Literature DB >> 22714282

Optimization of 3D-variable refocusing flip angle RARE imaging for high-resolution volumetric black-blood angiography.

Masami Yoneyama1, Masanobu Nakamura, Takashi Tabuchi, Atsushi Takemura, Makoto Obara.   

Abstract

3D rapid acquisition with relaxation enhancement or turbo spin-echo sequence is promising for black-blood angiography. In this paper, we propose a new scheme of sequence parameter optimization for "flow-void enhanced" volumetric black-blood angiography. Although black-blood imaging has numerous applications, we focused on the carotid artery in this study. All experiments were performed on a 3.0-T imager. The methods used were a flow phantom study and a volunteer study. From the results, the optimal parameters for black-blood angiography were the use of very-low refocusing flip angles, use of a "90° + α/2" refocusing flip angle sweep, and "flow sensitization" at the "in-plane flow" situational imaging plane. This sequence can be used for 3D volumetric black-blood angiography and vessel wall imaging.

Mesh:

Year:  2012        PMID: 22714282     DOI: 10.1007/s12194-012-0161-6

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  10 in total

1.  Easy improvement of signal-to-noise in RARE-sequences with low refocusing flip angles. Rapid acquisition with relaxation enhancement.

Authors:  J Hennig; K Scheffler
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

2.  Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).

Authors:  Juergen Hennig; Matthias Weigel; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

Review 3.  Factors influencing contrast in fast spin-echo MR imaging.

Authors:  R T Constable; A W Anderson; J Zhong; J C Gore
Journal:  Magn Reson Imaging       Date:  1992       Impact factor: 2.546

4.  Tailoring the flow sensitivity of fast spin-echo sequences for noncontrast peripheral MR angiography.

Authors:  Pippa Storey; Iliyana P Atanasova; Ruth P Lim; Jian Xu; Daniel Kim; Qun Chen; Vivian S Lee
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

5.  Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.

Authors:  Reed F Busse; Hari Hariharan; Anthony Vu; Jean H Brittain
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

Review 6.  Imaging artifacts at 3.0T.

Authors:  Matt A Bernstein; John Huston; Heidi A Ward
Journal:  J Magn Reson Imaging       Date:  2006-10       Impact factor: 4.813

7.  T1-weighted-SPACE dark blood whole body magnetic resonance angiography (DB-WBMRA): initial experience.

Authors:  Georgeta Mihai; Yiu-Cho Chung; Ali Merchant; Orlando P Simonetti; Sanjay Rajagopalan
Journal:  J Magn Reson Imaging       Date:  2010-02       Impact factor: 4.813

8.  Intracranial black-blood MR angiography with high-resolution 3D fast spin echo.

Authors:  A L Alexander; H R Buswell; Y Sun; B E Chapman; J S Tsuruda; D L Parker
Journal:  Magn Reson Med       Date:  1998-08       Impact factor: 4.668

9.  The sensitivity of low flip angle RARE imaging.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-02       Impact factor: 4.668

10.  Gradient moment nulling in fast spin echo.

Authors:  R S Hinks; R T Constable
Journal:  Magn Reson Med       Date:  1994-12       Impact factor: 4.668

  10 in total
  5 in total

1.  Simple method for whole-brain volumetric T(1)-weighted turbo spin-echo imaging.

Authors:  Masami Yoneyama; Masanobu Nakamura; Makoto Obara; Takashi Namiki; Atsushi Takemura; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-12-04

2.  Reevaluation of T2-weighted fast field echo (T2FFE): application to rapid volumetric black-blood imaging.

Authors:  Masami Yoneyama; Masanobu Nakamura; Takashi Tabuchi; Takashi Namiki; Atsushi Takemura; Makoto Obara
Journal:  Radiol Phys Technol       Date:  2013-02-16

3.  Whole-brain black-blood imaging with magnetization-transfer prepared spin echo-like contrast: a novel sequence for contrast-enhanced brain metastasis screening at 3T.

Authors:  Masami Yoneyama; Masanobu Nakamura; Takashi Tabuchi; Atsushi Takemura; Makoto Obara; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-05-05

4.  Characterization of lenticulostriate arteries with high resolution black-blood T1-weighted turbo spin echo with variable flip angles at 3 and 7 Tesla.

Authors:  Samantha J Ma; Mona Sharifi Sarabi; Lirong Yan; Xingfeng Shao; Yue Chen; Qi Yang; Kay Jann; Arthur W Toga; Yonggang Shi; Danny J J Wang
Journal:  Neuroimage       Date:  2019-05-31       Impact factor: 7.400

5.  Pitfall for systemic artery aneurysms evaluation using electrocardiogram-gated subtracted three-dimensional fast spin echo sequence of magnetic resonance imaging in patients with Kawasaki disease.

Authors:  Haruki Nonaka; Takanori Masuda; Masami Yoneyama; Masahiro Tahara; Mio Okano; Yuko Morikawa; Kazuya Sanada; Tomoyasu Sato
Journal:  Radiol Case Rep       Date:  2022-03-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.