Literature DB >> 20953300

Multi-pinhole SPECT Imaging with Silicon Strip Detectors.

Todd E Peterson1, Sepideh Shokouhi, Lars R Furenlid, Donald W Wilson.   

Abstract

Silicon double-sided strip detectors offer outstanding instrinsic spatial resolution with reasonable detection efficiency for iodine-125 emissions. This spatial resolution allows for multiple-pinhole imaging at low magnification, minimizing the problem of multiplexing. We have conducted imaging studies using a prototype system that utilizes a detector of 300-micrometer thickness and 50-micrometer strip pitch together with a 23-pinhole collimator. These studies include an investigation of the synthetic-collimator imaging approach, which combines multiple-pinhole projections acquired at multiple magnifications to obtain tomographic reconstructions from limited-angle data using the ML-EM algorithm. Sub-millimeter spatial resolution was obtained, demonstrating the basic validity of this approach.

Entities:  

Year:  2009        PMID: 20953300      PMCID: PMC2953820          DOI: 10.1109/TNS.2009.2012514

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  10 in total

1.  Reconstruction of two- and three-dimensional images from synthetic-collimator data.

Authors:  D W Wilson; H H Barrett; E W Clarkson
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Photon penetration and scatter in micro-pinhole imaging: a Monte Carlo investigation.

Authors:  Frans van der Have; Freek J Beekman
Journal:  Phys Med Biol       Date:  2004-04-21       Impact factor: 3.609

3.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

4.  SemiSPECT: A Small-animal Imaging System Based on Eight CdZnTe Pixel Detectors.

Authors:  Todd E Peterson; Hyunki Kim; Michael J Crawford; Benjamin M Gershman; William C J Hunter; H Bradford Barber; Lars R Furenlid; Donald W Wilson; James M Woolfenden; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2002-11-10

5.  Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT.

Authors:  R J Jaszczak; J Li; H Wang; M R Zalutsky; R E Coleman
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

6.  Resolution- versus sensitivity-effective diameter in pinhole collimation: experimental verification.

Authors:  S D Metzler; R Accorsi
Journal:  Phys Med Biol       Date:  2005-10-12       Impact factor: 3.609

7.  Photon-counting versus an integrating CCD-based gamma camera: important consequences for spatial resolution.

Authors:  Freek J Beekman; Gerralt A de Vree
Journal:  Phys Med Biol       Date:  2005-05-25       Impact factor: 3.609

8.  Design and Feasibility Study of a Single Photon Emission Microscope System for Small Animal I-125 Imaging.

Authors:  L J Meng; N H Clinthorne; S Skinner; R V Hay; M Gross
Journal:  IEEE Trans Nucl Sci       Date:  2006-06-26       Impact factor: 1.679

9.  U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice.

Authors:  Freek J Beekman; Frans van der Have; Brendan Vastenhouw; Annemarie J A van der Linden; Peter P van Rijk; J Peter H Burbach; Marten P Smidt
Journal:  J Nucl Med       Date:  2005-07       Impact factor: 10.057

10.  Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals.

Authors:  D A Weber; M Ivanovic; D Franceschi; S E Strand; K Erlandsson; M Franceschi; H L Atkins; J A Coderre; H Susskind; T Button
Journal:  J Nucl Med       Date:  1994-02       Impact factor: 10.057

  10 in total
  7 in total

1.  High-Resolution Anamorphic SPECT Imaging.

Authors:  Heather L Durko; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2014-06       Impact factor: 1.679

2.  Evaluation of image reconstruction for mouse brain imaging with synthetic collimation from highly multiplexed SiliSPECT projections.

Authors:  S Shokouhi; D W Wilson; S D Metzler; T E Peterson
Journal:  Phys Med Biol       Date:  2010-08-16       Impact factor: 3.609

3.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

4.  Design and performance of a small-animal imaging system using synthetic collimation.

Authors:  R J Havelin; B W Miller; H H Barrett; L R Furenlid; J M Murphy; R M Dwyer; M J Foley
Journal:  Phys Med Biol       Date:  2013-04-26       Impact factor: 3.609

5.  Reducing multiplexing artifacts in multi-pinhole SPECT with a stacked silicon-germanium system: a simulation study.

Authors:  Lindsay C Johnson; Sepideh Shokouhi; Todd E Peterson
Journal:  IEEE Trans Med Imaging       Date:  2014-07-17       Impact factor: 10.048

6.  Molecular Imaging in the College of Optical Sciences - An Overview of Two Decades of Instrumentation Development.

Authors:  Lars R Furenlid; Harrison H Barrett; H Bradford Barber; Eric W Clarkson; Matthew A Kupinski; Zhonglin Liu; Gail D Stevenson; James M Woolfenden
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-08-17

7.  Gamma Radiation Imaging System via Variable and Time-Multiplexed Pinhole Arrays.

Authors:  Ariel Schwarz; Amir Shemer; Yossef Danan; Rachel Bar-Shalom; Hemy Avraham; Alex Zlotnik; Zeev Zalevsky
Journal:  Sensors (Basel)       Date:  2020-05-26       Impact factor: 3.576

  7 in total