Literature DB >> 21959828

Arterial flow characteristics in the presence of vascular disease and implications for fast spin echo-based noncontrast MR angiography.

Pippa Storey1, Ruth P Lim, Sooah Kim, David R Stoffel, Vivian S Lee.   

Abstract

PURPOSE: To investigate arterial flow characteristics in the setting of vascular disease, and examine their effect on the performance of fast spin-echo (FSE)-based noncontrast MR angiography (NC-MRA).
MATERIALS AND METHODS: Seventeen patients were recruited from among those scheduled for routine contrast-enhanced MR angiography (CE-MRA) of the lower extremities at 1.5 Tesla. The research portion of the exam was performed before the clinically-indicated protocol and included phase-contrast imaging at multiple levels in the legs and FSE-based NC-MRA in the calf and thigh, using a three-dimensional ECG-gated technique that exploits differences in arterial flow velocity between diastole and systole.
RESULTS: Vascular occlusions were associated with reduced systolic velocity, a delayed systolic peak, and, in two middle-aged patients, an increase in diastolic velocity. Elevated systolic and diastolic velocities were observed in a subject with a nonhealing ulcer. NC-MRA allowed visualization of arteries with systolic velocities as low as 3 cm/s, and exhibited comparable depiction to CE-MRA for diastolic velocities as high as 6 cm/s. At the highest diastolic velocities observed (15 cm/s) arterial depiction was severely degraded.
CONCLUSION: FSE-based NC-MRA as presently implemented performs successfully over a wide range of flow patterns, but does not accommodate extremely low systolic velocities or very high diastolic velocities.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21959828      PMCID: PMC3221815          DOI: 10.1002/jmri.22812

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  16 in total

1.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

2.  Fresh blood imaging of the peripheral vasculature: an emerging unenhanced MR technique.

Authors:  Edward T D Hoey; Arul Ganeshan; Rakesh Puni; John Henderson; Paul M Crowe
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

3.  Noncontrast-enhanced peripheral MRA: technical optimization of flow-spoiled fresh blood imaging for screening peripheral arterial diseases.

Authors:  Katsumi Nakamura; Mitsue Miyazaki; Kiyomi Kuroki; Akiyoshi Yamamoto; Akihiro Hiramine; Faiza Admiraal-Behloul
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

4.  Tailoring the flow sensitivity of fast spin-echo sequences for noncontrast peripheral MR angiography.

Authors:  Pippa Storey; Iliyana P Atanasova; Ruth P Lim; Jian Xu; Daniel Kim; Qun Chen; Vivian S Lee
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

Review 5.  Magnetic resonance angiography for the evaluation of lower extremity arterial disease: a meta-analysis.

Authors:  M J Koelemay; J G Lijmer; J Stoker; D A Legemate; P M Bossuyt
Journal:  JAMA       Date:  2001-03-14       Impact factor: 56.272

6.  Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: Technical considerations and clinical feasibility.

Authors:  Robert R Edelman; John J Sheehan; Eugene Dunkle; Nancy Schindler; James Carr; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

7.  Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography.

Authors:  Ting Song; Andrew F Laine; Qun Chen; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Gerhard Laub; Randall Kroeker; Vivian S Lee
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

8.  3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP.

Authors:  Zhaoyang Fan; John Sheehan; Xiaoming Bi; Xin Liu; James Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

9.  Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo.

Authors:  Reed F Busse; Anja C S Brau; Anthony Vu; Charles R Michelich; Ersin Bayram; Richard Kijowski; Scott B Reeder; Howard A Rowley
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

Review 10.  Gadolinium and nephrogenic systemic fibrosis.

Authors:  T Grobner; F C Prischl
Journal:  Kidney Int       Date:  2007-05-16       Impact factor: 10.612

View more
  4 in total

1.  Comparison of nonenhanced MR angiographic subtraction techniques for infragenual arteries at 1.5 T: a preliminary study.

Authors:  Ruth P Lim; Zhaoyang Fan; Manjil Chatterji; Amanjit Baadh; Iliyana P Atanasova; Pippa Storey; Danny C Kim; Sooah Kim; Philip A Hodnett; Afhsan Ahmad; David R Stoffel; James S Babb; Mark A Adelman; Jian Xu; Debiao Li; Vivian S Lee
Journal:  Radiology       Date:  2013-01-07       Impact factor: 11.105

2.  High-permittivity thin dielectric padding improves fresh blood imaging of femoral arteries at 3 T.

Authors:  Marc D Lindley; Daniel Kim; Glen Morrell; Marta E Heilbrun; Pippa Storey; Christopher J Hanrahan; Vivian S Lee
Journal:  Invest Radiol       Date:  2015-02       Impact factor: 6.016

3.  Sagittal fresh blood imaging with interleaved acquisition of systolic and diastolic data for improved robustness to motion.

Authors:  Iliyana P Atanasova; Daniel Kim; Pippa Storey; Andrew B Rosenkrantz; Ruth P Lim; Vivian S Lee
Journal:  Magn Reson Med       Date:  2013-01-08       Impact factor: 4.668

4.  Detection of infragenual arterial disease using non-contrast-enhanced MR angiography in patients with diabetes.

Authors:  Xin Liu; Na Zhang; Zhaoyang Fan; Fei Feng; Qi Yang; Hairong Zheng; Pengcheng Liu; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2013-11-08       Impact factor: 4.813

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.