performance of perfusion assessment across a range of acquisition and estimation scenarios. Cardiac CT acquisitions were simulated for a range of flow states (Flow = 0.5, 1, 2, 3 ml/g/min, cardiac output = 3,5,8 L/min). CT acquisitions were simulated with a validated CT simulator incorporating polyenergetic data acquisition and realistic x-ray flux levels for dynamic acquisitions with a range of scenarios including 1, 2, 3 sec sampling for 30 sec with 25, 70, 140 mAs. Images were generated using conventional image reconstruction with additional image-based beam hardening correction to account for iodine content. Time attenuation curves were extracted for multiple regions around the myocardium and used to estimate flow. In total, 2,700 independent realizations of dynamic sequences were generated and multiple MBF estimation methods were applied to each of these. Evaluation of quantitative kinetic modeling yielded blood flow estimates with an root mean square error (RMSE) of ∼0.6 ml/g/min averaged across multiple scenarios. Semi-quantitative modeling and qualitative static imaging resulted in significantly more error (RMSE = ∼1.2 and ∼1.2 ml/min/g respectively). For quantitative methods, dose reduction through reduced temporal sampling or reduced tube current had comparable impact on the MBF estimate fidelity. On average, half dose acquisitions increased the RMSE of estimates by only 18% suggesting that substantial dose reductions can be employed in the context of quantitative myocardial blood flow estimation. In conclusion, quantitative model-based dynamic cardiac CT perfusion assessment is capable of accurately estimating MBF across a range of cardiac outputs and tissue perfusion states, outperforms comparable static perfusion estimates, and is relatively robust to noise and temporal subsampling.

Entities:  

Keywords:  CT Perfusion; Cardiac CT; Dynamic CT; Kinetic Modeling; Myocardial Blood Flow

Year:  2014        PMID: 25395812      PMCID: PMC4225804          DOI: 10.1117/12.2043563

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  9 in total

Review 1.  Perfusion CT: a worthwhile enhancement?

Authors:  K A Miles; M R Griffiths
Journal:  Br J Radiol       Date:  2003-04       Impact factor: 3.039

2.  Myocardial hypo-enhancement on resting computed tomography angiography images accurately identifies myocardial hypoperfusion.

Authors:  Joshua L Busch; Adam M Alessio; James H Caldwell; Mohit Gupta; Songshou Mao; Jigar Kadakia; William Shuman; Matthew J Budoff; Kelley R Branch
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-10-24

3.  Incremental value of myocardial perfusion over regional left ventricular function and coronary stenosis by cardiac CT for the detection of acute coronary syndromes in high-risk patients: a subgroup analysis of the ROMICAT trial.

Authors:  Hiram G Bezerra; Ricardo Loureiro; Thomas Irlbeck; Fabian Bamberg; Christopher L Schlett; Ian Rogers; Ron Blankstein; Quynh A Truong; Thomas J Brady; Ricardo C Cury; Udo Hoffmann
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-10-24

4.  Dynamic iterative beam hardening correction (DIBHC) in myocardial perfusion imaging using contrast-enhanced computed tomography.

Authors:  Philip Stenner; Bernhard Schmidt; Thomas Allmendinger; Thomas Flohr; Marc Kachelrie
Journal:  Invest Radiol       Date:  2010-06       Impact factor: 6.016

5.  Measurement of tissue perfusion by dynamic computed tomography.

Authors:  K A Miles
Journal:  Br J Radiol       Date:  1991-05       Impact factor: 3.039

6.  An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: I. Theoretical derivation.

Authors:  K S St Lawrence; T Y Lee
Journal:  J Cereb Blood Flow Metab       Date:  1998-12       Impact factor: 6.200

7.  Comparison of blood flow models and acquisitions for quantitative myocardial perfusion estimation from dynamic CT.

Authors:  Michael Bindschadler; Dimple Modgil; Kelley R Branch; Patrick J La Riviere; Adam M Alessio
Journal:  Phys Med Biol       Date:  2014-03-10       Impact factor: 3.609

8.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

9.  Quantitative tumor perfusion assessment with multidetector CT: are measurements from two commercial software packages interchangeable?

Authors:  Vicky Goh; Steve Halligan; Clive I Bartram
Journal:  Radiology       Date:  2007-03       Impact factor: 11.105

  9 in total
  1 in total

1.  [Redundancy information-induced image reconstruction for low-dose myocardial perfusion computed tomography].

Authors:  Jiahui Lin; Zhaoying Bian; Jianhua Ma; Jing Huang; Xi Tao; Dong Zeng; Hong Guo
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-01-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.