Photon penetration and scatter in micro-pinhole imaging: a Monte Carlo investigation.

Frans van der Have1, Freek J Beekman.   

Abstract

Pinhole SPECT is rapidly gaining popularity for imaging laboratory animals using gamma-emitting molecules. Penetration and scattering of gamma radiation in the pinhole edge material can account for a significant fraction of the total number of photons detected, particularly if the pinholes have small diameters. This study characterizes the effects of penetration and scatter with micro-pinholes made of lead, tungsten, gold and platinum. Monte Carlo simulations are performed for 1-125 (27-35 keV) and Tc-99m (140 keV) point sources with pinhole diameters ranging from 50 to 500 microm. The simulations account for the effects of photo-electric interaction, Rayleigh scattering, Compton scattering, ionization, bremsstrahlung and electron multiple scattering. As a typical example, in the case of a Tc-99m point source and pinholes with a diameter of 300 microm in gold or platinum, approximately 55% of the photons detected resulted from penetration and approximately 3% from scatter. For pinhole diameters ranging from 100 to 500 microm, the penetration fraction for tungsten and lead was approx a factor of 1.0 to 1.6 higher and the scatter fraction was 1.0 to 1.8 times higher than in case of gold or platinum. Using I-125 instead of Tc-99m decreases the penetration fraction by a factor ranging from 3 to 11 and the scatter fraction by a factor ranging from 12 to 40. For all materials studied, the total amounts of penetrated and scattered photons changed approximately linearly with respect to the pinhole diameter.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15152680     DOI: 10.1088/0031-9155/49/8/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  A Vector Uniform Cramer-Rao Bound for SPECT System Design.

Authors:  Ling-Jian Meng; Nan Li
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

2.  Multi-energy, single-isotope imaging using stacked detectors.

Authors:  B S McDonald; S Shokouhi; H H Barrett; T E Peterson
Journal:  Nucl Instrum Methods Phys Res A       Date:  2007-08-21       Impact factor: 1.455

3.  Absolute quantitative total-body small-animal SPECT with focusing pinholes.

Authors:  Chao Wu; Frans van der Have; Brendan Vastenhouw; Rudi A J O Dierckx; Anne M J Paans; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-25       Impact factor: 9.236

4.  Multi-pinhole SPECT Imaging with Silicon Strip Detectors.

Authors:  Todd E Peterson; Sepideh Shokouhi; Lars R Furenlid; Donald W Wilson
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

5.  Joint Optimization of Collimator and Reconstruction Parameters in X-Ray Fluorescence Computed Tomography Using Analytical Point Spread Function and Model Observer.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Sang Hyun Cho; Andrew Karellas
Journal:  IEEE Trans Biomed Eng       Date:  2019-12-30       Impact factor: 4.538

Review 6.  Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging.

Authors:  Jalil Pirayesh Islamian; AhmadReza Azazrm; Babak Mahmoudian; Esmail Gharapapagh
Journal:  World J Nucl Med       Date:  2015 Jan-Apr

Review 7.  The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI.

Authors:  Monique R Bernsen; Pieter E B Vaissier; Roel Van Holen; Jan Booij; Freek J Beekman; Marion de Jong
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05       Impact factor: 9.236

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.